Changes

Line 57: Line 57:  
| Spraying water || Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield.   
 
| Spraying water || Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield.   
 
Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum. ||  For a Spray Nozzle:
 
Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum. ||  For a Spray Nozzle:
Test duration: 1 minute per square meter for at least 5&nbsp;minutes<ref>Table 8, IEC 60529, Edition 2.2, 2013</ref><br />
+
Test duration: 1 minute per square meter for at least 5&nbsp;minutes<br />
 
Water volume: 10&nbsp;litres per minute<br />
 
Water volume: 10&nbsp;litres per minute<br />
 
Pressure: 50–150&nbsp;kPa
 
Pressure: 50–150&nbsp;kPa
   
For an oscillating tube:
 
For an oscillating tube:
   
Test duration: 10 minutes
 
Test duration: 10 minutes
   
Water Volume: 0.07 l/min per hole
 
Water Volume: 0.07 l/min per hole
 
|}
 
|}
0