Changes

336 bytes added ,  10:54, 2 September 2021
m
no edit summary
Line 1: Line 1: −
{| class="wikitable" style="border-style: solid; border-width: 0px"
+
{| class="nd-othertables_2" style="border-style: solid; border-width: 0px"
 
|+
 
|+
 
|-
 
|-
| style="text-align: left; background: #F6F6FB;" |[[Image:Bw_nb.png|50px]]
+
| style="text-align: left;" |[[Image:Bw_nb.png|50px]]
| style="text-align: left; background: #F6F6FB;" |Please order accessories separately as they are not included into device package.
+
| style="text-align: left;" |Please order accessories separately as they are not included into device package.
 
|-
 
|-
 
|}
 
|}
   −
 
+
{| class="nd-othertables_2"
{| class="wikitable"
   
|+
 
|+
! style="width: 300px; background: black; color: white;" |Accessory and its description
+
! style="width: 300px; color: white;" |Accessory and its description
! style="width: 500px; background: black; color: white;" |Accessory connection schematic
+
! style="width: 500px; color: white;" |Accessory connection schematic
 
|-
 
|-
    
! style="text-align: left; vertical-align: top;" |Fuel tank sensors
 
! style="text-align: left; vertical-align: top;" |Fuel tank sensors
! style="text-align: left; vertical-align: top;" |Fuel sensor connection to {{{model|FMB140}}}
+
! style="text-align: center; vertical-align: top;" |Fuel sensor connection to {{{model|FMB1YX}}}
 
|-
 
|-
| style="text-align: left; vertical-align: top;" |A fuel tank level sensor which indicates the approximate fuel level on the driver's indicator panel exists in most cars. If the sensor returns analogue signal proportional to fuel level it can be connected to {{{model|FMB140}}} Analog input. After connection to the tank fuel level sensor a calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage values resulting from the volume of fuel in tank.
+
| style="text-align: left; vertical-align: top;" |A fuel tank level sensor which indicates the approximate fuel level on the driver's indicator panel exists in most cars. If the sensor returns analogue signal proportional to fuel level it can be connected to {{{model|FMB1YX}}} Analog input. After connection to the tank fuel level sensor a calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage values resulting from the volume of fuel in tank.
 
| style="text-align: left; vertical-align: top;" |[[Image:Sch_fmb1yx_lls.png|250px|center]]
 
| style="text-align: left; vertical-align: top;" |[[Image:Sch_fmb1yx_lls.png|250px|center]]
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" |Alarm buttons, door sensors etc.
 
! style="text-align: left; vertical-align: top;" |Alarm buttons, door sensors etc.
! style="text-align: left; vertical-align: top;" |Panic button connection to {{{model|FMB140}}}
+
! style="text-align: center; vertical-align: top;" |Panic button connection to {{{model|FMB1YX}}}
 
|-
 
|-
| style="text-align: left; vertical-align: top;" |Alarm buttons, door sensors, ignition, etc. have two output states: high or low. {{{model|FMB140}}} Digital inputs are used to detect these states.
+
| style="text-align: left; vertical-align: top;" |Alarm buttons, door sensors, ignition, etc. have two output states: high or low. {{{model|FMB1YX}}} Digital inputs are used to detect these states.
 
| style="text-align: left; vertical-align: top;" |[[Image:Sch_fmb1yx_panic.png|400px|center]]
 
| style="text-align: left; vertical-align: top;" |[[Image:Sch_fmb1yx_panic.png|400px|center]]
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" |Relays
 
! style="text-align: left; vertical-align: top;" |Relays
! style="text-align: left; vertical-align: top;" |Inverting relay connection to {{{model|FMB140}}}
+
! style="text-align: center; vertical-align: top;" |Inverting relay connection to {{{model|FMB1YX}}}
 
|-
 
|-
 
| style="text-align: left; vertical-align: top;" |In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive.
 
| style="text-align: left; vertical-align: top;" |In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive.
Line 33: Line 32:  
|-
 
|-
 
! style="text-align: left; vertical-align: top;" |Immobilizer relay
 
! style="text-align: left; vertical-align: top;" |Immobilizer relay
! style="text-align: left; vertical-align: top;" |Immobilizer relay connection to {{{model|FMB140}}} output
+
! style="text-align: center; vertical-align: top;" |Immobilizer relay connection to {{{model|FMB1YX}}} output
 
|-
 
|-
| style="text-align: left; vertical-align: top;" |When connected as shown on the right hand side, {{{model|FMB140}}} disables engine starter when output is ON.
+
| style="text-align: left; vertical-align: top;" |When connected as shown on the right hand side, {{{model|FMB1YX}}} disables engine starter when output is ON.
 
| style="text-align: left; vertical-align: top;" |[[Image:Sch_fmb1yx_imb_relay.png|400px|center]]
 
| style="text-align: left; vertical-align: top;" |[[Image:Sch_fmb1yx_imb_relay.png|400px|center]]
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" |Automotive relay
 
! style="text-align: left; vertical-align: top;" |Automotive relay
! style="text-align: left; vertical-align: top;" |Automotive relay pinout
+
! style="text-align: center; vertical-align: top;" |Automotive relay pinout
 
|-
 
|-
 
|-
 
|-
Line 46: Line 45:  
|-
 
|-
 
! style="text-align: left; vertical-align: top;" |{{{oneWire|1-Wire devices}}}
 
! style="text-align: left; vertical-align: top;" |{{{oneWire|1-Wire devices}}}
! style="text-align: left; vertical-align: top;" |{{{oneWire|I-Button DS1990A connection to {{{model|FMB140}}} }}}
+
! style="text-align: center; vertical-align: top;" |{{{oneWire|Digital thermometer DS1820 and TTJ100 connection to {{{model|FMB1YX}}} }}}
 
|-
 
|-
| rowspan="1" style="text-align: left; vertical-align: top;" |{{{oneWire|One of the implemented features on {{{model|FMB140}}} is 1-Wire® data protocol, which enables the use of I-Button DS1990A and devices such as thermometer (DS1820, DS18S20 and DS18B20) }}}
+
| rowspan="5" style="text-align: left; vertical-align: top;" |{{{oneWire|One of the implemented features on {{{model|FMB1YX}}} is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A. }}}
 
      +
Accessories that use 1-Wire Power and 1-Wire Data connections are not compatible with the FMB140, because it lacks a 1-Wire Power pin.
 +
| style="text-align: left; vertical-align: top;" |{{{oneWire| {{{pic_ds1820|[[Image:Sch_fmb120_ds1820.png|400px|center]]}}} }}}
 +
|-
 +
! style="text-align: center; vertical-align: top;" |{{{oneWire| I-Button DS1990A connection to {{{model|FMB1YX}}} }}}
 +
|-
 
| style="text-align: left; vertical-align: top;" |{{{oneWire| [[Image:Sch_fmb1yx_ibutton.png|400px|center]] }}}
 
| style="text-align: left; vertical-align: top;" |{{{oneWire| [[Image:Sch_fmb1yx_ibutton.png|400px|center]] }}}
{{{oneWire| [[Image:Asdv.png|400px|center]] }}}
   
|-
 
|-
 
|}
 
|}
 +
 +