Changes

1,293 bytes removed ,  16:17, 4 August 2023
no edit summary
Line 1: Line 1: −
'''FMB''' devices have pulse counter capability out of the box from firmware [[FMB firmware errata#03.25.05.Rev.00|03.25.05.Rev.00]] and later.
+
'''FMB''' devices have pulse counter capability out of the box from firmware 03.28.07.Rev.03 and later.
    
'''Use case:'''
 
'''Use case:'''
Line 5: Line 5:  
Pulse counter functionality enables the FMB devices to count digital impulses going to DIN1/DIN2. This means that 2 digital inputs of the FMB devices can now be used for precise fuel flow meter data reading. Impulse based fuel usage monitoring is much more accurate than a different type of fuel metering sensors and it makes the FMB devices a perfect solution for high fuel usage machines like cranes, construction vehicles, mining machines, agriculture equipment.
 
Pulse counter functionality enables the FMB devices to count digital impulses going to DIN1/DIN2. This means that 2 digital inputs of the FMB devices can now be used for precise fuel flow meter data reading. Impulse based fuel usage monitoring is much more accurate than a different type of fuel metering sensors and it makes the FMB devices a perfect solution for high fuel usage machines like cranes, construction vehicles, mining machines, agriculture equipment.
   −
'''How does it work?'''
+
'''Specification:'''
 
+
<table class="nd-othertables_2" style="width: 30%;">
When pulse counter I/O is enabled, then Pulse Counter DIN1/DIN2 will count every DIN1/DIN2 state change to HIGH and send the counted number with the next record. Pulse counter value is reset after sending the record.[[File:Pulse_counter.gif|center|]]Specification
+
<tr>
 
+
        <th style="width: 10%; text-align:center; vertical-align:middle;">Model</th>
Maximum supported frequency is 50Hz.
+
        <th style="width: 10%; text-align:center; vertical-align:middle;">DIN1 Max frequency, Hz
 
+
</th>
Maximum value 2147483647.
+
        <th style="width: 10%; text-align:center; vertical-align:middle;">DIN2 Max frequency, Hz
 
+
</th><th>Input Voltage threshold (DIN1)</th><th>Input Voltage threshold (DIN2)</th></tr>
High level:
+
        <tr>
 
+
        <td style="width: 10%; text-align:center; vertical-align:middle;">
Input Voltage threshold (DIN1) 7.5V
+
[[FMB920]]
 
+
</td>
Input Voltage threshold (DIN2) 2.5V
+
        <td style="width: 10%; text-align:center; vertical-align:middle;">2000</td>
 
+
<td style="width: 10%; text-align:center; vertical-align:middle;">-</td>
{| class="wikitable"
+
        <td style="width: 10%; text-align:center; vertical-align:middle;">7.5V</td>
|+
+
<td style="width: 10%; text-align:center; vertical-align:middle;">-</td>
!
+
        <tr>
!DIN1
+
        <td style="width: 10%; text-align:center; vertical-align:middle;">[[FMB110]]
Max frequency, Hz
  −
!DIN2
  −
Max frequency, Hz
  −
!Input Voltage threshold (DIN1)
  −
!Input Voltage threshold (DIN2)
  −
|-
  −
|[[FMB920]]
  −
|2000
  −
|<nowiki>-</nowiki>
  −
|7.5V
  −
|<nowiki>-</nowiki>
  −
|-
  −
|[[FMB110]]
  −
 
   
[[FMB120]]
 
[[FMB120]]
   Line 48: Line 34:     
[[FMB204]]
 
[[FMB204]]
 +
</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">50</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">2000</td>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">7.5V</td>
 +
<td style="width: 10%; text-align:center; vertical-align:middle;">2.5V</td>
 +
<td>
 +
   −
|50
+
</td><td>
|2000
  −
|7.5V
  −
|2.5V
  −
|-
  −
|[[FMB125]]
      +
 +
</td></tr>
 +
        <tr>
 +
        <td style="width: 10%; text-align:center; vertical-align:middle;">[[FMB125]]
 
[[FMM125]]
 
[[FMM125]]
    
[[FMC125]]
 
[[FMC125]]
|50
+
</td>
|<nowiki>-</nowiki>
+
        <td style="width: 10%; text-align:center; vertical-align:middle;">50</td>
|7.5V
+
         <td style="width: 10%; text-align:center; vertical-align:middle;">-</td>
| -
+
<td style="width: 10%; text-align:center; vertical-align:middle;">7.5V</td>
|}
+
<td style="width: 10%; text-align:center; vertical-align:middle;">-</td>
<table class="nd-othertables_2" style="width: 30%;">
+
<td></td><td></td></tr></table>
<tr>
+
 
         <th style="width: 10%; text-align:center; vertical-align:middle;">Input</th>
+
'''How does it work?'''
        <th style="width: 10%; text-align:center; vertical-align:middle;">Max frequency (Hz)</th>
  −
        <th style="width: 10%; text-align:center; vertical-align:middle;">Min Voltage threshold (V)</th>
     −
    </tr>
+
When pulse counter I/O is enabled, then Pulse Counter DIN1/DIN2 will count every DIN1/DIN2 state change to HIGH and send the counted number with the next record. Pulse counter value is reset after sending the record.[[File:Pulse_counter.gif|center|]]
        <tr>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">DIN1</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">50</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">7.5</td>
  −
    </tr>
  −
        <tr>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">DIN2</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">30 000</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">2.5</td>
  −
    </tr>
  −
        <tr>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">DIN3</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">30 000</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">2.5</td>
  −
    </tr>
  −
        <tr>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">DIN4</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">30 000</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">2.5</td>
  −
    </tr>
  −
        <tr>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">AIN1</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">10 000</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">2.5</td>
  −
    </tr>
  −
        <tr>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">AIN2</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">10 000</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">2.5</td>
  −
    </tr>
  −
        <tr>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">AIN3</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">10 000</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">2.5</td>
  −
    </tr>
  −
        <tr>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">AIN4</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">10 000</td>
  −
        <td style="width: 10%; text-align:center; vertical-align:middle;">2.5</td>
  −
    </tr>
  −
</table>