Changes

463 bytes added ,  14:48, 24 September 2021
no edit summary
Line 4: Line 4:  
==Supported Thermographs==
 
==Supported Thermographs==
   −
DataCold600*, Transcan2**, Touchprint**.
+
FMX640 can be connected to DataCold600, Transcan2, TouchPrint thermographs.
   −
<nowiki>*</nowiki>Used with Carrier freezers.
+
Refer to the table bellow to see which freezers use which thermograph:
 
+
{| class="wikitable"
<nowiki>**</nowiki>Used with Thermoking freezers.
+
|+
 +
!
 +
|Thermograph Type
 +
!
 +
!
 +
|-
 +
|Freezer Type
 +
|DataCold600
 +
|Transcan2
 +
|TouchPrint
 +
|-
 +
|Carrier
 +
| +
 +
| -
 +
| -
 +
|-
 +
|ThermoKing
 +
| -
 +
| +
 +
| +
 +
|}
    
== RS-232 Interface ==
 
== RS-232 Interface ==
Line 17: Line 37:  
==Installation guide==
 
==Installation guide==
   −
=== '''Thermoking'''===
+
=== '''Touchprint'''===
 
[[File:Thermoking.png|center|frameless|665x665px]]
 
[[File:Thermoking.png|center|frameless|665x665px]]
   Line 57: Line 77:  
==Configuration==
 
==Configuration==
   −
Make sure the FMx640 device is configured to receive data from “Transcan2 Reefer”, "Touchprint Reefer" or "DataCold Reefer". To do this, enter the configurator window, select the RS232 \ RS485 section displayed in the screenshots below, and configure accordingly (COM1 Settings, Mode “Transcan2 Reefer”, "Touchprint Reefer" or "DataCold Reefer", Baudrate: Default)
+
Make sure the FMx640 device is configured to receive data from “Transcan2 Reefer”, "Touchprint Reefer" or "DataCold Reefer". To do this, enter the configurator window, select the RS232 \ RS485 section displayed in the screenshots below, and configure accordingly (COM1/COM2 Settings, Mode “Transcan2 Reefer”, "Touchprint Reefer" or "DataCold Reefer", Baudrate: Default)
    
[[File:Transcan2_Reefer_2021_08_12.png|alt=|frameless|746x746px]][[File:Touchprint_Reefer_2021_08_12.png|alt=|frameless|746x746px]]
 
[[File:Transcan2_Reefer_2021_08_12.png|alt=|frameless|746x746px]][[File:Touchprint_Reefer_2021_08_12.png|alt=|frameless|746x746px]]
Line 70: Line 90:  
[[File:Reefer IO settings.png|frameless|1000x1000px]]
 
[[File:Reefer IO settings.png|frameless|1000x1000px]]
   −
Data sending parameters (AVL ID) used for "DataCold Reefer" are these: 10040 - 10649.
+
Data sending parameters (AVL ID) used for "DataCold Reefer" are these: 10040 - 10649. For more in-depth information, please refer to '''[[FMB640 Teltonika Data Sending Parameters ID#Freezer|Data Sending Parameters page]].'''
    
==== Transcan2 Reefer ====
 
==== Transcan2 Reefer ====
Line 77: Line 97:  
[[File:Transcom IO settings.png|frameless|1000x1000px]]
 
[[File:Transcom IO settings.png|frameless|1000x1000px]]
   −
Data sending parameters (AVL ID) used for "Transcan2 Reefer" are these: 10683 - 10694.  
+
Data sending parameters (AVL ID) used for "Transcan2 Reefer" are these: 10683 - 10694. For more in-depth information, please refer to '''[[FMB640 Teltonika Data Sending Parameters ID#Freezer|Data Sending Parameters page]].'''
    
==== Touchprint Reefer ====
 
==== Touchprint Reefer ====
Line 84: Line 104:  
[[File:Touchprint Reefer IO settings.png|frameless|1000x1000px]]
 
[[File:Touchprint Reefer IO settings.png|frameless|1000x1000px]]
   −
Data sending parameters (AVL ID) used for "Touchprint Reefer" are these: 10695 - 10703.  
+
Data sending parameters (AVL ID) used for "Touchprint Reefer" are these: 10695 - 10703. For more in-depth information, please refer to '''[[FMB640 Teltonika Data Sending Parameters ID#Freezer|Data Sending Parameters page]].'''
 
+
      −
More information on Freezer I/O parameters could be found [[FMC640 Teltonika Data Sending Parameters ID#Freezer IO|here]].
      
[[Codec#Codec_8_Extended |Codec 8 Extended]] should be selected as the main data protocol in the “Protocol Settings” tab, which is located in the “System” section.
 
[[Codec#Codec_8_Extended |Codec 8 Extended]] should be selected as the main data protocol in the “Protocol Settings” tab, which is located in the “System” section.
    
[[image:Reefer3.png|center]]
 
[[image:Reefer3.png|center]]