Changes

1,291 bytes removed ,  12:08, 4 September 2020
m
Replaced content with "{{Template:FMX640 and J1708 |model=FMC640 |FMB640CFG = }} Category:FMC640 Manual"
Line 1: Line 1: −
SAE J1708 is a standard used for serial communications between ECUs on a heavy duty. The hardware utilized are RS-485 transceivers wired for open collector operation through the use of a pullup and pulldown of the separate data lines.
+
{{Template:FMX640 and J1708
 
+
|model=FMC640
With FMC640, J1708 functionality is used to read vehicle's Fuel Level and Fuel consumption.
+
|FMB640CFG = }}
 
  −
Because J1708 is not a CAN BUS protocol, FMC640 CAN1 and CAN2 lines cannot be used to read J1708 information. FMC640 has a special J1708 Port, which utilizes RJ9 4P4C connector.
  −
 
  −
[[image:J1708.png]]
  −
[[image:J1708_pinout.png]] <br>
  −
 
  −
==Software Configuration of FMC640 with J1708==
  −
 
  −
Firmware version: 00.00.11 or above
  −
Configurator version: 0.13.35.29297 or above
  −
 
  −
J1708 configuration is done in FMS IO Tab.
  −
 
  −
[[image:J1708_config.gif]]
  −
 
  −
When J1708 is enabled as Fuel Level source, Fuel related data will be taken from J1708 line, FMS Fuel data will be ignored.
  −
 
  −
==Connection with Vehicle port==
  −
 
  −
J1708 connector is not supported by all vehicles. Only VOLVO, RENAULT and American truck manufacturers implement J1708 connector.
  −
 
  −
[[image:J1708_pinout1.png]]
  −
 
  −
Trucks utilizes Deutsch 9-PIN connector, which is used to connect FMC640 to J1708.
  −
 
  −
[[image:Deutsch_j1708.png]]
  −
 
  −
{|
  −
| [[File:Alert.png|left|link=|50px]] || <b>NOTE: Most of the Volvo trucks need an J1708 connection to be able to receive fuel level data</b>
  −
|}
   
[[Category:FMC640 Manual]]
 