Line 19: |
Line 19: |
| Start Speed – GNSS speed has to be greater than the specified Start Speed in order to detect Trip Start. <br> | | Start Speed – GNSS speed has to be greater than the specified Start Speed in order to detect Trip Start. <br> |
| Ignition Off Timeout – timeout to wait if ignition was off, to detect Trip stop. <br> | | Ignition Off Timeout – timeout to wait if ignition was off, to detect Trip stop. <br> |
− | Distance Mode – Between records, Continuous trip or Continuous can be chosen. For this feature I/O Odometer must be enabled (see Figure 30). <br> | + | Distance Mode – Between records, Continuous trip or Continuous can be chosen. For this feature I/O Odometer must be enabled (see Figure above). <br> |
| If I/O Odometer is enabled and Distance Mode variable is set to “Continuous trip”, '''Trip distance''' is going to be counted continuously '''(from Trip start to Trip stop)'''. This value is written to I/O Odometer value field. When Trip is over and next Trip begins, Odometer value is reset to zero. When the next trip starts counting continuously starts from the beginning again. <br> | | If I/O Odometer is enabled and Distance Mode variable is set to “Continuous trip”, '''Trip distance''' is going to be counted continuously '''(from Trip start to Trip stop)'''. This value is written to I/O Odometer value field. When Trip is over and next Trip begins, Odometer value is reset to zero. When the next trip starts counting continuously starts from the beginning again. <br> |
| If I/O Odometer is enabled and Distance Mode variable is set “Between records”, then the distance is going to be counted only between every record made. This value is written to I/O Odometer value field and reset to zero every new record until Trip stops. <br> | | If I/O Odometer is enabled and Distance Mode variable is set “Between records”, then the distance is going to be counted only between every record made. This value is written to I/O Odometer value field and reset to zero every new record until Trip stops. <br> |
− | If I/O Odometer is enabled and Distance Mode variable is set “Continuous”, '''Trip distance'' is going to be counted continuously (Starting from trip start, trip distance is saved to flash memory). <br> | + | If I/O Odometer is enabled and Distance Mode variable is set “Continuous”, '''Trip distance'' is going to be counted continuously (Starting from trip start, trip distance is saved to flash memory, see Figure below). <br> |
| Continuous Odometer Value – gives ability to set starting value of the “Continuous” trip. <br> | | Continuous Odometer Value – gives ability to set starting value of the “Continuous” trip. <br> |
| Remember iButton ID – devices remembers connected iButtons id(While trip is detected) and sends it to server along with periodical records. | | Remember iButton ID – devices remembers connected iButtons id(While trip is detected) and sends it to server along with periodical records. |