Line 13: |
Line 13: |
| platform which provides extended functionality. Configure, scan, and update anytime anywhere with a dedicated | | platform which provides extended functionality. Configure, scan, and update anytime anywhere with a dedicated |
| Teltonika mobile app. | | Teltonika mobile app. |
− |
| |
− | ==Configurating beacon device==
| |
− | Devices work constantly and are ready to perform out of the box. Default basic Sensor settings are set to:
| |
− | <br>• Transmitting at 2 dBm power.
| |
− | <br>• Data advertising at 3 second intervals.
| |
− | <br>• Eddystone protocol
| |
− | <br>
| |
− | <br> If you would like to change these settings you will need to:
| |
− | <br>1) Download and install EYE APP - Teltonika application to change sensor settings.
| |
− | <br>[[File:QR.jpg]]
| |
− | <br>
| |
− |
| |
− | '''With the application you will be able to scan for visible Teltonika EYE devices, check their statuses or connect for configuration or firmware update.'''
| |
− | [[File:Devices in view.jpg|450px|left]]
| |
− | '''Devices in view''': In this window you will see all visible devices. You have options to see devices in Short list (1) or in default list. When looking at devices in default list you will be able to open Detailed view (2) of devices and check transmitted data statuses. Additionaly if you are looking for specific devices you will be able to use Search (3) function to filter search options. When in this window select a device of your choice to connect and after passing pin code you will go to device overview window.
| |
− | <br><br></br><br></br><br></br><br></br><br></br><br></br><br></br><br></br>
| |
− | [[File:Overview window.jpg|450px|left]]
| |
− | '''Overview window''': In overview window you can see device details (1), check firmware version and update if available (2), go to device configuration settings. If you select to Configure (3) device new window will open with Basic and Advanced settings.
| |
− | <br><br></br><br></br><br></br><br></br><br></br><br></br><br></br><br></br><br>
| |
− | [[File:Configure window.jpg|450px|left]]
| |
− | '''Configure window''': In this window you can check and change device configuration settings. In main tab Basic Settings (1) you can change main settings. Change Device name (2.1), Power signal strength (2.2), Advertising interval (2.3) and Packet (2.4) transmition type. For more settings go to Advanced settings (3) tab to enable various events.
| |
− | <br><br></br><br></br><br></br><br></br><br></br>
| |
− |
| |
− | ==Protocol overwiev==
| |
− |
| |
− | ===Beacon advertising===
| |
− | <br>
| |
− | [[File:Beacon advertising.png|center]]
| |
− |
| |
| ==Product information== | | ==Product information== |
| {| class="wikitable" | | {| class="wikitable" |
Line 162: |
Line 133: |
| <br> | | <br> |
| [[File:Mounting recomendations 1.jpg]] | | [[File:Mounting recomendations 1.jpg]] |
| + | |
| + | ==Configurating beacon device== |
| + | Devices work constantly and are ready to perform out of the box. Default basic Sensor settings are set to: |
| + | <br>• Transmitting at 2 dBm power. |
| + | <br>• Data advertising at 3 second intervals. |
| + | <br>• Eddystone protocol |
| + | <br> |
| + | <br> If you would like to change these settings you will need to: |
| + | <br>1) Download and install EYE APP - Teltonika application to change sensor settings. |
| + | <br>[[File:QR.jpg]] |
| + | <br> |
| + | |
| + | '''With the application you will be able to scan for visible Teltonika EYE devices, check their statuses or connect for configuration or firmware update.''' |
| + | <br> |
| + | {| |
| + | |-align="center" |
| + | | |
| + | |[[File:Detailed list - collapsed(2).jpg|border|360x640px|none]] |
| + | | |
| + | |[[File:Overview - without update (beacon)(2).png|border|360x640px|none]] |
| + | | |
| + | |[[File:Basic settings(2).png|right|border|360x640px|none]] |
| + | | |
| + | |-align="center" valign="top" |
| + | |} |
| + | <br> |
| + | [[File:Frame 115.png|bottom|frameless|upright=0.2|link=|alt=]] '''Devices in view''': In this window you will see all visible devices. You have options to see devices in Short list [[File:Shortlist.jpg|30px]] or in default list. When looking at devices in default list you will be able to open Detailed view [[File:Detailed.jpg]] of devices and check transmitted data statuses. Additionaly if you are looking for specific devices you will be able to use Search [[File:Search button eye app.jpg|30px]] function to filter search options. When in this window select a device of your choice to connect and after passing pin code you will go to device overview window. |
| + | <br> |
| + | <br> |
| + | [[File:Group 125.png|baseline|frameless|upright=0.2|link=|alt=]]'''Overview window''': In overview window you can see device details, check firmware version and update if available , go to device configuration settings. If you select to Configure device new window will open with Basic and Advanced settings. |
| + | <br> |
| + | <br> |
| + | [[File:Group 116.png|sub|frameless|upright=0.2|link=|alt=]]'''Configure window''': In this window you can check and change device configuration settings. In main tab Basic Settings you can change main settings. Change Device name, Power signal strength, Advertising interval and Packet transmition type. For more settings go to Advanced settings tab to enable various events. |
| + | |
| + | ==Protocol overwiev== |
| + | |
| + | ===Beacon advertising=== |
| + | <br> |
| + | [[File:Beacon advertising.png|center]] |
| | | |
| ==Safety information== | | ==Safety information== |