Line 25: |
Line 25: |
| | | |
| {| class="wikitable" style="text-align:left; width:100%;" | | {| class="wikitable" style="text-align:left; width:100%;" |
− | ! Parameter Name !! Custom Scenario 1 (ID) !! Custom Scenario 2 (ID) !! Custom Scenario 3 (ID) !! Min Value !! Max Value !! Default Value !! Description | + | ! Parameter ID !! Parameter Name !! Min Value !! Max Value !! Default Value !! Description |
| |- | | |- |
− | | Output Control || 19100 || 19130 || 19160 || 0 || 3 || 0 || Specifies the DOUT controlled by the scenario. Options include None, DOUT1, DOUT2, and DOUT3.
| + | | 19100, 19130, 19160 || Output Control || 0 || 3 || 0 || Specifies the DOUT controlled by the scenario: |
| + | * 0 – None |
| + | * 1 – DOUT1 |
| + | * 2 – DOUT2 |
| + | * 3 – DOUT3 |
| |- | | |- |
− | | Priority || 19101 || 19131 || 19161 || 0 || 3 || 0 || Sets the priority of the scenario. Options include None, Low, High, and Panic.
| + | | 19101, 19131, 19161 || Priority || 0 || 3 || 0 || Sets the scenario priority: |
| + | * 0 – None |
| + | * 1 – Low |
| + | * 2 – High |
| + | * 3 – Panic |
| |- | | |- |
− | | Permanent Output Control || 19124 || 19154 || 19184 || 0 || 1 || 0 || Enables continuous DOUT control as long as conditions are met.
| + | | 19124, 19154, 19184 || Permanent Output Control || 0 || 1 || 0 || Enables continuous DOUT control as long as conditions are met. |
| |- | | |- |
− | | DOUT ON Duration || 19102 || 19132 || 19162 || 100 ms || 65,000,000 ms || 200 ms || Duration for which DOUT remains ON when the scenario is active.
| + | | 19102, 19132, 19162 || DOUT ON Duration || 100 ms || 65,000,000 ms || 200 ms || Duration for which DOUT remains ON when the scenario is active. |
| |- | | |- |
− | | DOUT OFF Duration || 19103 || 19133 || 19163 || 0 || 65,000,000 ms || 200 ms || Duration for which DOUT remains OFF. A value of 0 means the DOUT stays ON continuously.
| + | | 19103, 19133, 19163 || DOUT OFF Duration || 0 || 65,000,000 ms || 200 ms || Duration for which DOUT remains OFF. A value of 0 means the DOUT stays ON continuously. |
| |- | | |- |
− | | Source #1 || 19105 || 19135 || 19165 || Device-specific || Device-specific || N/A || The primary I/O source for the trigger. This source cannot be ignored.
| + | | 19105, 19135, 19165 || Source #1 || Device-specific || Device-specific || IO element ID || The primary I/O source for the trigger. Cannot be ignored. |
| |- | | |- |
− | | Source #2 || 19110 || 19140 || 19170 || Device-specific || Device-specific || Ignored || The secondary I/O source. This source can be ignored.
| + | | 19110, 19140, 19170 || Source #2 || Device-specific || Device-specific || Ignored || The secondary I/O source. Can be ignored. |
| |- | | |- |
− | | Source #3 || 19116 || 19146 || 19176 || Device-specific || Device-specific || Ignored || The tertiary I/O source. This source can be ignored.
| + | | 19116, 19146, 19176 || Source #3 || Device-specific || Device-specific || Ignored || The tertiary I/O source. Can be ignored. |
| |- | | |- |
− | | Operand || 19106 || 19136 || 19166 || 0 || 6 || 0 || Defines the condition logic for the trigger. Options include On Exit, On Entrance, On Both, On Hysteresis, On Change, On Delta Change, and Is.
| + | | 19106, 19136, 19166 || Operand || 0 || 6 || 0 || Defines the condition logic for the trigger: |
| + | * 0 – On Exit |
| + | * 1 – On Entrance |
| + | * 2 – On Both |
| + | * 3 – On Hysteresis |
| + | * 4 – On Change |
| + | * 5 – On Delta Change |
| + | * 6 – Is |
| |- | | |- |
− | | Low Level || 19107 || 19137 || 19167 || Dynamic || Dynamic || 0 || Sets the lower threshold value for the source trigger.
| + | | 19107, 19137, 19167 || Low Level || Dynamic || Dynamic || 0 || Sets the lower threshold value for the source trigger. |
| |- | | |- |
− | | High Level || 19108 || 19138 || 19168 || Dynamic || Dynamic || 0 || Sets the upper threshold value for the source trigger.
| + | | 19108, 19138, 19168 || High Level || Dynamic || Dynamic || 0 || Sets the upper threshold value for the source trigger. |
| |- | | |- |
− | | Activation Delay Timer || 19109 || 19139 || 19169 || 0 s || 65,535 s || 0 || Time in seconds the condition must remain true for activation.
| + | | 19109, 19139, 19169 || Activation Delay Timer || 0 s || 65,535 s || 0 || Time (in seconds) the condition must remain true for activation. |
| |- | | |- |
− | | Logic || 19115 || 19145 || 19175 || 0 || 1 || 1 || Determines trigger evaluation logic. Options include OR (any trigger activates the scenario) and AND (all triggers must be true to activate the scenario).
| + | | 19115, 19145, 19175 || Logic || 0 || 1 || 1 || Determines trigger evaluation logic: |
| + | * 0 – OR (any trigger activates the scenario) |
| + | * 1 – AND (all triggers must be true to activate the scenario) |
| |} | | |} |
| | | |