Changes

no edit summary
Line 10: Line 10:  
**Digital Input (DIN1 ON – ignition on, DIN1 OFF – ignition off);
 
**Digital Input (DIN1 ON – ignition on, DIN1 OFF – ignition off);
 
**Movement (if accelerometer/movement sensor detects movement then ignition is on, if movement stops – ignition is off).
 
**Movement (if accelerometer/movement sensor detects movement then ignition is on, if movement stops – ignition is off).
 +
    
{| class="wikitable"
 
{| class="wikitable"
Line 31: Line 32:  
| vertical-align: bottom;" colspan="2"| While GNSS fix is unavailable, Object Motion Detection Settings are working like in Msensor mode
 
| vertical-align: bottom;" colspan="2"| While GNSS fix is unavailable, Object Motion Detection Settings are working like in Msensor mode
 
|}
 
|}
 +
    
Static Navigation Mode is a filter, which filters out track jumps when the object is stationary. If Static navigation filter is disabled, it will apply no changes on GNSS data. If Static navigation filter is enabled, it will filter changes in GNSS position if no movement is detected (depends on Object Motion Detection Settings). It allows filtering GNSS jumps when object is parked (is not moving) and GNSS position is still traced.
 
Static Navigation Mode is a filter, which filters out track jumps when the object is stationary. If Static navigation filter is disabled, it will apply no changes on GNSS data. If Static navigation filter is enabled, it will filter changes in GNSS position if no movement is detected (depends on Object Motion Detection Settings). It allows filtering GNSS jumps when object is parked (is not moving) and GNSS position is still traced.
 +
    
[[Image:FM36_Sys_Settings.jpg|800px|none]]
 
[[Image:FM36_Sys_Settings.jpg|800px|none]]
 +
    
Also if Power Voltage is chosen for ignition source there is possibility to choose Manual ignition detection or automatic ignition detection. For manual ignition user has to choose power voltage levels by himself. For  
 
Also if Power Voltage is chosen for ignition source there is possibility to choose Manual ignition detection or automatic ignition detection. For manual ignition user has to choose power voltage levels by himself. For  
 
automatic ignition {{{model|FM36YX}}} automatically detects ignition, ignition is on if power voltage is between 13,2 – 16 V, or 27 – 32 V.
 
automatic ignition {{{model|FM36YX}}} automatically detects ignition, ignition is on if power voltage is between 13,2 – 16 V, or 27 – 32 V.