Changes

500 bytes added ,  15:41, 4 December 2020
Line 41: Line 41:     
After 4  seconds (1000 ms per Block ID) all values will be captured again. Device checks last saved value of Tell Tale IO elements and if it is changed – values are updated.
 
After 4  seconds (1000 ms per Block ID) all values will be captured again. Device checks last saved value of Tell Tale IO elements and if it is changed – values are updated.
 +
 +
Received data:
 +
 +
Block ID = 0| 0xFF8F88FFBFFFFFF0
 +
 +
1 Byte FF | Binary 1111 1111 | Status 1     
 +
2 Byte 8F | Binary 1000 1111 | Status 2;3
 +
3 Byte 88 | Binary 1000 1000 | Status 4;5
 +
4 Byte FF | Binary 1111 1111 | Status 6;7
 +
5 Byte BF | Binary 1011 1111 | Status 8;9
 +
6 Byte FF | Binary 1111 1111 | Status 10;11
 +
7 Byte FF | Binary 1111 1111 | Status 12;13
 +
8 Byte F0 | Binary 1111 0000 | Status 14;15
 +
 +
 +
 +
 +
Block ID = 1| 0xFFFFFFFFFFFF8FF1
 +
Block ID = 2| 0xFFFF8FFFFFF8FFF2
 +
Block ID = 3| 0xFFFFFFFFFFFFFFF3
    
=='''Quick links'''==
 
=='''Quick links'''==