Changes

no edit summary
Line 4: Line 4:     
===Connecting Iridium device to {{{device|}}}===
 
===Connecting Iridium device to {{{device|}}}===
In order to properly connect the Iridium device to {{{device|}}}, Iridium has to be connected to the device via RS-232 - COM1 or COM2 (paminėt kur TX/RX jungt ir pridėt screenshot COM pinų). Additionally '''Pin No. 6''' - power control (reference in the image below) must be connected to one of the {{{device|}}} DOUTs (1/2/3/4), in order to allow the device to power ON/OFF Iridium device on demand.
+
In order to properly connect the Iridium device to {{{device|}}}, Iridium has to be connected to the device via RS-232 - COM1 or COM2 (with RJ-45 connector, where 4 pin is GND, 5 pin is RS232 Rx and 6 PIN is RS232 Tx). Additionally '''Pin No. 6''' - power control (reference in the image below) must be connected to one of the {{{device|}}} DOUTs (1/2/3/4), in order to allow the device to power ON/OFF Iridium device on demand.
   −
Iridium Edge pinout:  
+
Iridium Edge pinout and RS232 COM 1/2 connection:  
    
[[File:Iridium Edge pinout.png|left]]
 
[[File:Iridium Edge pinout.png|left]]
 +
[[File:FM64-RS232.png|right]]
    
{| class="nd-othertables_2" style="width:100%;"  
 
{| class="nd-othertables_2" style="width:100%;"  

Navigation menu