Changes

Line 35: Line 35:  
<br>
 
<br>
 
*<span style="background-color:#91d4b9;">11801</span> - Eventual settings (0 - Disable, 1 - Enable), if disabled - trip settings will come with periodical data.
 
*<span style="background-color:#91d4b9;">11801</span> - Eventual settings (0 - Disable, 1 - Enable), if disabled - trip settings will come with periodical data.
<br>
+
 
*11802 - Mode (0 - Continuous, 1 Between Records). If Between Records option is selected distance will be counted until any record is made. Then odometer will be reset to zero and start counting until next record is made.
+
*11802 - Mode (0 - Continuous, 1 Between Records). If Between Records option is selected - distance will be counted until any record is made. Then odometer will be reset to zero and start counting until next record is made. If Continues option is selected - distance will continue counting between trip start and trip stop and odometer will not reset.
 
*11803 - Start Speed (km/h).
 
*11803 - Start Speed (km/h).
 
*11804 - Ignition OFF timeout (s).
 
*11804 - Ignition OFF timeout (s).