Project Name        : FMBXXX
=================================================================================
---------------------------------------------------------------------------------
DATE:       - VER:              - A:    -  JIRA :    - CHANGES:
--------------------------------------------------------------------------------
2026.04.16  - E.OBDRefine_R.2   - JL    - FMBP-55636 - Release:
                                - JL    - FMBP-54876 - feat: add OBD IO sending options
2026.03.16  - E.OBDRefine_R.1   - JL    - FMBP-55182 - Release:
                                - JL    - FMBP-55178 - feat: BU to 04.02.00.Rev.10
2025.12.16  - E.OBD_Fixes_R.19  - JL    - FMBP-53942 - Release:
                                - ViPe  - FMBP-52920 - feat: Split oem and calc remaining distance
2025.11.19  - E.OBD_Fixes_R.18  - JL    - FMBP-53437 - Release:
                                - JL    - FMBP-53207 - feat: Removing Ignition Monitoring
2025.11.06  - E.OBD_Fixes_R.17  - JL    - FMBP-52904 - Release:
                                - JL    - FMBP-52726 - feat: EV Charge monitoring
2025.09.25  - E.OBD_Fixes_R.16  - JL    - FMBP-52361 - Release:
                                - JL    - FMBP-51894 - feat: add ELD Engine minutes
2025.09.25  - E.OBD_Fixes_R.15  - JL    - FMBP-52361 - Release:
                                - JL    - FMBP-52336 - feat: configurator update after BU to 04.02
2025.08.13  - E.OBD_Fixes_R.14  - ViPe  - FMBP-51551 - Release:
                                - JL    - FMBP-51490 - feat: configurator update after BU
2025.07.02  - E.OBD_Fixes_R.13  - JL    - FMBP-50741 - Release:
                                - JL    - FMBP-50741 - fix: token fix (5db12949)
                                - JL    - FMBP-50479 - feat: adding ignition source operand
                                - JL    - FMBP-46842 - fix: adding altelium spec features to configurator
2024.11.11  - E.OBD_Fixes_R.12  - YM    - FMBP-46110 - Release:
                                - YM    - FMBP-45759 - feat: spec 206 (Altelium) merge
                                - MA    - FMBP-43584 - fix: missing or wrong Localizations
                                - ViPe  - FMBP-45842 - feat: Added OEM Distance Since Refuel
2024.09.30  - E.OBD_Fixes_R.11  - YM    - FMBP-45566 - Release:
                                - YM    - FMBP-45613 - feat: OEM battery power consumption parameter removed
2024.09.26  - E.OBD_Fixes_R.10  - YM    - FMBP-45566 - Release:
                                - YM    - FMBP-44826 - fix: ELD feature added
2024.08.30  - E.OBD_Fixes_R.09  - YM    - FMBP-44967 - Release:
                                - YM    - FMBP-44826 - fix: TSK can't download configuration
2024.08.07  - E.OBD_Fixes_R.08  - YM    - FMBP-44533 - Release:
                                - YM    - FMBP-44109 - feat: hide unnecessary EV parameters
                                - YM    - FMBP-43944 - feat: merge OBD branches (eld-feature, obd-new)
2024.07.19  - E.OBD_Fixes_R.07  - YM    - FMBP-43248 - Release:
                                - YM    - FMBP-43248 - fix: CI scripts for branding
2024.07.18  - E.OBD_Fixes_R.06  - YM    - FMBP-43248 - Release:
                                - JV    - FMBP-42669 - fix: Added LTE bands and connectivity info for FMC003
2024.05.10  - E.OBD_Fixes_R.05  - YM    - FMBP-40819 - Release:
                                - ViPe  - FMBP-41603 - fix: Duplicate parameters IO. Connectivity Quality and Current LTE BAND
                                - KrBa  - FMBP-41536 - feat: Merge ignition off delay for FMx00A
                                - ViPe  - FMBP-41182 - fix: return function averaging OBD parameter fuel level
2024.03.07  - E.OBD_Fixes_R.04  - KrBa  - FMBP-40466 - Release:
                                - JV    - FMBP-39400 - fix: Limit connection errors duplicate removed
                                - JV    - FMBP-39400 - feat: merge fmb150dev into expfw/obd-fixes
                                - JV    - FMBP-32786 - fix: Added OEM power consumption parameter and tooltip
2023.10.02  - E.OBD_Fixes_R.03  - ViPe  - FMBP-37741 - Release:
                                - ViPe  - FMBP-37838 - fix: added obd fuel level avg
2023.10.02  - E.OBD_Fixes_R.02  - JF    - FMBP-36050 - Release:
                                - JF    - FMBP-35629 - fix: current lte band average
2023.07.31  - E.OBD_Fixes_R.01  - YM    - FMBP-34879 - Release:
                                - YM    - FMBP-34684 - feat: merge quectel-data-sending branch
                                - YM    - FMBP-34684 - feat: merge pap-chap-obd branch
                                - YM    - FMBP-34684 - feat  merge OBD_OEM-Green_Driving branch
                                - YM    - FMBP-34684 - feat: merge 3.29_R.07 to obd-fixes branch
2023.11.21  - B.3.29_R.11       - MA    - FMBP-37499 - Release:
                                - AO    - FMBP-36767 - fix: virtual din2 exists for FMB910 but not on configurator
2023.10.13  - B.3.29_R.10       - MA    - FMBP-36220 - Release:
                                - PK    - FMBP-35601 - feat: added Ruuvi_RAWv2 sensor preset
                                - MA    - FMBP-36393 - fix: EYE IO display current value.
                                - AN    - FMBP-36267 - fix: remove devices that do not support connectivity I/O
2023.09.15  - B.3.29_R.09       - MA    - FMBP-36070 - Release:
                                - MA    - FMBP-35518 - fix: add missing SFF IO description and changed names for EYE sensor IOs
                                - MA    - FMBP-35818 - fix: enabled axl gravity filter and calibration IO element for FMx0 devices
                                - AO    - FMBP-35276 - fix: default apn to empty string
                                - KrBa  - FMBP-35791 - feat: merged IO and options from E.Q-fixes_R.04
                                - MA    - FMBP-35663 - fix: backup tracker parameter visibility when eye beacon functionality enabled
2023.08.02  - B.3.29_R.08       - LR    - FMBP-34902 - Release:
                                - AO    - FMBP-34511 - fix: Changed offline default of Sleep mode to Online Deep Sleep
2023.06.05  - B.3.29_R.07       - MA    - FMBP-33775 - Release:
                                - MA    - FMBP-32533 - fix: remove BT HF selection for FMM13A, FMM130(M3), FMM125(M3), FMM230(M3)
                                - MA    - FMBP-33227 - fix: dout control via call availability on HW
                                - ArS   - FMBP-33400 - fix: DOUT ON duration max value mismatch
                                - ArS   - FMBP-29480 - fix: backup tracker and BT/BLE settings dependencies, source upd to 1.7.69
2023.05.08  - B.3.29_R.06       - MA    - FMBP-32984 - Release:
                                - MA    - CONF-2841  - upd: configurator source to 1.7.68
                                - ArS   - FMBP-32552 - fix: missing DOUT control via call for FMM bg95m3
                                - MA    - FMBP-32641 - fix: OEM Distance Until Service low level min value
                                - MA    - FMBP-32533 - fix: BT connection modes for various HWs
                                - MA    - FMBP-32532 - fix: missing ibutton option for fmm13a autogeofencing
                                - KL    - FMBP-30434 - fix: add LVCAN RSF and Road signs IO elements.
                                - MA    - FMBP-32163 - fix: FMC225 with single DIN frequency io
                                - MA    - FMBP-32131 - fix: config for FMC125 wrong DOUT count on ibutton notification feature
2023.04.14  - B.3.29_R.05       - MA    - FMBP-32260 - Release:
                                - MA    - FMBP-32084 - fix: OBDII selection on BT mode for few HW
                                - MA    - FMBP-32104 - fix: return removed hws by mistake
                                - MA    - FMBP-32163 - fix: DIN frequency IOs for renamed HWs
                                - MA    - FMBP-32075 - fix: missing UDS option in sleep settings
                                - MA    - FMBP-32105 - fix: DeactivationBy param for FMx130 devices
                                - MA    - FMBP-32094 - fix: can control config for FMM125
                                - MA    - FMBP-32123 - fix: removed OBDII settings for non-OBD devices
                                - MA    - FMBP-32183 - fix FMB140 config after removing EOS HW
                                - MA    - FMBP-32106 - fix: duplicate params in OBDII tab and optimization
                                - PK    - FMBP-31829 - fix: can adapter current value
2023.03.31  - B.3.29_R.04       - MA    - FMBP-31992 - Release:
                                - MK    - FMBP-29480 - upd: configurator-source to hide BLE discover on backup
                                - MA    - FMBP-31531 - fix: default config change and optimizations
                                - MA    - FMBP-31888 - ref: removed EOS hw config support/optimization after remove
                                - MA    - FMBP-31659 - fix: advanced pulse counter config
                                - MA    - FMBP-31532 - ref: On Demand activators rework/added missing config for FMB140/240
                                - MA    - FMBP-31471 - fix: ble connectionless configuration for different versions
                                - MA    - FMBP-31458 - fix: OEM reset button for FMM003 BG95M3
                                - ArS   - FMBP-31116 - fix: restored missing autoanswer selection in call settings for FMB
                                - MA    - FMBP-31238 - fix: remove auto-calibration selection for OBD/FMP100 units
2023.03.13  - B.3.29_R.03       - MA    - FMBP-30701 - Release:
                                - MA    - FMBP-30234 - fix: missing OEM reset button for FMC003/FMM003
                                - MA    - FMBP-30232 - fix: missing parameters changes for FMM003 M1/M3 HWs
                                - ArS   - FMBP-31116 - fix: restored missing autoanswer selection in call settings
                                - MA    - FMBP-31136 - fix: Advanced pulse counter selection for FMM130 BG95M3
                                - AO    - FMBP-30162 - fix: online-offline defaults mismatching for some parameters
                                - MA    - FMBP-31047 - fix: parameter option selection by HW attributes for several HWs
                                - ArS   - FMBP-30682 - feat(codec): changed codec default version to Codec8 Extended, from 10.0.0 version
                                - KV    - FMBP-11247 - fix: changed max length of server domain from 55 to 60 and added missing dout control via ignition options
2023.02.27  - B.3.29_R.02       - MA    - FMBP-30168 - Release:
                                - ViPe  - FMBP-30315 - fix: names of OEM parameters are not visible
                                - MK    - FMBP-29480 - fix: visible ble configuration when backup tracker is enabled
2023.02.03  - B.3.29_R.01       - MA    - FMBP-29451 - Release:
                                - JZ    - FMBP-29321 - feat: Ported sms rework from 03.28.07.Rev.103
                                - GKa   - FMBP-29357 - fix: SLM320 jamming support fixes
                                - JS    - FMBP-26955 - feat: FMC13A_FMM13A_HW_Support
                                - FS    - FMBP-29320 - fix: FMC9/FMM9 HW support version
                                - PK    - FMBP-24815 - fix: changed max val of Bale IOs LowLevel
                                - FS    - FMBP-29320 - feat: FMC9/FMM9 HW support
                                - MK    - FMBP-29480 - fix: sensor parameter visibility when backup tracker is enabled
                                - AO    - FMBP-28720 - fix: Updated configurator source to 1.7.62
                                - AO    - FMBP-27539 - fix: 1113 and 1100 limiting values
                                - AO    - FMBP-27946 - fix: panic tooltips
                                - MK    - FMBP-1109  - fix: towing event timeout parameter values
                                - AO    - FMBP-28747 - fix: network jamming parameter limits
                                - MK    - FMBP-19393 - fix: eye sensor name list tool tips
                                - MK    - FMBP-15921 - fix: eye beacon name list tool tips
                                - AJ    - FMBP-29358 - feat: FMX00X branch changes into develop
2022.12.09  - B.3.28_R.13       - MA    - FMBP-28068 - Release:
                                - MA    - FMBP-28347 - fix: beacon configuration missing addition beacon data configuration
2022.11.07  - B.3.28_R.12       - JZ    - FMBP-27318 - Release:
                                - MA    - FMBP-24285 - [MRG] BTX with autocalibration to base
                                - ArS   - FMBP-22712 - [ADD] BT/BLE off and pwu during sleep ported to base
                                - ArS   - FMBP-21601 - [FIX] HW type naming for FMB100/110 and FMB120/122
                                - KV    - FMBP-21588 - [FIX] Business Mode Start/End Time max values don't match FW
                                - KV    - FMBP-24123 - [FIX] Added min, max, default values for no movement timeout tooltip
                                - MA    - FMBP-24617 - [FIX] Branding HW attributes for Morey
                                - RJ    - FMBP-21607 - [FIX] Tooltip for panic priority
                                - RJ    - FMBP-21837 - [FIX] Jamming dout on/off max val
2022.10.21  - B.3.28_R.11       - MA    - FMBP-26723 - Release:
                                - KV    - FMBP-26401 - Missing can adapter section in certain devices
2022.10.07  - B.3.28_R.10       - MA    - FMBP-25223 - Release:
                                - KV    - FMBP-24775 - [FIX] Backup tracker visibility
2022.09.09  - B.3.28_R.09       - MA    - FMBP-24620 - Release:
                                - MA    - FMBP-24877 - [FIX] remove HW declaration from older config version to fix support on newer version
2022.08.16  - B.3.28_R.08       - LR    - FMBP-23855 - Release:
                                - RJ	- FMBP-17270 - [FIX] FMB910 picture
2022.07.29  - B.3.28_R.07       - JZ    - FMBP-23799 - Release:
                                - KL    - FMBP-22502 - [FIX] Porting missing DIN Mode and DOUT Control parameters to private mode
                                - KV	- FMBP-23282 - [FIX] Added default values for DOUT via call
                                - Ars   - FMBP-19994 - [ADD] TAT100 backup tracker (E.3.27_R.75)
                                - ES    - FMBP-21892 - [UPD] Default IOT Network mode has been changed
                                - ABa   - FMBP-12306 - [MRG] Merge 03.28.00.Rev.107 into develop
                                                       - Add lvcan features (state flags, send options...)
                                - MA    - CONF-1421  -  [ADD] CI/CD changes for configuration formating.
2022.05.13  - B.3.28_R.06       - MA    - FMBP-19877 -  Release:
                                - MA    - FMBP-19995 -  [FIX] Min/Max for Time params
                                - MA    - FMBP-20783 -  [FIX] Remove duplicated HWs configs
                                - MA    - FMBP-20691 -  [FIX] GNSS jamming feature configuration for all HWs.
                                - DL    - FMBP-19131 -  [ADD] RS232 save to IO
                                - GKa   - FMBP-19876 -  [ADD] SLM320 jamming support
                                - ABa   - FMBP-19878 -  [MGR] FMB003 branch updates to base:
                                                              - New HWs: BG95M1/M3 support
                                                              - SpecIDs features: 135, 171
                                                              - Fuel level AVG features, OEM IO params and VIN configuration
                                                              - CFG online offline mismatch fix
                                - MJ    - CONF-1521  -  [ADD] CI/CD changes to archive Configurator with .NET runtime
2022.03.30  - B.3.28_R.05       - JZ    - FMBP-19707 -  Release:
                                - GKa   - FMBP-19346 -  [ADD] FMB140 support for SpecId138
                                - JR    - FMBP-19126 -  [UPD] Change "Buzzer" button type in "User Interface" section in Configurator
                                - JR    - FMBP-14332 -  [FIX] Too many possible values for FMP100 UI parameters
                                - IN    - FMBP-18816 -  [ADD] Panic Button sensor preset
                                - VBe   - FMBP-13650 -  [MRG] Pulse counter rework
                                - ArS   - FMBP-18351 -  [ADD] Created ReadMe.md file for gitlab
2022.02.25  - B.3.28_R.04       - JZ    - FMBP-18154 -  Release:
                                - MA    - FMBP-18109 -  [FIX] DIN3 as Ignition source for HWs with DIN3
                                - MA    - FMBP-15371 -  [FIX] description of ignition source param
                                - MA    - FMBP-14449 -  [FIX] default values
                                - KrBa  - FMBP-14524 -  [ADD] Radius SpecID152
                                - JZ    - FMBP-18130 -  [MRG] Virtual DIN2 from 03.25.15.Rev.251
                                - VBe   - FMBP-16219 -  [ADD] RS485 buffered support
                                - IN    - FMBP-16106 -  [ADD] Fantom sensor preset
                                - PK    - FMBP-2439  -  [ADD] 1-wire DS, ODS parameter
2022.02.11  - B.3.28_R.03       - JZ    - FMBP-17294 -  Release:
                                - JS    - FMBP-4427  -  [ADD] SupportLow Power Mode (LPM)
                                - IN    - FMBP-5629  -  [ADD] Support 16 LLS sensors
                                - PK    - FMBP-1242  -  [ADD] SECO functionality to 03.28.xx base
                                - MA    -            -  [UPD] Configurator source to 1.7.38
                                - MA    - FMBP-16279 -  [REM] FMP100 autocalibration feature
                                - IN    - FMBP-13617 -  [FIX] Advanced beacon source tooltip
                                - JB    - CONF-684   -  Updated with ConfigurationFileUpdater
                                - JS    - FMBP-15014 -  [ADD] Spec ID 172 (Ctrack) support to 03.28.xx base
2021.11.12  - B.3.28_R.02       - LR    - FMBP-14758 -  Release:
                                - JB    - FMBP-14257 -  [FIX] Spec 151 missing 2009 parameter
                                - JB    - FMBP-14993 -  [ADD] Added spec 102 additional support
                                - AAg   - FMBP-14575 -  [UPD] Configurator Source to 1.7.30
                                - ArS   - FMBP-12902 -  [UPD] Localization submodule update to the newest 03.28.xx
                                - BS    - FMBP-12363 -  [UPD] Branding submodule
                                - JZ    - FMBP-13834 -  [FIX] Duplicate DOUT1 IO
2021.10.01  - B.3.28_R.01       - LR    - FMBP-12886 -  Release:
                                - LR                 -  [UPD] Configurator Source to 1.7.29
                                - JZ    - FMBP-13905 -  [FIX] ServiceBus duplicate parameters for spec 151
                                - BS    - FMBP-13833 -  [FIX] BLE fuel level + frequency visibility on FMB140
                                - VBe   - FMBP-13316 -  [FIX] LVCAN Oil level
                                - JŽ    - FMBP-13512 -  [ADD] Private/Business functionality to other HWs
                                - JŽ    -            -  [UPD] Configurator Source to 1.7.27
                                - MA    - FMBP-12484 -  [FIX] missing base params for FMU120/FMU122
                                - MA    - FMBP-1469  -  [FIX] missing instant movement IO element
                                - MA    - FMBP-12779 -  [FIX] FMB207 configurator crash
                                - KrBa  - FMBP-12152 -  Added SpecID171 support
                                - MA    - FMBP-12668 -  [FIX] IO's High/Low level ranges.
                                - ZG    - FMBP-12691 -  Added OEM IO params and VIN configuration
2021.06.23  - B.3.28_R.00       - KiBo  - FMBP-3354  -  Release:
                                - KiBo  - FMBP-12057 -  Merged develop + 03.27.xx + FMB003 + FMP100 branches
                                                        New HWs: FMB003, FMB002, FMB020, FMP100
                                                        New SPECs: 135, 171, 157, 151
                                - ArS   - FMBP-11759 -  [FIX] Moved BLE feature check
                                - JB    - CONF-148   -  [ADD] Added Gree/eco driving calculation
                                - ArS   - FMBP-9143  -  [FIX] Moved RS232 description ending
2021.10.29  - B.3.27_R.26       - LR    - FMBP-14861 -  Release:
                                - JB    - FMBP-14757 -  [ADD] Missing BLE Fuel Level I/O parameters
2021.10.15  - B.3.27_R.25       - LR    - FMBP-14121 -  Release:
                                - MA    - FMBP-14200 -  [ADD] FMB920 support for Traxgo Spec
                                - JZ    - FMBP-14233 -  [REM] Preferred Operator selection
                                - LR    -            -  [UPD] Configurator Source to 1.7.30
                                - JZ    - FMBP-14141 -  [FIX] Jamming feature for BG95 devices
2021.09.17  - B.3.27_R.24       - LR    - FMBP-12886 -  Release:
                                - LR    - FMBP-13810 -  [MRG] 03.27.05.Rev.52 to base
                                - JŽ    - FMBP-13110 -  [UPD] FotaWeb check period max to 12h
2021.08.03  - B.3.27_R.23       - MA    - FMBP-12879 -  Release:
                                - MA    -            -  [UPD] Configurator source to 1.7.26 and to newest localization.
                                - ArS   - FMBP-11759 -  [FIX] Moved BLE feature check
                                - JB    - CONF-148   -  [ADD] Added Gree/eco driving calculation
                                - ArS   - FMBP-9143  -  [FIX] Moved RS232 description ending
2021.07.28  - B.3.27_R.22       - MA    - FMBP-12785 -  Release:
                                - MA    -            -  [UPD] Configurator source to 1.7.25 and to newest localization.
                                - JŽ    - FMBP-12498 -  [FIX] Input symbol validation for sms number
2021.06.28  - B.3.27_R.21       - MR    - FMBP-12192 -  Release:
                                - ArS   - FMBP-9143  -  [UPD] cfg source to 1.7.22
                                - ArS   - FMBP-9143  -  [FIX] RS232 help window
2021.06.11  - B.3.27_R.20       - MR    - FMBP-11892 -  Release:
                                - JŽ    -            -  [UPD] Configurator Source to 1.7.21
                                - JŽ    - FMBP-11761 -  [FIX] Default towing duration value
                                - JŽ    - FMBP-11650 -  [ADD] Beacon record priority selection
                                - JB    - FMBP-11621 -  [FIX] fixed spec 105 dublicated authorization ids
2021.05.28  - B.3.27_R.19       - LR    - FMBP-11561 -  Release:
                                - LR    -            -  [UPD] Configurator Source to 1.7.20
                                - JŽ    - FMBP-11026 -  [ADD] Data Acquisition tooltips
                                - JŽ    - FMBP-11302 -  [FIX] Advanced eco driving mode visibility
                                - AlS   - FMBP-9143  -  [FIX] rs232 mode tooltips fixed
                                - AlS   - FMBP-11237 -  [ADD] Added missing tooltips
                                - JŽ    - FMBP-5530  -  [REM] Removed crash counter from 03.25 base
                                - AlS   - FMBP-8476  -  [FIX] Geozone radius, frame border units added
                                - AlS   - FMBP-7204  -  [FIX] Event only tooltip fixed
                                - AlS   - FMBP-9773  -  [FIX] Specid107 default config values fixed
2021.05.17  - B.3.27_R.18       - MR    - FMBP-11190 -  Release:
                                - JŽ    - FMBP-10782 -  [FIX] Fixed BLE parameter label
                                - JŽ    - FMBP-9647  -  [FIX] Small tooltip fixes
                                - JB    - FMBP-11067 -  [ADD] added support for fmb140,130 spec 105
                                - JB    - CONF-487   -  [FIX] Fixed packet merge, binary prefix and garmin mode visibility
                                - JB    - FMBP-9732  -  [FIX] fixed delimeter keyword visibility in spec 107 on rs232 delimeter mode
                                - AlS   - FMBP-9145  -  [REM] rs232 parameters duplicate removed
                                - JŽ    - FMBP-10799 -  [FIX] Missing 1-Wire mode selection
                                - AlS   - FMBP-11050 -  [ADD] Added ble aes128 encryption
                                - ZG    - FMBP-10655 -  [UPD] Configurator-source updated to 1.7.16
                                - AlS   - FMBP-1070  -  [REM] Spec id 107 support removed from FMT100, spec id 102 from FMB0
2021.04.30 - B.3.27_R.17        - LR    - FMBP-10899 -  Release:
                                - LR    - FMBP-10831 -  [MRG] Base 03.25.18.Rev.07
                                - JB    - FMBP-10582 -  [ADD] added fmb140 support of spec 107
                                - AS    - FMBP-9143  -  [ADD] Added RS232/RS485 parameters configuration values description.
                                - AS    - FMBP-2261  -  [FIX] DOUT1 avg const default value changed to 1
                                - LR    - FMBP-3582  -  [FIX] Replace Eventual beacon record with On Change
2021.04.19 - B.3.27_R.16        - MR    - FMBP-10346 -  Release:
                                - ZG    - FMBP-9773  -  [FIX] DINx minutes IO param default values fixed
                                - LR    - FMBP-6367  -  [FIX] Universal Beacon parameter Tooltips
                                - LR    - FMBP-1057  -  [FIX] Inverted DOUT Label and Description
---------------------------------------------------------------------------------
2021.04.06 - B.3.27_R.15        - JB    - FMBP-9612 -  [FIX] fixed dublicated pulse io parameters din 1 and 2
                                - OK    - FMBP-9725 -  [FIX] Missing DOUT3 & DIN3 for spec 116 business trip control
                                - FY    - FMBP-7303 -  [FIX] Spaces between parameter name and its unit
                                - MR    - FMBP-3203 -  [FIX] 154 Spec advanced ecodrv is configurable
2021.03.19 - B.3.27_R.14        - MR    - FMBP-9738 -  Release:
                                - MR    - FMBP-2523 -  [ADD] Universal beacon support
                                - LR    - FMBP-790  -  [MRG] 03.26.00.Rev.51 FW (inverted DOUT functionality)
                                - RSu   - FMBP-7613 -  [ADD] Added missing parameters that the fw already had
2021.02.19 - B.3.27_R.13        - MR    - FMBP-8834 - Release:
                                - MR    -           -  [FIX] Traxgo FMB130 missing parameters
                                - MR    - FMBP-9167 -  [MRG] B.3.25_R.5 base configurator
                                - MR    - FMBP-7375 -  [ADD] Beacon on change functionality
                                - MR    - FMBP-3268 -  [FIX] BLE Fuel Freq High level not configurable
                                - MR    - FMBP-7207 -  [FIX] Missing DIN2 On Demand Tracking source
                                - MR    - FMBP-8799 -  [FIX] Duplicate Ground sens IO
                                - MR    - FMBP-8828 -  [FIX] Spelling mistake in crash event tooltip
                                - MR    - FMBP-1019 -  [FIX] Odometer tooltips for FMC/U/M devices
                                - ZG    - FMBP-1028 -  [FIX] fixed missing tooltips
                                - VBe   - FMBP-8325 -  [ADD] Immo auth tmo to base
                                - LR    - FMBP-8365 -  [ADD] Traxgo Delimiter Keyword, Lockdown and TripStart parameters
2021.01.14 - B.3.27_R.12        - MA    - FMBP-8565 -  Release:
                                - US    - FMBP-7156 -  [FIX] Fix default Eskort LLS, GndSens & LVCAN SMS strings and default parameter values
2021.01.07 - B.3.27_R.11        - MA    - FMBP-7942 -  Release:
                                - MR    - FMBP-8387 -  [MRG] 03.25.18.Rev.03 changes
                                - ASe   - FMBP-7581 -  [ADD] Beacon tooltip note
2020.11.19 - B.3.27_R.10        - MR    - FMBP-7060 -  Release:
                                - LR    - FMBP-6798 -  [ADD] FMB910 HW Support
2020.10.19 - B.3.27_R.9         - MA    - FMBP-6438 -  Release:
                                - MA    - FMBP-2597 -  [FIX] Removed CAN-CONTROL from immobilizer.
                                - OK    - FMBP-6672 -  [ADD] Missing pulse counter to FMB130. Added from version 6.1.14.0
                                - OK    - FMBP-6402 -  [ADD] Missing available operator output control for FMB2YX. Added to version from 8.6.0.0
                                - AV    - FMBP-5997 -  [FIX] Minew S1 BLE sensor presets
2020.09.30 - B.3.27_R.8         - MR    - FMBP-6179 -  Release:
                                - MR    - FMBP-6279 -  [ADD] Configuration from 03.25.15.Rev.32 FW
                                - MR    - FMBP-2217 -  [FIX] Duplicate RS232 parameters
                                - MR    - FMBP-5829 -  [MRG] Merge E.fmb14x_dev_R.1
                                - IN    - FMBP-2597 -  [FIX] Immobilizer output control FMC130
2020.09.03 - B.3.27_R.7         - MR    - FMBP-5579 -  Release
                                - MR    - FMBP-5546 -  [ADD] New UMTS/LTE Cell Id IO
                                - MR    - FMBP-5544 -  [UPD] Configurator sources to 1.7.4
2020.08.20  - B.3.27_R.6        - MR    - FMBP-5285 -  Release
                                - JF    - FMBP-3794 -  [FIX] LVCAN Unit multipliers
                                - KrBa  - FMBP-243  -  [UPD] Pulse Counter High level max values
                                - OK    - FMBP-4760 -  [FIX] Missing/extra parameters
2020.07.27  - B.3.27_R.5        - SP    - FMBP-4892 -  Release
                                - EC    - FMBP-4726 -  [ADD] TzBt Data clear period
                                - EC    - FMBP-4760 -  [ADD] Configurations from 03.25.xx branch
                                - VBe   - FMBP-4141 -  [FIX] BLE scan param visibility (again again)
2020.07.07  - B.3.27_R.4        - SP    - FMBP-4309 -  Release
                                - AV    - FMBP-4311 -  [FIX] 03.25.16.Rev.04 base merge into 03.27.xx missing configuration/localization
                                - JF    - FMBP-4434 -  [FIX] Spec configurations to seperate files
                                - VBe   - FMBP-4141 -  [FIX] BLE scan param visibility (again)
                                - EV    - FMBP-528  -  [FIX] Increased max movement delay value
                                - VBe   - FMBP-4141 -  [FIX] BLE scan param visibility
                                - AV    - FMBP-4221 -  [FIX] Missing Data Acquisition Change parameter in Towing Detection scenario
2020.06.09  - B.3.27_R.3        - SP    - FMBP-3533 -  Release
                                - JF    - FMBP-4022 -  [MRG] E.fmb140_lvcan_R.50 into release/03.27.00.Rev.XX
                                - JF    - FMBP-4022 -  [MRG] E.fmb140_lvcan_R.1 into release/03.27.00.Rev.XX
                                - MA    - FMBP-4024 -  [UPD] FMU configurator branch
                                - JF    - FMBP-3257 -  [FIX] Fake towing default values
                                - VBe   - FMBP-3273 -  [FIX] Ground sense visibility
                                - VBe   - FMBP-3316 -  [FIX] BLE fuel level duplicate
                                - VBe   - FMBP-2896 -  [FIX] duplicate parameters
2020.04.20  - B.3.27_R.2        - GS    - FMBP-3036 -  Release
                                - KB    - FMBP-2154 -  [ADD] 4000 iButton list as base feature
                                - VBe   - FMBP-2896 -  [FIX] FMB140 duplicate params
2020.04.03  - B.3.27_R.1        - GS    - FMBP-2440 -  Release
                                - GS    -           -  [MRG] master (update configurator-source and debug_configurator.exe)
                                - VBe   - FMBP-2534 -  [FIX] crash counter
                                - GS    - FMBP-2597 -  [FIX] immobilizer output control
                                - GS    -           -  [FIX] lvcan io missing control
                                - VBe   - FMBP-1469 -  [FIX] Missing Instant movement IO
                                - EV    - FMBP-2015 -  [FIX] commander tmo min value
                                - VBe   - FMBP-2217 -  [FIX] Duplicate RS232 parameters
                                - GS    - FMBP-2020 -  [ADD] Missing FMB130/140 controls
                                - VBe   - FMBP-927  -  [FIX] Missing DOUT control tooltip
                                - GS    - FMBP-2326 -  [MRG] 03.27.xx release into master
                                - VBe   - FMBP-1481 -  [FIX] RS232 double parameters
                                - VBe   - FMBP-2024 -  [FIX] Movement source select
                                - US    - FMBP-496  -  [ADD] Add AutoAPN setting and APN file transfer
                                - PB    - FMBP-2077 -  [ADD] new LVC Module ID 17B IO
---------------------------------------------------------------------------------
2021.04.28  - B.3.25_R.8       - Kibo  - FMBP-10854 - Release:
                               - AJ    - FMBP-9033 -  [REV] Configurator base
                               - KiBo  - FMBP-10652-  Removed unsupported LVCAN IOs
2021.02.24  - B.3.25_R.7       - ZG    - FMBP-9033 -  Release:
                               - ZG    - FMBP-9033 -  [FIX] Configurator button pressed on APN file upload
                               - RSu   - FMBP-7613 -  [ADD] Added missing parameters that the fw already had
2021.01.19  -                  - JB    - FMBP-9086 -  [FIX] Default towing values
2021.02.18  - B.3.25_R.6       - KrBa  - FMBP-8855 -  Release:
                               - KrBa  - FMBP-9002 -  [FIX] Towing hardwares and default values
2021.01.xx  - B.3.25_R.5       - AJ    - FMBP-8275 -  Release:
                               - KrBa  - FMBP-4633 -  [FIX] Default towing values
                               - VBe   - FMBP-7429 -  [FIX] Crash counter visibility
2020.10.23  - B.3.25_R.4       - LR    - FMBP-6822 -  Release:
                               - TB    -   29670   -  [ADD] APN file transfer localization info
                               - TB    -   29676   -  [ADD] Transfer APN file
                               - US    -   26794   -  [ADD] AutoAPN search functionality [Enable/Disable] (FMB0/1/9, FM3/4, FMT1, MTB1, TMT25, exc. storageless)
                               - LR    - FMBP-6798 -  [ADD] FMB910 HW Support
2020.07.03  - B.3.25_R.3       - PK    - FMBP-4197 -  Release:
                               - PK    - FMBP-4197 -  [FIX] Duplicate RS232 baudrate
2020.06.09  - B.3.25_R.2       - LR    - FMBP-4066 -  Release:
                               - LR    - FMBP-4003 -  [ADD] Spec ID 154 DigiCore Technology
                               - LR    - FMBP-4003 -  [ADD] Eco Driving Hold-Off parameter for spec 154
---------------------------------------------------------------------------------
OLD versioning
---------------------------------------------------------------------------------
DATE:       - VER:      - C:    - A:    - JIRA:     - CHANGES:
---------------------------------------------------------------------------------
2020.03.13  - 1.5.16    - 001   - US    - FMBP-1962 -  Release
                                - US    - FMBP-496  -  [ADD] Add AutoAPN setting and APN file transfer
                                - PB    - FMBP-2077 -  [ADD] new LVC Module ID 17B IO
                                - VBe   - FMBP-1481 -  [FIX] RS232 double parameters
                                - VBe   - FMBP-2024 -  [FIX] Movement source select
                                - AJ    - FMBP-2078 -  [ADD] FMU/FMC/FMM/MCX support & horometer scenario
---------------------------------------------------------------------------------
2020.02.24  - 1.5.5     - 003   - EV    - FMBP-1960 -  Release (Updated gitlab url)
2020.02.24  - 1.5.5     - 002   - EV    - FMBP-1960 -  Release
                                - VBe   - FMBP-952  -  [REM] LVCAN ID17
                                - VBe   - FMBP-952  -  [FIX] BT4 help text and tooltip
                                - VBe   - FMBP-953  -  [REM] User ID IO tooltip
                                - VBe   - FMBP-1043 -  [FIX] HW specific tooltips
                                - VBe   - FMBP-928  -  [FIX] Help text
                                - VBe   - FMBP-929  -  [FIX] Crash tooltips
---------------------------------------------------------------------------------
2020.01.30  - 1.5.5     - 001   - GS    - FMBP-502  -  Release
                                - MR    - FMBP-1058 -  [FIX] Ecodriving parameters
                                - VBe   -   26080   -  [FIX] UL202 implementation
                                - VBe   -   30488   -  [FIX] Pulse counter tooltips (spec 107)
                                - VBe   -   27446   -  [FIX] Base parameter tooptips and help text
                                - VBe   -   27448   -  [FIX] Crash detection tooltip
                                - VBe   -   30533   -  [FIX] Missing Frame border units
                                - VBe   -   26817   -  [FIX] MTB100 missing crash parameters
                                - VBe   -   30508   -  [ADD] Pulse Counter info
                                - GS    -           -  [MRG] Merge remote-tracking branch 'exp/FMB14x' into master
                                - JF    -   29991   -  [ADD] Autoscan funcionality
                                - GS    -           -  [MRG] Merge remote-tracking branch 'origin/release/3.25.14.Rev.xx' into master
                                - VP    -           -  [ADD] FM64 Battery charging mode.
                                - VP    -   29369   -  [ADD] FM64 Carrier Setpoint2. Zone 1/2 supply and return temperatures.
                                - DK    -   29437   -  [ADD] FM64 Spec.1022 Configurable parameters update.
                                - DK    -  FM64-83  -  [ADD] Datu spec 1023, CAN data reading from train at 25kbits
                                - VP    -  FM64-302  - [ADD] DOUT Control to every geozone.
---------------------------------------------------------------------------------
2019.12.19  - 1.4.10    - 104   - MA    -           -  [FIX] Advanced eco drving configuration fix.
2019.12.17  -           -       - IN    -   30278   -  [FIX] GNSS source (made a mistake earlier)
2019.12.17  -           -       - IN    -   30278   -  [FIX] GNSS source
2019.12.10  -           -       - IN    -   30289   -  [FIX] Static navigation tooltip
2019.12.10  - 1.4.10    - 103   - IN    -   30008   -  [FIX] Online/offline default config differences
                                - VBe   -   20103   -  [FIX] GNSS Fuel Correction Coefficient
                                - VR    -   29876   -  [ADD] FM64 iButton Notification List check parameters.
                                - VP    -   30155   -  [FIX] FM64 Movement stop delay max value from 300 to 65536.
                                - VP    -   30159   -  [ADD] FM64 Spec.1016 RS232 TCP Commands.
                                - IN    -   30278   -  [FIX] GNSS source (made a mistake earlier)
                                - IN    -   30278   -  [FIX] GNSS source
                                - VR    -   29876   -  [ADD] List check and depend on ignition for iButton notification
                                - GS    -           -  [MRG] Merge remote-tracking branch 'origin/release/3.25.14.Rev.xx' into master
2019.12.06  - 1.4.10    - 102   - MR    -   30318   -  Release:
                                - MR    -   30299   -  [ADD] New UL202 status IO
                                - LR    -   30267   -  [ADD] Add Spec ID 148 for Quartix
                                - GS    -   29647   -  [FIX] Add missing control options for dout/din
                                - EV    -   19162   -  [FIX] Fixed several tooltips
                                - MR    -   29211   -  [ADD] 5 Custom BLE Advanced sensors IO
                                - EV    -   28755   -  [UPD] Updated ign source tooltip
                                - DK    -   27495   -  [FIX] MCX localization and fm64 base tooltips and labels.
                                - DK    -   30000   -  [FIX] FMM640 com modes visibility differ fix.
                                - VP    -   30158   -  [ADD] FM64 Spec.1017 missing tooltips.
                                - VP    -   30084   -  [ADD] FM64 Spec.1021 missing tooltips.
                                - KrBa  -   26477   -  [FIX] Average constant removed for Pulse Counter DINs
                                - KrBa  -   29277   -  [FIX] DIN2/AIN1 and ground sense input
                                - KrBa  -   26049   -  [ADD] Added din4 and ain2 in sms text description
                                - KrBa  -   25896   -  [ADD] Added ground sense and dout3 in sms text description
                                - EV    -   28755   -  [UPD] Updated ignition source f1 tooltip.
                                - DK    -   29437   -  [ADD] FM64 Spec.1022 (BaseqEngineering) Configuration.
                                - GS    -           -  [MRG] Merge remote-tracking branch 'origin/release/3.25.14.Rev.xx' into master
2019.10.31  - 1.4.10    - 001   - GM    -   29701   -  Fix Multiple stateSwitch controls with same parameter Id, property -> collection validation
2019.10.30  - 1.4.9     - 001   - VP    -   29712   -  [ADD] FM64 Operand for MCAN I/O elements.
2019.10.29  - 1.4.9     - 001   - GM    -   29712   -  Add Offset attribute to Operand control
2019.10.24  - 1.4.8     - 001   - GM    -   29345   -  Main release case
                                - GS    -           -  [MRG] Merge remote-tracking branch 'origin/release/3.25.10.Rev.xx' into feature/merge_03.25.14_to_develop
2019.10.24  - 1.4.5     - 004   - KM    -   29302   -  [ADD] FM64 LVCAN DTC request added
					    	    - EV    -   25339   -  [FIX] EGTS configuration fix (do not show UDP)
								- IB	-   27965   -  [ADD] FM64 Spec.1021 (QEOS) Configuration.
2019.10.11  - 1.4.5     - 003   - VP    -   29539   -  [ADD] FM64 Spec.1019 Configuration ID Change.
2019.10.11  - 1.4.5     - 003   - VP    -   29499   -  [ADD] FM64 Spec.1020 Missing tooltips.
                                - GS    -   25304   -  [FIX] Battery Voltage IO for HW with Nihm battery
                                - GS    -   22886   -  [FIX] Move odometer control box from advanced trip settings
                                - GS    -   27548   -  [FIX] Move crash counter from base to spec 132 for fmt100
2019.10.11  - 1.4.5     - 002   - VP    -   29162   -  [ADD] FM64 FMB64 Hardware. Beidou and Galileo configuraton
2019.10.11  - 1.4.5     - 002   - GS    -   29162   -  [ADD] FM64 Spec.1019 (RoadTech) Configuration.
2019.10.11  - 1.4.5     - 002   - VP    -   29234   -  [ADD] FM64 Spec.1020 (KIP) Configuration.
                                - EV    -   28668   -  [ADD] Added missing Codec12/13 merge parameter
                                - EV    -   28651   -  [FIX] Advanced eco driving parameter now depends on movement source
                                - GS    -   29306   -  [FIX] Wrong dallas control for commander
                                - GS    -   29306   -  [FIX] Wrong dallas control for commander
2019.10.15  - 1.4.5     - 051   - GS    -   29492   -  [FIX] missing mtb variation for inverted dout control
2019.10.14  - 1.4.5     - 050   - GS    -   29389   -  Exp release - Inverted DOUT1 option
2019.10.07  - 1.4.5     - 001   - GM    -   28831   -  Main release case
2019.10.02  - 1.4.1     - 003   - US    -   28615   -  [FIX] Fix duplicate "Instant movement" IO
2019.09.24  - 1.4.1     - 002   - KM    -           -  [FIX] Correct old version added for 4.28++ configuration
2019.09.20  - 1.4.1     - 001   - GM    -   28831   -  Main release case
2019.09.20  - 1.4.0     - 001   - GM    -   28831   -  Main release case
2019.09.17  -           -       - DK    -   27495   -  [FIX] MCX localization
2019.09.10  -           -       - OK    -   28504   -  [ADD] Spec.1002 set wake up by movement availability.
2019.09.04  - 1.3.23    - 002   - DK    -   28497   -  [ADD] new hw FMM640
2019.09.02  - 1.3.23    - 001   - GM    -   28450   -  Main release case
2019.08.30  - 1.3.19    - 010   - VP    -   28768   -  [REM] FM64 SBD upload limit parameter.
2019.08.30  - 1.3.19    - 009   - VP    -   28768   -  [ADD] FM64 SBD upload limit parameter.
2019.08.28  - 1.3.19    - 009   - VP    -   28702   -  [REM] FM64 Spec.1018 Server domain configuration.
2019.08.27  - 1.3.19    - 008   - VP    -   28534   -  [FIX] FM64 "Carrier Freezer" -> "Carrier Reefer"
2019.08.27  - 1.3.19    - 008   - VP    -   28096   -  [REM] FM64 Averaging constant for fuel counter.
2019.08.20  - 1.3.19    - 007   - PK    -   28272   -  [ADD] Ported Arobs spec parameters from FMB.
2019.08.20  - 1.3.19    - 006   - VP    -   28393   -  [REM] FM64 iButton notification off tmo parameter.
2019.08.12  - 1.3.19    - 005   - AJ    -           -  Added all parameters from 3.22.0.0 -> 5.0.3.0 versions
													-  TMT250 specific parameters added
													-  Added efento sensor BLE configuration
													-  Added EGTS backup server selection
													-  Added AROBS spec parameters
													-  Updated AROBS spec parameters from "arobs_scen"
													-  Added towing scenario DOUT control ON & OFF duration configuration
													-  Removed timesync mode selector (timesync_imp)
													-  Added TomTom (124) spec to base
													-  Added Movolytics (126) spec to base
													-  Added TLS (encryption parameters) + tooltips
2019.08.12  -           -       - KM    -   27735   -  [FIX] Fixed spec: 1014 parameter 99625. Min value set to 1000 as in fw.
2019.08.09  -           -       - DK    -   24727   -  [FIX] Fixed spec: 107 rs232/485 collections
2019.08.07  -           -       - JF    -   27548   -  [FIX] Removed crash counter from base
2019.08.07  -           -       - DK    -   27877   -  [FIX] Change Freezer IO parameters names
2019.08.05  -           -       - DK    -   28254   -  [FIX] DIN/DOUT visibility dependencies
2019.08.05  - 1.3.19    - 004   - AJ    -   28098   -  [FIX] SMS prefix displaying only with 139 spec id configurations
2019.08.02  - 1.3.19    - 003   - VP    -           -  [REM] FM64 Passenger iButton control from base.
2019.08.01  - 1.3.19    - 002   -DaAl   -   27851   -  [FIX] 135 special firmware parameters
2019.08.01  -           -       - DK    -   24727   -  [FIX] Fix 107spec configuration
2019.08.01  -           -       - AV    -   27739   -  [ADD] Missing instant movement IO
2019.08.01  -           -       - JF    -   27850   -  [ADD] CMD ID for RS232/RS485 TCP.
2019.08.01  - 1.3.19    - 001   - GM    -   28436   -  Add OpenStreeMaps copyrights
2019.07.31  - 1.3.18    - 003   - VP    -   27948   -  [FIX] FM64. Freezer IO elements naming.
2019.07.31  - 1.3.18    - 002   - VP    -   28413   -  [CHANGE] FM64. Freezer request period default values.
2019.07.31  - 1.3.18    - 001   - GM    -   28363   -  Main release case
										-   27785   -  Fix Rs232/Rs485 packet display
										-   28183   -  Fix Settings issues, when loading settings after entering spec key [28304,27146]
										-   28364   -  Add IRNSS parameters (0x117, 0x118)
										-   28189   -  Fix error label font colour
										-   27548   -  Remove Crash counter from base
2019.07.30  - 1.3.15    - 008   - VP    -   27610   -  Fix FM64. IO naming TPMS->ContiPressureCheck.
2019.07.30  - 1.3.15    -       -DaAl   -   27851   -  Fix 135spec configuration
2019.07.29  - 1.3.15    -       - DK    -   24727   -  Fix 119spec configuration
2019.07.29  - 1.3.15    -       - DK    -   24727   -  Fix 116spec configuration
2019.07.26  - 1.3.15    -       - DK    -   24727   -  Fix 114spec configuration
2019.07.26  - 1.3.15    -       - DK    -   24727   -  Fix 110spec configuration
2019.07.25  - 1.3.15    - 007   - JF    -   28218   -  Added Tire temperature and warning configuration
2019.07.23  - 1.3.15    -       - DK    -   24727   -  Fix 104spec configuration
2019.07.22  - 1.3.15    -       -DaAl   -   27548   -  Fix crash counter parameter
2019.07.19  - 1.3.15    - 006   -DaAl   -   28161   -  Add parameter for FMT eco driving selection
2019.07.18  - 1.3.15    -       - VP    -   28104   -  Change: FM64 "Authentification Timeout"  changes for spec 1016 reverted
2019.07.18  - 1.3.15    - 005   - VP    -   27876   -  Fix: FM64 par_id = 99720 tooltip fixed.
2019.07.17  - 1.3.15    - 004   - MA    -   28196   -  Changed BT local name configuration.
2019.07.16  - 1.3.15    - 003   - VP    -   27959   -  Add: FM64 Spec.1017 Thermoking parameters.
2019.07.16  - 1.3.15    - 002   - GS    -   28098   -  Add 139 spec and move sms prefix under spec
2019.07.16  - 1.3.15    - 002   - GS    -   27459   -  Add bt security mode for fmb64 (pin code and pairing mode)
2019.07.11  - 1.3.15    - 001   - GM    -   TBA     -  Add Visibility/Invisibility dependencies to IO elements
2019.07.09  - 1.3.14    - 005   - VP    -   27437   -  Change: FM64 IO data not present logic rework.
2019.07.09  - 1.3.14    - 004   - VP    -   27437   -  Change: FM64 IO data not present logic rework.
2019.07.09  - 1.3.14    - 003   - VP    -           -  Fix: FM64 status window.
2019.07.09  - 1.3.14    -       - GS    -   27437   -  Add IO Data Send Mode as global parameter
2019.07.08  - 1.3.14    - 002   - MA    -   27975   -  Added Same config ID IO localization for diferent hws
2019.07.05  - 1.3.14    - 001   - GM    -   28033   -  Add Visibility/Invisibility dependencies to ControlType="Group"
2019.07.04  - 1.3.13    - 001   - GM    -   25090   -  Add proper info message after transmitting firmware when device works from battery only
										-   27799   -  Add 10 chars trim on entering keyword
										-   27885   -  Fix default collections localization
										-   27785   -  Wrap RS232/RS485 packet display on UI
										-   27798   -  Increase download file from path timeout from 60s to 240s
2019.07.02  - 1.3.10    - 009   - VP    -   27873   -  Change: FM64 Spec.1015 Camera mode -> show msg timestamp config.
2019.07.02  - 1.3.10    - 008   - VP    -   27610   -  Change: FM64 TPMS->Continental Pressure Check.
2019.07.02  - 1.3.10    - 007   - VP    -   27948   -  Fix: FMS and Fridge grammar errors.
2019.06.28  - 1.3.10    - 006   - VP    -   23158   -  Add: FM64 movement source configuration.
2019.06.28  - 1.3.10    - 005   - PK    -   26431   -  IoTag spec 1016 parameters added
2019.06.27  - 1.3.10    - 005   - PK    -   27547   -  T-One default values fixed
										-   27537   -  T-One Crash detection parameter fixed
2019.06.25  - 1.3.10    - 004   - GS    -   27483   -  Add sms prefix
2019.06.13  - 1.3.10    - 002   - DK    -   27592   -  Spec ID 138 added
2019.06.12  - 1.3.10    - 001   - GM    -   27594   -  Add VisibilityDependencies to <ViewConfiguration/> element
								- GM    -   27576   -  Fix Dynamic Table display
2019.06.11  - 1.3.9     - 004   - PK    -   26431   -  IOtag parameters removed from FMB64 base
2019.06.10  - 1.3.9     - 003   - AJ    -   27028   -  Changed crash trace default value to disabled
2019.06.07  - 1.3.9     - 002   - MA    -   27478   -  Added new base IO element - Coordinates
                                - SP    -   27332   -  Added Vehicles Range On Battery/Additional Fuel
                                -DaAl   -   26484   -  Update FMT100 eco driving parameters
2019.06.06  - 1.3.9     - 001   - LV    -   22196   -  Remove logging "Completed" from BluetoothDeviceMonitor
2019.06.06  - 1.3.8     - 003   - AJ    -   27434   -  Changed FMB64 configuration titles to be more generic for branding
2019.06.05  - 1.3.8     - 002   - VP    -   27410   -  Change: FM64 Spec.1010 Correctly name 51000 and 51010 Elements.
2019.06.05  - 1.3.8     - 001   - LV    -   16635   -  Update Read Records Bluetooth Timeout
2019.06.05  - 1.3.7     - 004   - VP    -   27404   -  Add: FM64 Missing tooltips for 51-100 geozones.
2019.06.05  - 1.3.7     - 003   - VP    -   27522   -  Add: FM64 Dout control via Call. Allow duration configuration only if no Din trigger is selected.
2019.06.05  - 1.3.7     - 002   - VP    -   22914   -  FM64. Added Polygon Geozones support 10 points
2019.06.04  - 1.3.7     - 001   - LV    -   16635   -  Change Read Records Timeout 10sec -> 30sec
2019.05.28  - 1.3.6     - 001   - GM    -   24028   -  Add error message when dump count is 0
										-   None    -  Fix null reference exception while receiving Statuses
2019.05.24  - 1.3.5     - 005   - PK    -   26431   -  Added IO element Passenger iButton
2019.05.23  - 1.3.5     - 004   - AJ    -   27003   -  Changed BT status default operand value from 5 to 3
2019.05.23  - 1.3.5     - 004   - AJ    -   26993   -  Add missing green driving duration when GPS source is selected
2019.05.23  - 1.3.5     - 003   - PK    -   26431   -  Added Idling speed start/stop thresholds, buzzer duration, passenger iButton source parameters.
2019.05.22  - 1.3.5     - 002   - AJ    -   27113   -  T-One SPEC merged to base.
								- AJ    -   26339   -  Combine 131 and 134 spec id's into 137 -> for Integrated Solutions
								- AJ    -   25106   -  Added DOUT control via ignition functionality.
							    - AJ    -   24250   -  Merge KvadratMAP (towing functionality) to base
2019.05.20  - 1.3.5     - 001   - GM    -   27180   -  Main release case
										-   24036   -  Fix crash after FW update when using BT port
										-   25684   -  Fix connected devices display after FW update
										-   25546   -  Fix connected devices display when there are more than one device connected after FW update
										-   20974   -  Fix set/remove keyword commands using BT port
										-   26045   -  Fix ports stability
										-	19460	-  Fix BT connection
										-	25349	-  Add reconnect after FW update
										-	16635	-  Change Read Records Timeout 10sec -> 30sec
										-	24751	-  Fix Fw update crash
										-	26486	-  Fix I/O Statuses data size changes
										- 	27221	-  Add Adapter Name[0x313] and Adapter Id[0x314] parameters to Can status
										-   27220   -  Fix Configurator crash while ALL-Can is connected
										-	26292   -  Fix Configurator crash while receiving data in status window
										-   21687   -  Fix Can statuses display
										-	27167	-  Fix Reboot command for devices with keyword set
										-   None    -  Fix generated views layout
										-   None    -  Refactor Status mapping, Format Micro Sd command
2019.05.16  - 1.3.2     - 005   - AV    -   27028   -  Change defaults for Eco/Green driving and axl crash to be like on T-One
2019.05.16  - 1.3.2     - 004   - AV    -   27104   -  FMB Spec.119 missing iButton list on some HW fixed.
2019.05.16  - 1.3.2     - 003   - VP    -   27006   -  FM64 Spec.1002 IoSz collection fixed.
2019.05.09  - 1.3.2     - 002   - VP    -   26346   -  FM64 Spec.1015 add restriction: Record SavePeriod cant't be bigger then SendPeriod.
2019.05.09  - 1.3.2     - 001   - GM    -   27184   -  Fix assigned image to List visibility
2019.05.08  - 1.3.1     - 002   - GM    -   None    -  Add forgotten during build Teltonika.MapControl.dll
2019.05.08  - 1.3.1     - 001   - GM    -   25256   -  Change Store Configuration serial port timeouts for FM6400, FMB640, FMC640 from 10s to 20s
2019.05.07  - 1.3.0     - 001   - GM    -   26928   -  Main release case
										-   19229   -  Fix Configurator crash while double clicking .cfg file
										-   26139   -  Add Reset Configuration command animation
										-   21687   -  Add Obd/LvCan presence parameters
										-   19229   -  Change "Create new configuration", "Open configuration file" appearance on home view
										-   None    -  Add IBeacon/Eddystone/Manual geofence/Search logos
2019.05.07  - 1.2.13    - 005   - VP    -   27032   -  FM64 RS232 added separator.
2019.04.29  - 1.2.13    - 003   - VP    -   27035   -  FM64 RS485 Log mode removed.
2019.04.25  - 1.2.13    - 002   - VP    -   None    -  FM64 Spelling of Eco Driving source values fixed.
2019.04.18  - 1.2.13    - 001   - GM    -   26847   -  Fix invalid values are set bug
										-   24431   -  Fix DIN triggers configuration
										-	26893	-  Fix Accelerometer data read
										-	26905	-  Fix SW crash when pressing spec key back button
2019.04.17  - 1.2.10    - 001   - AV    -   26830   -  DOUT Max duration in overspeeding changed
2019.04.15  - 1.2.10    - 001   - LV    -   23373   -  Add Priority Switch Control
2019.04.12  - 1.2.9     - 002   - AJ    -   25883   -  Add DOUT 3 control for scenarios with FMB130 device
2019.04.12  - 1.2.9     - 002   - AJ    -   24561   -  Add Battery charging mode "Always"
2019.04.11  - 1.2.9     - 001   - GM    -   26502   -  Allias implementation into Hardware.xml
										-	26802	-  Remove objectToDecimalConverter because it was not neccessary for StatusDataResponse
										-   None    -  Update BuildBrand.exe to 2.0 version
										- 	None 	-  Change Brand submodule relative path
2019.04.10  - 1.2.8     - 004   - VP    -   26525   -  FMB64 Spec.1006 Status Window Fix.
2019.04.10  - 1.2.8     - 003   - VP    -   26747   -  FMB64 COM1 Modes confict with FMB resolved.
2019.04.08  - 1.2.8     - 002   - VP    -   26500   -  Carrier IO element zone temperature added.
2019.04.08  - 1.2.8     - 001   - GM    -   26209   -  Change 0x228 from uint16 to uint32
										-	None	-  Fix configurator crash while pressing back button in spec key window
2019.04.05  - 1.2.7     - 001   - AV    -   25953   -  Sattelite -> Satellite fix
2019.04.04  - 1.2.7     - 001   - GM    -   None   	-  Fix Ctrl+Shift+Alt selected configuration generation
										-	None	-  Fix Status data response value logging
2019.04.03  - 1.2.6     - 002   - VP    -   25820   -  Added Spec.Id 135 (Thinxnet Configuration)
2019.04.03  - 1.2.6     - 001   - GM    -   23641   -  Change display of sockets
										-	26458	-  Update FMB900/FMB920 device logos
										-	None	-  Add socket2, socket3 usage types localization
2019.04.03  - 1.2.5     - 002   - TM    -   26195   -  specs<1001,1002,1009,1010,1011,1012> 4.19 fixed COM1/COM2 no more doubling modes
2019.04.02  - 1.2.5     - 001   - GM    -   24823   -  Add Beacons statuses display in Status window
										-   26442   -  Add Read records / Firmware update styles configuration to BrandResourceDictionary.xaml
										-   None    -  Add Beacons status tab localization
2019.04.01  - 1.2.4     - 003   - AJ    -   26376   -  Merge mapit spec to base
2019.04.01  - 1.2.4     - 003   - AJ    -   25980   -  Add pulse counter functionality
2019.04.01  - 1.2.4     - 003   - AJ    -   23570   -  Changed max odometer value, trip odometer value and type
2019.03.29  - 1.2.4     - 002   - VP    -   26362   -  Spec.1015. Matrix Dout Default value change to DOUT1.
2019.03.28  - 1.2.4     - 001   - LV    -   26362   -  Fix missing Settings button, add open-cfg localization
2019.03.28  - 1.2.3     - 003   - VP    -   26351   -  FMB64 IO Localization fix.
2019.03.27  - 1.2.3     - 002   - KM    -   25642   -  FM64 Matrix (1015) spec id added
2019.03.27  - 1.2.3     - 001   - GM    -   26316   -  Fix Loading Configuration from file bug
2019.03.26  - 1.2.1     - 001   - GM    -   26312   -  Fix Configuration generation bug
2019.03.25  - 1.2.0     - 001   - GM    -   26136   -  Configurator multiple FW support (FMB/FMB640)
2019.03.22  - 1.1.6     - 005   - KM    -   26244   -  Spec ID 114 settinsg added for FMB207:6 HW option
2019.03.19  - 1.1.6     - 004   - AV    -   25459   -  Second minor fix of BT status io on some HW's
2019.03.19  - 1.1.6     - 004   - AV    -   25459   -  Fix BT Status IO element showing in configurator
2018.03.19  - 1.1.6     - 003   - AJ    -   25817   -  Remove repeating parameters for FMB125:34
										-   25882   -  Add missing tooltips for FMB130 GND sense and DOUT3.
										-   22884   -  Fixed odometer calculation source collection, removed iButton from deactivate by and removed RS485 mode from FMB207 configuration
										-   25855   -  Added UL202 collection and I/O element tooltips
										-   25858   -  Added UL202 support for FMB207 HW where it was missing.
                                - PD    -   24332   -  Fix Led Indication configuration for MTB device's.
2018.03.07  - 1.1.6     - 002   - AV    -   26020   -  Change Default Time Sync value for FW versions 03.25.02 and above
2018.03.07  - 1.1.6     - 001   - GM    -   25749   -  Fix Manual Geofence bug when Configurator was crashing while drawing shape which start point was null
										-	None	-  Fix Polygon Points count
2018.03.06  - 1.1.5     - 001   - GM    -   25671   -  Fix save current statuses to .html JS
										-	26015	-  Make Geozones Delay parameter visible for all types of Map Shapes
2018.03.05  - 1.1.3     - 001   - GM    -   25991   -  Fix Status window related issues (update, tabs dissapearance)
										-	None	-  Fix Status -> Maintenance brand buttons styles
										-	None	-  Fix Security -> Keyword / Toggle buttons styles
										-	None	-  Add Dynamic Table Header styles configuration into brand
2018.03.04  - 1.1.1     - 003   - AJ    -   25869   -  Added global speed source, bluetooth new conn mode, ble conn prohibit and UL202 support.
2018.02.28  - 1.1.1     - 002   - VB    -   25673   -  Added Tooltip AIS-140 settings
2018.02.28  - 1.1.1     - 001   - GM    -   24886   -  Add Polygon shape creation
										-	None	-  Update configurator .NET Framework to 4.5.2
2018.02.26  - 1.0.14    - 001   - LV    -   25307   -  Update "Read records without erase" feature
2018.02.26  - 1.0.13    - 001   - LV    -   25698   -  Fix long saving
2018.02.25  - 1.0.12    - 001   - LV    -   22225   -  Update versioning
2018.02.22  - 1.0.11    - 001   - GM    -   22225   -  Add label and tooltip versioning by Spec Id
2018.02.20  - 1.0.8     - 005   - SP    -   25617   -  Added FMB130 support.
2018.02.13  - 1.0.8     - 004   - AJ    -   25393   -  Added global speed source, new bluetooth configuration fields.
2018.02.13  - 1.0.8   	- 003   - AV    -           -  Fixed config bug which was made during changes in 1.0.8_C.002 version
2018.02.13  - 1.0.8   	- 002   - AV    -   25525   -  FMB125:34 and FMB125:36 support added for base 03.10.08
2018.02.12  - 1.0.8   	- 001   - GM    -   25560   -  Minor StateSwitchMasked control bugfix
2018.02.12  - 1.0.7   	- 001   - GM    -   25611   -  Fix Firmware Update for FMC640
										-   25592	-  Fix FMC640 Status window
										-	25560	-  Fix StateSwitchMasked control
										-	24968	-  Add ability to use VisibilityDependOnId on IO elements
2019.02.07  - 1.0.4     - 001   - GM    -   25204   -  Main release case
2019.02.06  - 1.0.3     - 001   - GM    -   25204   -  Main release case
2019.02.06  - 1.0.2     - 001   - GM    -   25204   -  Main release case
2019.02.01  - 1.0.1     - 001   - JB    -   23570   -  Fixed Trip Odometer and Total Odometer high level max values
2019.02.01  - 1.0.1     - 001   - GM    -   25204   -  Main release case
2019.02.01  - 1.0.0     - 001   - GM    -   25204   -  Main release case
2019.01.31  - 0.19.01   - 002   - AJ    -   25272   -  Added FMB207_30 (dual sim) HW support
2019.01.25  - 0.19.01   - 001   - GM    -   25258   -  Add Table control generation
2019.01.23  - 0.18.24   - 004   - AJ    -   25272   -  Added FM4001 HW support
2018.01.23  - 0.18.24   - 003   - MG    -   25148   -  MapmyInida name changed to AIS-140
2018.01.22  - 0.18.24   - 003   - MG    -   24706   -  Vehicle Reg. No. fix: length increased to 12
2018.01.22  - 0.18.24   - 003   - AV    -   24851   -  Tooltips for Eco/Green driving parameter fixed
2018.01.22  - 0.18.24   - 002   - MG    -   24668   -  MapmyIndia Alarm Period increased to 1s
2018.01.18  - 0.18.24   - 001   - GM    -   25204   -  Main release case
										-   24973	-  Add ability to define new IO element <CanSrc/>
										-	22836	-  Add Xim Minification support
										-	25070	-  Fix Spec Key back button colours
										-	25071	-  Fix Search for FM types splitted by ','
										-	25017	-  Fix bug occuring when saving configuration to file
2019.01.14  - 0.18.20   - 003   - GS    -   24563   -  Add new configuration to fix all mismatching offline and online parameter default values
2019.01.09  - 0.18.20   - 002   - GS    -   23806   -  Auto connect to external device missing parameter fix
2019.01.09  - 0.18.20   - 001   - GM    -   25024   -  Main release case
										-   19162	-  Add ability to define BT3/BT4 discovered lists tooltips
										-   25017	-  Fix bug occuring when saving configuration to file
										-   24610	-  Improve [Status Transfer Protocol] - extend status data parameter ID 2B ? 4B
2019.01.03  - 0.18.18   - 002   - MA    -   24464   -  Tool tip fix for ACK type and RS232 mode tooltip optimization.
								- MA    -   	    -  Fixed Domain regex for arobs IP.
								- MA    -   23280   -  Fixed parameter visibility bug.
								- MA    -   23707   -  Merging Traxgo spec configuration to base.
								- MA    -   22840   -  Merging Arobs spec configuration to base.
							    - MA    -   23975   -  Merging Commander to base.
2018.12.21  - 0.18.18   - 001   - GM    -   24842   -  Main release case
										-   24224	-  Add new feature [Regex validation]
										-	23665	-  Fix percentage shown while downloading (Dump) file
										-	22823	-  Add BT 4.0 vertical scrollbar
										-	24836	-  Add new feature [Ability to define image from Brand near list]
										-	24030	-  Fix counter shown while downloading accelerometer data
										-	23522	-  Increase default char size for RowNumberedTextBox autosize handler
										-	24849	-  Fix spec key back button display
										-	24848	-  Fix search textbox selection
										-	24130	-  Fix Units display of Battery voltage / Power voltage / Speed
										-	24865	-  Fix Unlock Required notification display
										-	24856	-  Fix bug when saving duoble/float values to CFG file / Device it was shown / saved as mathematic
										-	19217	-  Add DoutCtrl_DOUT2, DoutCtrl_DOUT2_only Collections tooltips
										-	24887	-  Add Brand traceability
2018.12.20  - 0.18.17	- 001   - KB    -   24836   -  iButton & 1-Wire views merged. Returned back iButton image for iButton lists
                                        -   24831   -  Dallas temp sensors config removed from FMB207 HW.
2018.12.18  - 0.18.15	- 001   - GM    -   24811   -  Fix bug when it was unable to load local Configurations, Localization
2018.12.14  - 0.18.14	- 003   - KB    -   24703   -  Merged with 1-Wire Dallas temp sensors locking feature branch (position configuration)
2018.12.14  - 0.18.14	- 002   - GM    -   20316   -  Fix Domain Regex Validation to accept IP's aswell
2018.12.14  - 0.18.14   - 001   - GM    -   24749   -  Main release case
										-   24154	-  Add Back button to Spec Key window
										-	20316	-  Add Regex validation to Domain fields
										-	24557	-  Rework Active Sim display
										-	24157	-  Sort configurations descending, sort FmTypes according to hardware.xml
										-	24299	-  Add new feature [SEARCH]
										-	21285	-  Fix bug when upon pasting values configurator was crashing
										-	20239	-  Add new feature [Detect Disconnect]
										-	18795	-  Fix bug occuring when pasting values to configurator
										-	23280	-  Add new feature [Enable/Disable on values]
										-	19203	-  Make geozone shapes use double types
2018.12.10  - 0.17.09	- 009   - JB    -23369,22872-  Fixed bad tooltips.
2018.12.06  - 0.17.09	- 009   - JB    -   23551   -  Removed battery specific config elements from HW's that don't support batteries.
2018.12.06  - 0.17.09	- 009   - JB    -22884,23823-  Fixed LVCAN distance source and RS485 tab for FMB207
2018.12.05  - 0.17.09	- 009   - MG    -   24344	-  LLS and Mercury removed from MapmyIndia configuration
2018.12.03  - 0.17.09	- 008   - JB    - (multiple)-  Multiple configuration (23464, 23269, 22921, 23270,  23548, 23563, 23284) and localization (22950, 23278) fixes
2018.11.29  - 0.17.09	- 008   - AA    -   24412   -  Changed several FMB devices names.
2018.11.28  - 0.17.09	- 007   - AF    -   23449   -  Applied (param def changes) for 03.18.16++ and 03.21.04++ versions properly.
2018.11.27  - 0.17.09	- 006   - AF    -   23449   -  Changed the default values of some parameters by TPP request.
2018.11.26  - 0.17.09   - 005   - GM    -   19217   -  Add Dout state ON and OFF labels and tooltips
2018.11.23  - 0.17.09   - 004   - AA    -   23449   -  Reverted C.003 commit
2018.11.22  - 0.17.09   - 003   - AF    -   23449   -  Amended the default parameters.
2018.11.19  - 0.17.09   - 002   - RV    -   23905   -  Fixed mistype in localization
2018.11.16  - 0.17.09   - 001   - AA    -   24137   -  Updated EXE to 0.17.09 version.
2018.11.15  - 0.17.06   - 004   - DA    -   23932   -  TMT250: Indication: Removed enable in sleep setting for sleep mode scenario.
2018.11.15  - 0.17.06   - 003   - GS    -   23545   -  Removed LLS 2/3/4/5 fuel level and temperature I/O elements for FMB207 with/without DOUT.
2018.11.14  - 0.17.06   - 002   - GM    -           -  Fix bug when Log4Net was not logging if app name was changed.
2018.11.13  - 0.17.06   - 001   - IB    -   23522   -  Updated EXE to 0.17.06 version.
2018.11.13  - 0.17.05   - 004   - KB    -   23945   -  Added missed changes from 22711: Added missed parameter "Detect International Number Type By Plus Symbol" for most FMB HWs
2018.11.13  - 0.17.05   - 003   - AA    -   24064   -  EXE title changed to: Teltonika.Configurator
2018.11.12  - 0.17.05   - 002   - AA    -   24064   -  Changed output configurator file names.
2018.11.09  - 0.17.05   - 001   - AA    -   23804   -  Updated EXE to 0.17.05 version.
2018.11.08  - 0.17.03   - 001   - MG    -           -  Accelerometer features config removed from spec 114/ fixed bkpSrvMode remove procedure.
2018.11.08  - 0.17.03   - 000   - DA    -           -  Updated EXE to 0.17.03 version.
2018.11.08  - 0.17.02   - 000   - DA    -           -  Updated EXE to 0.17.02 version.
--------------------------------------------------------------------------------
2018.10.23	- 0.16.01	- 062	- GS	- 	22840   -  Updated Localization missing min, max on tooltips, Configuration fixed versioning
2018.10.23	- 0.16.01	- 061	- GS	- 	22840   -  Updated arobs spec configurator with base 0.16.01_C.004
--------------------------------------------------------------------------------
2018.11.06  - 0.16.01   - 009   - DA    -           -  TMT250: Fixed critical bug where configurator crashes because it does not found collection reference. Also removed unused Guid and parameter ID description from localization.
2018.11.05  - 0.16.01   - 008   - DA    -           -  TMT250: Removed alerm feature enable parameter because this feature is enabled, when button is configured for alarm;
                                                    -  TMT250: Indication: Changed scenarios LEDs and vibro configuration to by one configurable parameter and added protection from no LED and vibro configuration.
2018.10.31  - 0.16.01   - 007   - AA    -           -  Merged with master_stable configurator: FMB.Configurator_v0.15.31.14912_C.008
2018.10.30  - 0.16.01   - 006   - MA    -   23834   -  Fixed RS485 Mode groups visibility.
                                - MA    -   23834   -  Fixed Traxgo RS232 delimiter parameter visibility.
2018.10.26  - 0.16.01   - 005   - MA    -   23276   -  Fixed alcotester configuration.
2018.10.22  - 0.16.01   - 004   - AF    -   22767   -  GUI: Max Cornering value (rad/s or m/s^2) depends no Green driving source (GPS or Accelerometer)
2018.10.22  - 0.16.01   - 003   - AA    -           -  Mini cleanup @ BaseExtensions.xml
2018.10.17  - 0.16.01   - 001   - MA    -           -  Release FMB.Configurator_0.16.01_C.001
                                - JK    -   23432   -  Changed default parameter "Power On By Charger" default value to 1.
                                - JK    -   23405   -  removed doubled parameter "Movement Settings".
                                - MA    -   23424   -  Updated EXE to 0.16.01 version.
                                - JK    -   23436   -  Connection mode doubling removal.
                                - JK    -   23393   -  User interface missing text fix.
--------------------------------------------------------------------------------
2018.10.15  - 0.16.00   - 160   - UB    -   22183   -  Updated configurator for Traxgo 107 spec.
--------------------------------------------------------------------------------
2018.10.15  - 0.16.00   - 025   - JK    -           -  Enabled Bluetooth 4.0  and its IOs for TMT250.
2018.10.12  - 0.16.00   - 024   - JB    -   22818   -  Increased odometer max value from 999999 to 4294967 (mantis: 22818)
2018.10.12  - 0.16.00   - 023   - AA    -   21746   -  Fixed OBD engine oil temp IO config (low/hi level).
2018.10.11  - 0.16.00   - 022   - AA    -           -  Fixed configurator crash for FMB207_21 and added trip speed source for: FMB9:23,MTB1:1 (storageless).
2018.10.11  - 0.16.00   - 021   - RV    -           -  Returned Message Timestamp parameter visibility for RS232 TCP Ascii Buffered mode
2018.10.11  - 0.16.00   - 020   - AA    -   22493   -  Updated EXE to 0.16.00 version.
--------------------------------------------------------------------------------
2018.10.29  - 0.15.31   - 083	- MA    -   23755   -  Releasing configurator FMB.Configurator_0.16.01_C.070
								- MA    -   23766   -  Fixed voice alarm parameters unit.
2018.10.19  - 0.15.31   - 082   - MA    -   23583   -  Changed LVCAN fuel level value multiplier for commander spec.
2018.10.12  - 0.15.31   - 081   - MA    -   23446   -  Fixed wrong commander configuration/localization.
2018.10.04  - 0.15.31   - 081   - MA    -   22050   -  Fixed spec:105 ibutton configuration.
2018.01.01  - 0.15.31   - 080   - MA    -   23076   -  Merge base configurator
--------------------------------------------------------------------------------
2018.10.11  - 0.15.31   - 020   - KB 	-   22711   -  Added missed parameter "Detect International Number Type By Plus Symbol" for most FMB HWs
                                        -   23426   -  Fixed Detect International Number Type By Plus Symbo parameter UI rendering
2018.10.09  - 0.15.31   - 006   - KB 	-   20677   -  Fixed exception generation at FW Update procedure if used SETUP version
2018.10.09  - 0.15.31   - 005   - MM 	-   23334   -  Added parameters for FMB920_51.
2018.10.08  - 0.15.31   - 005   - UB    -           -  Updated configurator.
2018.09.20  - 0.15.24   - 012   - MM    -   22900   -  Added TMT250 Power Saving functionality.
                                                    -  Fixed Trip Speed Source tooltips.
										-   22972   -  Implemented Order Priority functionality on TMT250.
										-   22244   -  Added exclusive ggps and getgps sms commands and configurable sleep exit source on TMT250.
2018.09.20  - 0.15.24   - 012   - DA    -   21543   -  Fixed tool tips for all indication scenarios and GSM Settings group boxes.
2018.09.20  - 0.15.24   - 011   - GS    -   22959   -  Added EGTS support
2018.09.21  - 0.15.24   - 010   - GS    -   20205   -  Added missing hw (fmb207, fmb125 ble dual sim) support for spec 110.
2018.09.18  - 0.15.24   - 009   - GS    -   18391   -  Updated missing tooltips v2.
2018.09.18  - 0.15.24   - 008   - GS    -   18391   -  Updated missing tooltips.
2018.09.17  - 0.15.24   - 007   - AA    -   22170   -  Reverted odometer_value changes.
								- GS    -   22911   -  Removed ble control -> prohibit parameter (it is not yet implemented in FMB base).
2018.09.14  - 0.15.24   - 006   - GS    -   18391   -  Localization improvements
2018.09.11  - 0.15.24   - 005   - JB    -   22170   -  Increased min odometer value from 0 to 1.
--------------------------------------------------------------------------------
2018.09.28  - 0.15.24	- 081	- MA    -			-  Updated configuration to FMB.Configurator_v0.15.24.17030_C.014
2018.09.25  - 0.15.24	- 080	- GS    -	23057	-  Added missing voice alarm feature for fmb125 in configuration
										-	23078	-  Added FMB100/FMB110 BLE hw support for spec_105 in configuration
										-	23084	-  Removed crash trace function dublicate in configuration
										-	23085	-  Moved "Number Check Settings" from Base to BaseExtension
										-	23059	-  Added missing tooltip for passenger ibutton list in localization
2018.09.19  - 0.15.24	- 079	- AA    -			-  Fixed parameter_id overlap [60040..60055] => [60200..60215] (105 vs 110)
2018.09.19  - 0.15.24	- 078	- AA    -			-  Updated commander spec configurator with latest base configuartor: 0.15.24_C.009
2018.09.11  - 0.15.24	- 077	- AA    -			-  Updated commander spec configurator with latest base configuartor: 0.15.24_C.004
--------------------------------------------------------------------------------
2018.09.07  - 0.15.24	- 004	- KB    -			-  Changed TZ-BT04 Update frequency min value.
2018.09.07  - 0.15.24	- 003	- MG    -	22237	-  Removed unnecessary options from MapmyIndia configuration
										-	22235	-  Autogeofence option removed also
											22218	-  localization update: Max and min values added to tooltips for MapmyIndia
											22217	-  Battery values changed for MapmyIndia project
2018.09.07  - 0.15.24	- 002	- KB    -			-  Added new LVCAN IOs U193
2018.09.07	- 0.15.24	- 001	- GS	-	18391	-  Updated EXE to 0.15.24 version; Updated localization file for min/max/default.
--------------------------------------------------------------------------------
2018.09.04  - 0.15.18	- 131	- MM    -	    	-  Added Battery Current and Speed IO elements for TMT250.
2018.08.31  - 0.15.18	- 130	- MM    -	22160	-  FMB Release 03.19.00.Rev.00:
										-	21287	-  Added 4000 iButton support.
										-	21287	-  BLE Efento sensors support
										-	21287	-  Added ACK Type parameter.
										-	21287	-  Added Trip speed source parameter.
										-	21491	-  Added Banlist.
--------------------------------------------------------------------------------
2018.09.06  - 0.15.23	- 001	- KB    -	21129	-  Updated EXE to 0.15.23 version
2018.09.05  - 0.15.12	- 001	- KB    -	21129	-  Separated Movement Delay config. Added 3.23 config (new IO, EcoAvg + AcoMax config params for FMT1)
                        - 002   - KB    -   21129   -  Changed Accelerometer Delay settings tooltips
2018.08.28  - 0.15.12	- 101	- DA    -	22562	-  Fixed Spec IDs 107 and 121 (currently not in base) RS232 baudrate duplication.
--------------------------------------------------------------------------------
2018.09.06  - 0.15.12	- 060	- IB    - 22382	    -  Updated configurator.
2018.08.10  - 0.14.07	- 051	- IB    - 22054	    -  Arobs Green Drving parameters.
2018.07.26  - 0.14.07	- 050	- IB  - 22054/21784	-  Arobs DOUT by GNSS parameters.
--------------------------------------------------------------------------------
2018.08.27  - 0.15.12	- 100	- AA    -	22292	-  Updated EXE to 0.15.12 version.
2018.08.24  - 0.15.10	- 100	- DA    -	22184	-  RS232: added new mode Mercury C4, added new baudrate 4800; Immobilizer: Added alcotester chec settings, added new IO element configuration for alcotester.
2018.08.24  - 0.15.10	- 100	- AA    -	22292	-  Merged master_fota_web_ext branch with crash_improvements_v2 branch.
--------------------------------------------------------------------------------
2018.08.20  - 0.15.10	- 100	- RV    -			-  Updated EXE to 15.10 version + fixed installer creation (include missing dlls to installer)
2018.08.20  - 0.15.08	- 100	- RV    -			-  Updated EXE to 15.08 version
--------------------------------------------------------------------------------
2018.08.20  - 0.15.06	- 101	- AA    -	22275	-  Added missing dlls.
2018.08.10  - 0.15.06	- 100	- AA    -	22275	-  Updated EXE to 15.06 version.
--------------------------------------------------------------------------------
2018.08.07  - 0.15.04	- 100	- AA    -	22127	-  Updated EXE to 15.04 version.
--------------------------------------------------------------------------------
2018.08.07  - 0.15.03	- 101	- AA    -	22127	-  Updated configuration/localization submodules (merged them withm corresponding master branches).
2018.08.06  - 0.15.03	- 100	- KB    -	22127	-  Added OBD, LVCAN Fault Codes IO elements
                                                    -  Updated EXE to 15.03 version:
														* Fix security window refresh on simOperations http://192.168.3.252/mantisbt/view.php?id=19743
														* Add window freeze during the simOperations
														* Add check for StatusProtocolFeatures.Mqtt in order to read certificates
														* Fix save current statuses to .html http://192.168.3.252/mantisbt/view.php?id=21077
														* Fix casting exception in ShapeConstructor
														* Fix null reference exception in DeviceInternalStatusesViewModel
														* Add temporary support for FMB640 status transfer protocol versioning (StatusCommands)
														* Add support for Status window displaying for FMB640
														* Add manual can configuration feature.
														* Allow integer value input in hexadecimal notation
														* Add additional elements to represent satellites currently in use. http://192.168.3.252/mantisbt/view.php?id=21322
														* Fix status -> gnss -> satellites elem
--------------------------------------------------------------------------------
2018.07.26  - 0.14.10	- 100	- KB    -	21939	-  Updated EXE to 14.10 version:
														Fix Status -> Can Adapter view disappearance when device fails to pull values.
														Fix TMT250 failed to read configuration after firmware updatre. 21646
														Fix Int32 max values for I/O UI controls. 21560
														Fix LLS bug that prevented configuration saving to the device. 21560
--------------------------------------------------------------------------------
2018.07.26  - 0.14.07	- 101	- MG    -	21179	-  ServProtocol is removed from spec 114 configuration.
2018.07.20  - 0.14.07	- 100	- MG    -	21645	-  Configuration for FMB9:22/FMB9:21 added (for proper NAND detection).
2018.07.20  - 0.14.07	- 100	- MG    -			-  Updated EXE to 14.07 version.
										-	20911	-  CAN parameters showing in status window fixes
										-	21423	-  GSM info faulty IP/Port showing fix.
--------------------------------------------------------------------------------
2018.07.19  - 0.14.05	- 107	- MG    -	21592	-  Battery Level % and BT status Tooltips added.
2018.07.10  - 0.14.05	- 106	- MG    -	21504	-  Matrix spec ID related parameters added.
2018.06.22  - 0.14.05	- 105	- KB    -	21402	-  Added CNG status, CNG Used, CNG Level, Oil Level for FMB1xx 33,55 HWs
2018.06.22  - 0.14.05	- 105	- KB    -	20721	-  Added new parameters: BT Status IO and Inateck Scanner mode. Updated Localization
--------------------------------------------------------------------------------
2018.08.14  - 0.14.05	- 156	- IB    -	22262	-  FMT100 Driving State IOs.
2018.08.03  - 0.14.05	- 155	- AS    -	21695	-  Merged all axl to one crash processing algorithm.
2018.07.16  - 0.14.05	- 154	- SP    -	21618	-  Merged with FMB.Configurator_v0.14.5.27701_C.152(Trace ODR).
2018.07.09  - 0.14.05	- 153	- SP    -	21618	-  Updated Crash trace help tool tip.
2018.06.29  - 0.14.05	- 152	- AS    -	20052	-  Added AXL data down sampling option for KX023/LIS3DH/DA217 devices.
2018.06.21  - 0.14.05	- 151	- SP    -	20874	-  Added crash trace parameter for FMB001 buzzer.
2018.06.21  - 0.14.05	- 150	- SP    -	20874	-  Changed crash trace enable parameter to crash trace mode parameter.
--------------------------------------------------------------------------------
2018.06.21  - 0.14.05	- 104	- AA    -	21209	-  Merged with master branch version: 0.14.05_C.001
--------------------------------------------------------------------------------
2018.06.14  - 0.14.03	- 103	- AA    -	21209	-  Preparation for FMB.Ver.03.15.00 release:
														Merged spec/geocapture (119) spec branch additions.
														Merged EuropeTrack_sp116 spec branch additions.
														Merged dev/ignitiontmo branch additions.
														Merged fmt100_fw_upgrades branch additions.
								- IB    -	19436	-  Added BLE Power Level parameter
--------------------------------------------------------------------------------
2018.06.14  - 0.14.05	- 001	- AS    -	20073	-  Updated EXE to 14.05 version.
--------------------------------------------------------------------------------
2018.06.14  - 0.14.03	- 003	- KB    -	21180	-  Added FMB964 DualSIM HW support
2018.06.12  - 0.14.03	- 002	- KB    -	21203	-  Added FMB125 BLE DualSIM HW support
--------------------------------------------------------------------------------
2018.06.11  - 0.14.03	- 100	- AA    -			-  Removed beltrans spec from master_fota_web_ext configurator branch.
													   Added spec/NaviGo branch (unplug->make call) params.
													   Added Zeekit_110 branch. Spec fw support.
													   Added Battery level percentage IO for all HW's with battery.
2018.06.04  - 0.14.01	- 050	- AS    -			-  Added BelTransSputnik spec id 118.
--------------------------------------------------------------------------------
2018.05.30  - 0.14.03	- 001	- KB    -	20912	-  Removed LVCAN option from Odometer Distance Source parameter
                                        - 	21149	-  Updated EXE to 14.03 version:
										                 Fix dump download bug. Ignore failed to download dump file, continue with next file download.
														 Increase request 0x0028 timeout to 60s
														 Fix default min/max value converting bug. 21062
														 Fix evaluation bug of parameter minimum and maximum values based on another parameter value. 20823
--------------------------------------------------------------------------------
2018.06.04  - 0.14.00	- 117	- RV    -			-  Changed DIN4 parameters IDs.
2018.05.28  - 0.14.00	- 116	- MG    -	17968	-  Added MapmyIndia spec 114 functionality.
2018.05.28  - 0.14.00	- 115	- KB    -			-  Fixed .EXE generation script
2018.05.28  - 0.14.00	- 114	- AA    -	20752	- Fixed tooltip error. Merged master_fota_web_ext branch configurator with master branch.
--------------------------------------------------------------------------------
2018.05.30  - 0.14.00	- 004	- RV    -	20682	-  Unified representation of some parameters on different HWs
2018.05.30  - 0.14.00	- 003	- KB    -	20902	-  Fixed FW Update problem, caused by .NET release mistake
2018.05.28  - 0.14.00	- 002	- KB    -			-  Fixed .EXE generation script
2018.05.23  - 0.14.00	- 001	- KB    -	20073	-  Updated EXE to 14.00 version:
													   Allow keyword saving to file when using offline configuration mode.
													-  Fix bug when in offline configuration mode after loading configuration from file user was notified that loaded keyword doesn't match keyword set on device.
										-	19203	-  Fix wrong coordinates rounding (case retured).
--------------------------------------------------------------------------------
2018.05.24  - 0.13.40	- 113	- MA    - 			- Fixed Data Protocol configuration parameter for Traxgo spec func.
2018.05.24  - 0.13.40	- 112	- MA    - 			- Updated .exe files
2018.05.23  - 0.13.35	- 112	- MA    - 			- FMB207 support from 3.14.00 condifuration version
2018.05.22  - 0.13.35	- 111	- MG    - 			- Merged FMB207 branch
2018.05.16  - 0.13.35	- 110	- AA    - 	19337	- 01.11.00 FW release + configurator changes:
														Merged base configurator branch with: TrackIT_Traxgo + FMT100
								- RV    - 	19020	- Allowed not to enter VIN number for ELD functionality.
--------------------------------------------------------------------------------
2018.05.23  - 0.13.35	- 001	- RV    -	20615	- Fixed LVCAN Fuel Level value coefficient, according to IO protocol (was not multiplied by 10)
2018.05.22  - 0.13.35	- 001	- RV    -			- Changed Odemeter max value due to overflow during configuration..
2018.05.17  - 0.13.35	- 001	- RV    - 	19020	- Allowed not to enter VIN number for ELD functionality.
2018.05.15  - 0.13.35	- 001	- SP    - 	17885	- Exe update to Configurator_0.13.35.
--------------------------------------------------------------------------------
2018.05.14  - 0.13.31	- 004	- SP    - 	17885	- Added ibtn read notification Depend on ignition for all hw's.
2018.05.09  - 0.13.31	- 003	- KB    - 	20442	- Fixed LVCAN Engine Temperature value coefficient, according IO protocol (not multiplied by 10)
2018.05.09  - 0.13.31	- 002	- SP    - 	17885	- Merged FMB.Configurator_0.8.54.0_C.020 into master(iButton notification section "Depend On Ignition").
2018.05.07  - 0.13.31	- 001	- KB    - 	19988	- Updated to 13.31:
														Fix dependencies list containing duplicate keys. 20340
--------------------------------------------------------------------------------
2018.05.07  - 0.13.30	- 005	- RV    - 	19020	- ELD functionality merged in.
2018.05.03  - 0.13.30	- 004	- SP    - 	19354	- Added Ain1 units for fmb2.
2018.04.26  - 0.13.30	- 002	- AS    - 	20104	- TZ-BT05B hardware detection added.
2018.04.06  - 0.13.30	- 002	- KB    - 			- Merged with CAN_CONTROL branch. Added configuration for CAN-CONTROL FW
--------------------------------------------------------------------------------
2018.04.24  - 0.13.30	- 001	- RV    -			- Updated exe to 13.30 version:
										-	20181	- * Fix wrong  wrap panel calculations.
										-	19772	- * Fix home screen not updating visible devices.
										-19988/19989/20129	- * Fix reboot waiting bug.
															- * Fix dependencies list containing duplicate keys.
															- * Change UI.Core/Communications/Events folder structure.
2018.04.24  - 0.13.27	- 002	- MA    - 	17538	- Jamming DOUT control max value adjusted.
2018.04.18  - 0.13.27	- 001	- KB    - 	19789	- Updated exe to 13.27 version:
										-	19283	-	* Fix RS232 settings display.
										-	19819	-	* Fix cannot configure low voltage.
										-	19952	-	* Fix confusing display of connected devices.
2018.04.13  - 0.13.24	- 001	- KB    - 	19789	- Updated exe to 13.24 version:
														Fix rarely occuring bug when deleting temp folder of dump files download. 19837
														Refactor structure of DiscoveringService folder.
														Add digits limit in Sms/Call Settings tab
														Fix digits limit in GSM Operatos tab
2018.04.10  - 0.13.22	- 004	- MG    - 	19224	- Merge Network Ping Timeout functionality branch to base.
2018.04.06  - 0.13.22	- 003	- AA    - 			- Added proper FMT1 image.
2018.04.05  - 0.13.22	- 002	- AA    - 	19579	- Added FMT100 HW support.
2018.04.03  - 0.13.22	- 001	- KB    - 	19579	- Updated EXE to 13.22:
														Added BluetoothDeviceMonitor for speeding up device detection.
														Bluetooth/COM firmware update performance optimization.
														Bluetooth/COM device discovery service performance optimizations.
														Fix UartBootModeSetOperation - Return failure if after 4 attempts uart boot mode not enetered.
														Fix LLS control (at same time Dallas Temperatures control was fixed, too). 17650
														Refactor PropertyVault class
2018.03.23  - 0.13.17	- 003	- KB    - 	19463	- Fixed LVCAN Program Number MAX value
2018.03.19  - 0.13.17	- 002	- KB    - 	18228	- Corrected FW versions - Configuration sequence.
2018.03.09  - 0.13.17	- 001	- MG    - 	19136	- Updated exe to 0.13.17. Location status hyperlink fix/ default values loading setting fail fix
2018.03.08  - 0.13.11	- 002	- AF    - 	17801 	- From Spec ID 100 is removed FMB125I; To Spec ID 101 added FMB964.
2018.03.06  - 0.13.11	- 001	- AS    - 	18707	- Updated exe to 0.13.11. BLE device list copy functionality implemented.
										-	17403	- Show FW version with revision.
--------------------------------------------------------------------------------
2018.03.02  - 0.13.08	- 001	- KB    - 	19061	- Updated exe to 0.13.08. Fix help box (F1) not displaying text.
2018.03.02  - 0.13.07	- 001	- KB    - 	18971	- Updated exe to 0.13.07. Fix list import exception "Object of type 'System.String' cannot be converted to type 'System.Int.32'"
2018.03.02  - 0.13.06	- 001	- KB    - 	19022	- Updated exe to 0.13.06. Fix :cfg_setparam: commands spliting.
2018.02.27  - 0.13.05	- 001	- KB    - 	18678	- Updated exe to 0.13.05.
										-	18839	- Fixed certificates' downloading settings tooltip http://192.168.3.252/mantisbt/view.php?id=18839
										-	18074	- Make port discovering more frequent
										- 	18901	- Minor UI corrections.
										-   18872	- Added missed OP LIST 100 for SPEC 101
										            - Fixed certificates' downloading settings tooltip
--------------------------------------------------------------------------------
2018.02.22  - 0.13.02	- 001	- AA    - 	18678	- Updated exe to 0.13.02.
										-	17984	- From 0.13.0 added: Dallas Temperature sensors Id configuring.
--------------------------------------------------------------------------------
2018.02.21  - 0.11.02	- 001	- AA    - 	18678	- Updated exe to 0.11.02.
2018.02.19  - 0.11.01	- 001	- RV    - 			- Changed AND to OR in Ignition settings parameter tooltip description.
2018.02.19  - 0.11.01	- 001	- KB    - 	18686	- Added FMB100/ FMB110 33 HW. Improved the RS232/RS485 config UI.
													- Updated exe to 0.11.01:
														Added images for missing FMB devices
														Minor refactoring
														Removed locks functionality because it does not work properly
														Fix read records UI aligment
														Show valid/corrupted record count
														Receive record valid/corrupted count during read records
2018.02.09  - 0.10.30	- 001	- KB    - 			- Updated exe to 0.10.30.
										-   16054   - Fix active SIM parsing.
										- 	18678	- FMB120_BLE/Can not configure green driving. Fix problem with saving parameters when using non english windows localization.
										- 	13583	- MessageBox to download lacked framework 4 update on Windows XP. Added new reference Microsoft.Deployment.WindowsInstaller
										-	13583	- Setup deploy for Windows XP
										-	18509	- Fix FW flashing error (read timeout for serial port was 1ms, increased to 500ms)
2018.02.09  - 0.10.25	- 002	- RV    - 	17297	- Removed SD Status from FM3xxx HWs (HWs with NAND).
2018.02.08  - 0.10.25	- 001	- KB    - 	18509	- Updated exe to 0.10.25. Fix null reference exception when disconnecting from offline configuration.
2018.02.06  - 0.10.24 	- 001	- KB    - 	18436	- Updated exe to 0.10.24. Fixed config file for FMB1_33 HW. 18602, 18601
											17650		* Changed default directory for saving logs and downloaded certificates to My Documents 18212
											17719		* Implement Mutex for port occupation (when running multiple instances of configurator, they "race" for new ports. Whichever takes it first, other instances display error). 17719
											17650		* Fix LLS RS485 sensors control in RS232\RS485 tab. 17650

2018.01.29  - 0.10.20 	- 001	- KB    - 			- Updated exe to 0.10.20. Fixed mantis
														*Modify base configuration (Condigurations submodule) to change minimum validatin value for autogeofence radius. http://192.168.9.100/mantisbt/view.php?id=18230
														*Fix "Access to port 'COM_X' is denied". http://192.168.9.100/mantisbt/view.php?id=17727
														*Fix: 0017985: ilgai trunka copy paste 1000 iButton listui
														* Messenger optimization
														* Replaced ByteToValueConverter
														* Refactored XML serialization classes
														* Optimized RowNumberTextBox control (copy/paste operations).
														* Replaced ObservableCollection<AdvancedFeature> with FeatureCollection
														* Fix disabled disconnect button in ofline configuration.
										- 17264     - Added PAP/CHAP parameters
2018.01.26  - 0.10.17 	- 001	- AA    - 			- Updated exe to 0.10.17. Fixed mantis: 18251, 18284, 18276, 18385. See changelog.txt.
2018.01.25  - 0.10.12 	- 001	- RV    -			- Updated Ultra Sleep tooltip.
2018.01.24  - 0.10.12 	- 001	- AA    - 18252		- Updated exe to 0.10.12. Duplicate case of: 18312. Fixed issue with not english language windows. I.e. turkish etc. Then configurator could not find FMB devices.
2018.01.23  - 0.10.9 	- 001	- KB    - 18312		- Updated exe to 0.10.9. 18252, 18312
                                                      Fix bug: NullReferenceException in ListControlBase<>.Values_CollectionChanged
                                                      Fix bug: After device with unsupported spec id is attached print to log that device is not supported.
										- 17739     - Added Ultra Deep Sleep
										- 18270     - Fixed setup generation
2018.01.23  - 0.10.8 	- 001	- AA    - 18321		- Updated exe to 0.10.8. Fixed FM3 configuration. Updated localization with V.Fomcenko changes.
										- 18323		- A.Simkunas added missing tooltips. Localization file changes.
2018.01.19  - 0.10.5 	- 002	- AS    - 17491		- Merged zeekit spec functionality to master branch.
2018.01.19  - 0.10.2 	- 003	- RV    - 17297		- Updated exe to 0.10.5 + added new HW pictures
2018.01.19  - 0.10.2 	- 003	- RV    - 17297		- Shortened label to be fully visible
2018.01.18  - 0.10.2 	- 002	- RV    - 17297		- Added new HWs support
2018.01.18  - 0.10.2 	- 002	- RV    - 17603		- Updated IO elements with units
2018.01.17  - 0.10.2 	- 001	- AA    - 17743		- Updated exe to 0.10.2
2018.01.17  - 0.10.1 	- 001	- AA    - 17965		- Updated exe to 0.10.1
2018.01.15  - 0.10.0 	- 003	- AA    - 17689		- Localization changes according to mantis (by Fomcenko).
2018.01.15  - 0.10.0 	- 002	- KB    - 			- Deploy.wxs changes
2018.01.12  - 0.10.0 	- 001	- AA    - 17448		- Updated exe to 0.10.0. MQTT certificate files download to device functionality support was implemented.
---------------------------------------------------------------------------------
2018.01.12  - 0.9.2 	- 004	- AA    - 18249		- FMB0:3 FMB001 configuration added
2018.01.11  - 0.9.2 	- 003	- AA    - 17446		- Fix ble io hiding.
2017.12.21  - 0.9.2 	- 002	- SP    - 17983		- Fix iButton list config according to mantis 17983
2017.12.21  - 0.9.2 	- 001	- KB    - 18040		- Fixed "Dout on duration" MIN/MAX values
                                                    - Fixed bug when saving dump with subdirerctories
													- Dout group box hiding if Douts == 0, Read Acc data time changed to seconds
                                                    - Updated exe to 0.9.2. Fixed 17980
										- 18032     - Removed DOUT2 from FMB125 HWs
---------------------------------------------------------------------------------
2017.12.21  - 0.8.77	- 001	- KB    -			- Updated exe to 0.8.77. Fixed 18041, 18029, 16054, 17983
                                                    - Fixed bug during FW update cancellation
													- Fixed bug in property vault. Properties were modified if not loaded from device
													- Added deployment via WIX SETUP script with branding support. Adopted release.bat
2017.12.20  - 0.8.73	- 001	- MG    -			- Updated exe to 0.8.73
2017.12.19  - 0.8.72	- 001	- KB    -			- Updated exe to 8.72. Fixed 17985, 17981, 17999, 17962, 17967, 17982. Fixed IO BLE hiding.
2017.12.15  - 0.8.70	- 001	- KB    -			- Updated exe to 8.70. Fixed 17749, 17745, Fixed 2 steps FW updated
2017.12.14  - 0.8.67	- 001	- KB    -			- Updated exe to 8.67. Updated localization. Fixed 17753.
                                                    - Added "%gmap" tag for SMS events text configuration tooltips
2017.12.08  - 0.8.66	- 001	- KB    -			- Updated exe to 8.66. Added missing tooltip to DA
2017.12.08  - 0.8.65	- 001	- AA    -			- Updated exe to 8.65. See changes 54->65 in ChangeLog.txt
2017.11.30  - 0.8.54	- 001	- RV    - 17649		- Fixed DIN2 tmo min value for spec 103
										- 17495		- LVCAN program number max range extended to 9999
2017.11.24  - 0.8.54	- 001	- KB    - 17261		- Updated exe to 8.54 to solve 17261 (old<-> new branches update)
2017.11.22  - 0.8.53	- 002	- KB    - 			- Added package to allow do downgrade procedure from 03.00.00 - 03.03.00 to 01.03.13 FW.
2017.11.21  - 0.8.53	- 001	- AA    - 			- Updated exe to 8.53. See changes 49->53 in ChangeLog.txt. Fixed mantis: 17033, 17291, 16870, 17261.
2017.11.20  - 0.8.49	- 001	- RV    - 17482		- Removed LVCAN option from Trip/Odometer calculation source parameter for HW FM3001
2017.11.14  - 0.8.49	- 001	- KB    -			- Updated exe to 8.49. Fixed Mantis:17532, 17009, 17441
2017.11.13  - 0.8.48	- 001	- AA    -			- Updated exe to 8.48. See changes 42->48 in ChangeLog.txt
2017.11.10  - 0.8.42	- 001	- AA    -			- Updated exe to 8.42. See changes 41->42 in ChangeLog.txt
2017.11.09  - 0.8.41	- 001	- AA    -			- Updated exe to 8.41. See changes 34->41 in ChangeLog.txt
2017.11.09  - 0.8.34	- 002	- RV    - 16516		- Fixed Recs saving/sending without TS parameter configuration in different CFG versions
2017.11.06  - 0.8.34	- 001	- AA    -			- Updated exe to 8.34:
										- 17200			* Boris fixed last RS232/RS485 packet display @ maintenance.
										- 15739			* Boris added lls calibration
										- 17273			* Matas fixed to log dump functionality
										- 16907			* Matas changed status transfer data types 0x07 visualization to 0x...
2017.11.03  - 0.8.30	- 002	- EV    -           - Added SATIS spec FW configuration with 103 spec par ID
2017.11.02  - 0.8.30	- 001	- KB    -           - Updated exe to 8.30:
														*Fixed http://192.168.3.252/mantisbt/view.php?id=17204
														** If archive is opened in other program user wil be notified that configurator failed to save data
														** Added date, time and export type(log/dump) to filename
														** Minor UI changes in settings view, export notification view
														* Fixed http://192.168.3.252/mantisbt/view.php?id=17344
														* Fixed http://192.168.3.252/mantisbt/view.php?id=17048
														* Fixed http://192.168.3.252/mantisbt/view.php?id=17280
														** Configurator not crashing when device with SpecId is connected
														** Configurator not crashing when entered invalid SpecId Key
														* It is now possible to add <Placeholder/> and <UiControl/>. http://192.168.9.100/mantisbt/view.php?id=17129
														* Based on ReSharper suggestions, in various reduced nesting, changed single-line "if" clauses to multi-line (improves readability).
2017.10.27  - 0.8.27	- 007	- RV    -           - Updated SMS Text tooltips
2017.10.27  - 0.8.27	- 007	- KB    -           - Changes from config 3.6 moved to 3.5
2017.10.27  - 0.8.27	- 006	- RV    -  17237    - Updated CAN speed tooltip
2017.10.27  - 0.8.27	- 005	- RV    -  17013    - Updated SMS Text tooltips with composed SMS description
2017.10.26  - 0.8.27	- 004	- EV    -  15893    - Added green driving duration parameter
2017.10.25  - 0.8.27	- 003	- RV    -  15893    - Added missing Immobilizer SMS paremeters related labels and tooltips.
2017.10.24  - 0.8.27	- 002	- RV    -  17228    - Added missing Advanced Trip Settings and Odometer sections in Trip/Odometer tab.
2017.10.24  - 0.8.27	- 001	- AA    -  16882    - Updated exe to 8.27. Changes:
														* 0.8.25 Added dump files download @ status transfer protocol.
														* 0.8.26 Bugfixing for dump files download; Mantis 15739 bugfixing.
														* 0.8.27 Mantis 16907 bugfix.
2017.10.18  - 0.8.24	- 007	- RV    -  16882    - Added LVCAN Tachograph Vehicle Speed Averaging Constant.
2017.10.13  - 0.8.24	- 006	- KB    -  16826    - Changes from config 3.6 moved to 3.5
2017.10.13  - 0.8.24	- 005	- EV    -  16826    - ibutton notification on timeout parameter max value changed
2017.10.10  - 0.8.24	- 004	- EV    -  16826    - Added iButton notification for ibutton list.
2017.10.10  - 0.8.24	- 003	- KB    -  17039    - Fixed Idling detection Max and Default values.
2017.10.09  - 0.8.24	- 002	- RV    -  16666    - Added missing Battery Voltage/Current IO elements for FMB120/122/125
										-  16878	- Changed Dallas Temperature IO elements high/low level ranges
										-  16954    - Removed Calculation Source parameter for FMB010 HW
2017.10.06  - 0.8.24	- 001	- KB    -           - Updated exe to 8.24. Changes:
														* Added SpecId registration
														* Fixed acc capture countdown if not supported
														* Added default dir for log/dump/acc capture
														* Added open log/acc dir buttons
														* Added new view creation on change
														* Fixed 16974, 16869, 16867
														* Added log reading from device
														* Added accelerometer data reading from device
														* Added RS232/485 status
														* Added DOUT toggle
2017.10.06  - 0.8.24	- 001	- RV    -15984/16619- Added 2 RS232 buffered modes + parameter Message Timestamp
2017.10.03  - 0.8.19	- 002	- AA    - 			- Included localization changes by Boris
2017.09.29  - 0.8.19	- 001	- KB    - 16919		- Updated exe:
													- IO stateswitch width fix, Fixed StateSwitch datatemplate bug, Added configuration export on Ctrl + Alt + Shift + Click
													- Mantis: 16868, 16882, 16891
													- Added missing localization values
													- Updated localization implementation, Minor bug fixes
													- Some sizes of controls can be set through localization. If not set, default values will be used
										- 16933		- Added New LVCAN IOs: CNG Status, CNG Used, CNG Level, OIL Level.
2017.09.12  - 0.8.15	- 001	- KB    - 16720		- Updated exe: Added RU localization, improved communication with device (decreased tmo), changed images. 16658
2017.09.18  - 0.8.13	- 008	- RV    - 16563		- Removed Deactivated by from Auto Geofence for FM30YX HWs.
2017.09.18  - 0.8.13	- 007	- RV    - 16565		- Added Network Type IO element for FM30YX HWs.
2017.09.18  - 0.8.13	- 006	- AA    - 16623		- Fixed 807 param for old and new versions.
2017.09.15  - 0.8.13	- 005	- SP    - 14691		- Added AROBS link status dout ctrl parameters.
2017.09.15  - 0.8.13	- 004	- DA    - 15935		- Fixed spelling
										- 16503		- Added new parameter ID BaudrateNmea and renamed parameter Baudrate to BaudrateFull.
2017.09.14  - 0.8.13	- 003	- RV    - 16623		- Removed NMEA APP BT autoconnection mode
2017.09.13  - 0.8.13	- 002	- VP    - 16547		- SendWithoutTS paramters has options like FMA (AfterPositionFix, Always, AfterTimeSync)
2017.09.12  - 0.8.13	- 001	- AA    - 16631		- Mantis bugfix by Boris.H
										- 16040		- Ble easy config DEV done from configurator side (not done from Fw side yet).
2017.09.08  - 0.8.11	- 001	- AA    - 16532		- Mantis bugfix by Boris.H
										- 16564		- Mantis bugfix by Boris.H
2017.09.05  - 0.8.09	- 001	- AA    - 16532		- Fixed configuration error -> which caused "failed to save configuration" messages @ configurator. V2
2017.09.04  - 0.8.07	- 002	- AA    - 16453		- Fixed configuration error -> which caused "failed to save configuration" messages @ configurator.
										- 16532		- Same as 16453.
2017.09.01  - 0.8.07	- 001	- KB    - 16447		- Updated .exe to 8.7 - fixed switch control
2017.09.01  - 0.8.06	- 002	- KB    - 16439		- Changed default FOTA WEB Domain.
2017.09.01  - 0.8.06	- 001	- KB    - 16386		- Updated .exe to 8.6 - config loading improvements. Mantis: 16386, 16443, 16453, 16467.
													- Fixed bug when saving params to device with coma decimal sign
2017.09.01  - 0.8.05	- 001	- KB    - 16434		- Updated .exe to 8.5 - various fixes + new BT lib. Mantis 14748
2017.08.24  - 0.8.04	- 001	- RV    - 			- Add FM30YX HWs CFGs.
2017.08.24  - 0.8.03	- 001	- KB    - 			- All configuartion description reworked for diff writing. Removed many old anused configs.
---------------------------------------------------------------------------------
2017.08.22  - 0.7.15	- 003	- DA    - 			- TMT250: Removed not needed IOs from IO list. Fixed man down SMS event IDs when merged with master branch from 03.01.03.
2017.08.16  - 0.7.15	- 003	- RV    - 15843		- Added new BT autoconnection mode + User ID IO.
2017.08.16  - 0.7.15	- 002	- MA    - 			- SIM2 Operator list tooltip updated.
2017.08.14  - 0.7.15	- 001	- MA    - 			- Updated .exe to 0.7.15.
2017.08.10  - 0.7.11	- 003	- DA    - 16216		- TMT250: Added ManDown settings.
2017.08.08  - 0.7.11	- 002	- KB    - 			- Fixed FMB125HW config autodetection
2017.08.08  - 0.7.11	- 001	- KB    - 			- Updated exe to 7.11 (config parameters + mantis 16054)
2017.08.08  - 0.7.09	- 002	- MA    - 			- Added FMB125 HW without battery support
2017.08.04  - 0.7.09	- 001	- MA    - 15935		- Localization file updated.
2017.08.02  - 0.7.04	- 002	- DA    - 16145		- TMT250: removed old configuretion file, in new configuration file (from_03.01.00) removed OBDII IOs and reformated text.
2017.07.31  - 0.7.04	- 001	- MG    - 15957		- Added GBS Bulgaria Spec config (SpecId = 101)
2017.07.28  - 0.7.03	- 002	- VP    - 16107		- SIM Roaming Op List name updated to "SIM2 Roaming Operator List".
2017.07.28  - 0.7.03	- 001	- KB    - 15826		- Added BT control via configurator.
										- 16025		- Added Spec FW Management
										- 16054		- Fixed SIM2 PIN code input
										- 16062		- Added new configs version. Added iButton Notify config for FMB1xx HW
---------------------------------------------------------------------------------
2017.07.26  - 0.6.59	- 001	- KB    - 			- Updated exe to 59
2017.07.21  - 0.6.57	- 001	- KB    - 15243		- Updated exe. LLS IDs selecting fix.
2017.07.21  - 0.6.56	- 006	- KB    - 15959		- Fixed FMB122 and FMB110 config names
2017.07.20  - 0.6.56	- 005	- VP    - 15844		- FMB001,FMB010 - DIN1 Call Trigger option removed.
2017.07.19  - 0.6.56	- 004	- SP    - 15234		- Added FOTA WEB functionality parameters.
2017.07.19  - 0.6.56	- 003	- LL    - 			- Added TMT250 prototype hw support
2017.07.18  - 0.6.56	- 002	- VP    - 15549		- Deep Sleep IO renamed to Sleep Mode.
2017.07.18  - 0.6.56	- 001	- KB    - 15937		- Updated .exe to 0.6.56.
2017.07.18  - 0.6.55	- 001	- KB    - 15976		- Updated .exe to 0.6.55. Added config for FMB1xx dual sim. Changed Idling stop/start defaults
								- KB    - 15862		- FMB.Configurator exe moved to %APPDATA% for avoiding admin rights
2017.07.12  - 0.6.54	- 002	- MA    - 15881		- Updated .exe to 0.6.54 and added missing tooltips.
2017.07.12  - 0.6.52	- 002	- AS    - 15881		- Adjusted battery voltage I/O element max value for FMB962 device.
2017.07.11  - 0.6.52	- 001	- RV    - 15877		- Updated exe to 0.6.52
2017.07.11  - 0.6.51	- 001	- RV    - 15737		- Updated exe to 0.6.51. Updated localization. Fixed GNSS status IO element high level maximum in latest configurations
2017.07.11  - 0.6.47	- 002	- KB    - 15732		- Fixed Config Title for FMB962 HW
2017.07.11  - 0.6.47	- 001	- KB    - 15740		- Updated exe to  0.6.47. Fixed selectable by bitmask boxes
2017.07.11  - 0.6.46	- 001	- KB    - 15886		- Updated exe to  0.6.46. Updated firmware validation logic
2017.07.05  - 0.6.43	- 001	- KB    - 15852		- Updated exe to  0.6.43. Fixed BT radio default value, autogeofence min radius. Mantis 15852, 15840
2017.06.29  - 0.6.39	- 001	- KB    - 15740		- Updated exe to  0.6.39. New configs for 01.00.32 (Ign rework, 200 gsm numbers mantis 15778)
2017.06.26  - 0.6.36	- 001	- AA    - 15737		- Updated exe to  0.6.33. Mantis: 15737, 15735, 15732, 15762.
2017.06.26  - 0.6.33	- 001	- AA    - 15637		- Updated exe to  0.6.33.
2017.06.23  - 0.6.32	- 001	- AA    - 15743		- Updated exe to  0.6.32.
2017.06.23  - 0.6.29	- 001	- KB    - 15733		- Updated exe to  0.6.31. Mantis 15733, 15584
2017.06.23  - 0.6.27	- 001	- KB    - 15644		- Updated exe (LLS req fix).
										- 15736		- Changed config UI layouts.
										- 15669		- Added config files for FMB0xx, FMB9xx 03.00.00.
2017.06.22  - 0.6.26	- 003	- VP    - 15125		- Towing min values fixed for configurations 01.00.31.
2017.06.16  - 0.6.26	- 002	- MG    - 14949		- Operator Black List functionality added.
2017.06.16  - 0.6.26	- 001	- KB    - 			- Updated to 0.6.26: Added firmware cancel check
2017.06.15  - 0.6.25	- 001	- KB    - 15549		- Deep Sleep IO renamed to Sleep Mode
2017.06.15  - 0.6.25	- 001	- RV    - 15385		- Configurator *.exe updated to 0.6.25 + added keywords parameter ID to CFGs + updated LLS configuration.
2017.06.13  - 0.6.17	- 004	- VP    - 		 	- SN Mov Source and Ignition Source Defaults fixed.
2017.06.13  - 0.6.17	- 004	- KB    - 		 	- Added Odometer configuration for FMB1xx. Removed ":" from labels. Changed menu order.
										- 			- Added abstract.txt releasing. Changed packed .exe overwrite mode (do not skip blocked files)
2017.06.12  - 0.6.17	- 003	- AA    - 15587 	- +Resources folder for release.
2017.06.12  - 0.6.17	- 002	- VP    - 15558 	- DS info and tooltips updated.
2017.06.09  - 0.6.17	- 001	- AA    - 15518 	- Configurator exe updated to 0.6.17.
								- VP	- 15558		- Fixed Static Navigation Tooltip @ localization
								- VP	- 15551		- Removed spycall functionality configuration @ 01.00.30.Rev.XX configurations
2017.06.08  - 0.6.16	- 001	- VP    - 		 	- SpyCall removed from 01.00.31.
2017.06.08  - 0.6.16	- 001	- VP    - 15518 	- Configurator exe updated to 0.6.16.
2017.06.08  - 0.6.13	- 003	- VP    - 		 	- New Configurations from_01.00.31 Created
2017.06.07  - 0.6.13	- 002	- KB    - 		 	- Synced with submodule. Updated on_stop and moving group boxes
2017.06.06  - 0.6.13	- 001	- VP    - 		 	- Configurator exe updated to 0.6.13.
2017.06.06  - 0.6.10	- 003	- VP    - 15395	 	- Static Navigation Movement Source Added. New Config for 2.00.01.
2017.06.05  - 0.6.10	- 003	- KB    - 		 	- Missing tool tips added. Auto Answer (HF) tool tip fixed.
2017.06.05  - 0.6.10	- 002	- VP    - 15490	 	- Backup tooltips added.
2017.06.05  - 0.6.10	- 002	- VP    - 15390 	- auto answer (HF) tooltip changed.
2017.06.05  - 0.6.10	- 002	- VP    - 15166 	- Configuration for FMB125 updated.
2017.06.05  - 0.6.10	- 001	- AA    - 15488 	- Configurator exe updated to 0.6.10.
2017.06.01  - 0.6.09	- 001	- AA    - 15456 	- Configurator exe updated to 0.6.09.
													- Added param validations to configurations.
													- All possible validations: Mac, Pin4, Pin8, Pin4Optional, Pin8Optional, IButton, Phone, Operator, Pin4To8, Pin4To8Optional.
2017.05.31  - 0.6.05	- 001	- AA    - 15456 	- Configurator exe updated to 0.6.05.
2017.05.31  - 0.6.04	- 001	- VP    - 15398 	- Configurator exe updated to 0.6.04.
2017.05.29  - 0.6.03	- 002	- VP    -       	- Defaults Updated (sendperiod, sleeptmo, IO parameters) Config 2.00.01.
2017.05.26  - 0.6.03	- 001	- VP    -       	- Configurator exe updated to 0.6.03.
2017.05.26  - 0.6.02	- 002	- VP    - 15334 	- Defaults changed for old 01.98.01 Configuration.
2017.05.26  - 0.6.02	- 001	- VP    -       	- Configurator exe updated to 0.6.02.
---------------------------------------------------------------------------------
2017.05.26  - 0.5.22	- 004	- VP    - 15334 	- Ignition collection name changed for old versions.
2017.05.25  - 0.5.22	- 003	- VP    - 15334 	- Configurations for FMB.Ver.01.00.30+ .
2017.05.24  - 0.5.22	- 002	- RV    - 		 	- Updated FMB125 configuration file.
2017.05.23  - 0.5.22	- 002	- KB    - 		 	- Added FMB125 configuration file.
2017.05.23  - 0.5.22	- 002	- SP    - 13405 	- Manual Geofencing config, Image resize to reduce overall size.
2017.05.23  - 0.5.22	- 002	- VP    - 15279 	- GPS Op/ GNSS. Default Monitoring.
2017.05.22  - 0.5.22	- 002	- MA    - 12125 	- Towing detection sensitivity range increased.
2017.05.22  - 0.5.22	- 002	- VP    - 15223		- Record save MinPeriod and SendPeriod, max value fixed 2592000.
2017.05.19  - 0.5.22	- 002	- VP    - 14090		- Added configuration files for version 1.6.0 (Backup Server settings).
2017.05.18  - 0.5.22	- 001	- SP    - 			- Configurator exe updated to 0.5.22, Added localization for immobilizer, Missing ShapeType Collection.
2017.05.16  - 0.5.15	- 001	- SP    - 			- Configurator exe updated to 0.5.17, Adjusted config for spec geozones.
2017.05.16  - 0.5.15	- 001	- SP    - 			- Configurator exe updated to 0.5.15, Added config for spec version with 5 geozones.
2017.05.12  - 0.5.12	- 002	- VP    - 			- Parameter Open Link Timeout min:30; def:30.
2017.05.10  - 0.5.12	- 001	- AA    - 			- Configurator exe updated to 0.5.12 version.
2017.05.10  - 0.5.10	- 001	- AA    - 			- Configurator exe updated to 0.5.10 version.
2017.05.09  - 0.5.9.0	- 001	- AA    - 			- Configurator exe updated to 0.5.9.0 version.
													- en-US.xml localization file updated.
													- Added geofence params collections for 01.01.00 configs.
													- Sorted iButtonList params for FMB1XX HW configs.
2017.05.08  - 0.5.6.0	- 002	- AS    - 			- Fixed "Ignition Source" parameter configuration.
2017.05.08  - 0.5.6.0	- 001	- AA    - 			- Configurator exe updated to 0.5.6.0 version.
2017.05.05  - 0.5.5.0	- 003	- KB    - 15077		- AIN 10/30V switch default value changed to 30V
2017.05.03  - 0.5.5.0	- 002	- RV    - 15001		- Added Authorized/Predefined numbers validation
2017.05.03  - 0.5.5.0	- 001	- RV    - 			- Configurator exe updated to 0.5.5.0
										- 14968		- Updated localization with tooltips
2017.05.02  - 0.5.3.0	- 001	- RV    - 			- Configurator exe updated to 0.5.3.0
													- Added FmType to old CFGs
										- 14812		- Changed ibutton configuration
										- 13898		- Updated localization
													- Updated DS and EcoScore IOs max High lvl values
													- Returned missing CFGs
													- Added missing EcoScore configuration
2017.04.28  - 0.5.1.0	- 002	- RV    - 			- Added jamming tmo parameter for FMB1
2017.04.25  - 0.5.1.0	- 001	- RV    - 			- Added FMB1 support. IgnSrc + AIN value Range + OutCallAction + LVCAN IO units, min/max values + new params + new Mov/Ign source config
---------------------------------------------------------------------------------
2017.04.27  - 0.4.26.1	- 004	- VP    - 13116		- EcoScore IO added/ EcoScore allowed events moved to trip.
2017.04.24  - 0.4.26.1	- 003	- VP    - 14955		- "Operator list" renamed to "Roaming Operator List".
2017.04.19  - 0.4.26.1	- 002	- VP    - 14869		- Added new parameter Jamming Timeout. ID:11305.
2017.04.12  - 0.4.26.1	- 001	- AA    - 14377		- Configurator exe updated to 0.4.26.1 version.
													  Created new configs for 01.00.25+. Min configurator version changed to 0.4.26.0 (BtAuthMacList validation changes)
													  Created new configs for FMB962/FMB964
2017.04.12  - 0.4.26.0	- 001	- AA    - 14734		- Configurator exe updated to 0.4.26.0 version.
2017.04.04  - 0.4.24.3	- 002	- KB    - 			- Added Movement Start/Stop delay parameters
2017.04.04  - 0.4.24.3	- 001	- AA    - 			- Configurator exe updated to 0.4.24.3 version.
2017.03.31  - 0.4.24.2	- 001	- AA    - 			- Configurator exe updated to 0.4.24.2 version.
2017.03.31  - 0.4.24.1	- 001	- AA    - 			- Configurator exe updated to 0.4.24.1 version.
2017.03.31  - 0.4.24.0	- 002	- AA    - 			- Removed not needed xml files. Returned proper en-US.xml file.
2017.03.31  - 0.4.24.0	- 001	- KB    - 14665		- Removed Spy Call from configs
2017.03.31  - 0.4.23.0	- 004	- KB    - 13801		- Added Online Sleep parameter
2017.03.29  - 0.4.23.0	- 004	- KB    - 14608		- Added new IOs: ICCID and SD status
2017.03.28  - 0.4.23.0	- 003	- SP    - 14367		- Divided TimeZones by 30min, from UTC-12 to UTC+14.
2017.03.27  - 0.4.23.0	- 002	- AA    - 			- Added FmType to new configs
2017.03.27  - 0.4.23.0	- 001	- AA    - 			- Configurator exe updated to 0.4.23.0 version.
2017.03.20  - 0.4.22.0	- 002	- AA    - 			- Updated en-US.xml file with A. Krupovic changes
2017.03.20  - 0.4.22.0	- 001	- AA    - 			- Configurator exe updated to 0.4.22.0 version.
													  MinimumConfiguratorVersion -> 0.4.22.0 (because of addition: TextMinLength, Optional)
2017.03.16  - 0.4.21.3	- 001	- AA    - 			- Configurator exe updated to 0.4.21.3 version.
													- Par 802, 806 types changed to Pin (numeric only + length validation).
2017.03.15  - 0.4.20.5	- 001	- AA    - 			- Configurator exe updated to 0.4.20.5 version.
													  Towing -> Threshold -> units -> changed from "G" to "g" (basically the same, just accleration representation should be g small)
2017.03.13  - 0.4.20.3	- 001	- AA    - 			- Configurator exe updated to 0.4.20.3 version.
													  Configurations version changed to: 1.1.1. This applies for changes in 01.00.22.Rev.05 (forgot to properly change cfg version @ FW)
2017.03.13  - 0.4.20.2	- 001	- AA    - 			- Configurator exe updated to 0.4.20.2 version.
2017.03.13  - 0.4.20.1	- 001	- AA    - 			- Configurator exe updated to 0.4.20.1 version.
2017.03.13  - 0.4.19.7	- 002	- AA    - 14370		- Changed max acceleration,corner,braking parameters to double. Min 0.5, max 10.0. Defaults: 2.2, 2.5, 2.1. Units: m/s^2.
													- This change applied since FW version 01.00.22.Rev.05++
								- VP	- 			- Towing->Threshold units changed from "mg" to "G".
2017.03.10  - 0.4.19.7	- 001	- AA    - 			- V.Meskauskis added MAC address validation.
---------------------------------------------------------------------------------
  		LEGEND:
---------------------------------------------------------------------------------
  * "DATE"	- Date of Build
  * "VER"	- Version (*.exe)
  * "C"		- Configuration version
  * "A"		- Author
  * "CHANGES" - Brief Description of Changes made within scope of Build
---------------------------------------------------------------------------------