Line 1: |
Line 1: |
− | {{Template:FMB I/O settings|model=FMB125}} | + | {{Template:FMB I/O settings|model=FMB125|ctrIO=[https://wiki.teltonika-gps.com/index.php?title=FMB125_I/O_settings I/O settings]|ctrCAN=[[FMB120 CAN adapters|FMB125 with LV-CAN200 and ALL-CAN300 CAN adapters]] |
| + | |sms_text_tmt= |
| + | }} |
| + | |
| + | ==FMB125 RS-232/RS-485 parameter configuration== |
| + | |
| + | [[Image:Fmb125_uart_mode.png|300px|right]] |
| + | FMB-125 supports RS-232 and RS-485 serial standards and can be configured to work in different RS-232/RS-485 modes. More information about each mode is provided in [[FMB125 RS-232 and RS-485|RS-232 and RS-485]].<br/>Only one mode may be selected at a time: |
| + | * <span style=color:#F6A83E>Disable</span> - Disable RS-232/RS-485 functionality; |
| + | * <span style=color:#F6A83E>RS232</span> - Select RS-232 functionality; |
| + | * <span style=color:#F6A83E>RS485</span> - Select RS-485 functionality. |
| + | |
| + | ===RS-232 modes=== |
| + | ---- |
| + | RS-232 supports following modes: |
| + | * <span style=color:#F6A83E>Log Mode</span> – suitable for debugging/logging; |
| + | * <span style=color:#F6A83E>NMEA</span> – NMEA logs are transferred; |
| + | * <span style=color:#F6A83E>LLS</span> – LLS sensor support; |
| + | * <span style=color:#F6A83E>LCD</span> – external LCD support; |
| + | * <span style=color:#F6A83E>RFID HID</span> – RFID HID reader support; |
| + | * <span style=color:#F6A83E>RFID MF7</span> - RFID MF7 reader support; |
| + | * <span style=color:#F6A83E>Garmin FMI</span> – Garmin support; |
| + | * <span style=color:#F6A83E>TCP ASCII</span> – for routing any input string from external device to the server; |
| + | * <span style=color:#F6A83E>TCP Binary</span> – for routing any binary input data from external device to the server. |
| + | |
| + | ====RS-232 baudrate and parity==== |
| + | |
| + | Every RS-232 mode supports different baudrates, but each mode has its own default baudrate value. Default baudrate and parity values for each RS-232 mode are provided in the table below. |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! style="width: 100px; background: black; color: white;" rowspan=3 | Mode |
| + | ! style="width: 300px; background: black; color: white;" colspan=3 | Default settings |
| + | |- |
| + | | style="width: 75px;text-align: left; vertical-align: top;" colspan=2 | RS-232 |
| + | | style="width: 75px;text-align: left; vertical-align: top;" | RS-485 |
| + | |- |
| + | | style="width: 75px;text-align: left; vertical-align: top;" | Baudrate |
| + | | style="width: 75px;text-align: left; vertical-align: top;" | Parity |
| + | | style="width: 75px;text-align: left; vertical-align: top;" | Baudrate |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | Log Mode |
| + | | style="text-align: left; vertical-align: top;" | 115200 |
| + | | style="text-align: left; vertical-align: top;" rowspan=9 | None |
| + | | style="text-align: left; vertical-align: top;" | 115200 |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | NMEA |
| + | | style="text-align: left; vertical-align: top;" | 115200 |
| + | | style="text-align: left; vertical-align: top;" | 115200 |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | LLS |
| + | | style="text-align: left; vertical-align: top;" | 19200 |
| + | | style="text-align: left; vertical-align: top;" | 19200 |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | LCD |
| + | | style="text-align: left; vertical-align: top;" | 57600 |
| + | | style="text-align: left; vertical-align: top;" | - |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | RFID HID |
| + | | style="text-align: left; vertical-align: top;" | 57600 |
| + | | style="text-align: left; vertical-align: top;" | - |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | RFID MF7 |
| + | | style="text-align: left; vertical-align: top;" | 9600 |
| + | | style="text-align: left; vertical-align: top;" | - |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | Garmin FMI |
| + | | style="text-align: left; vertical-align: top;" | 9600 |
| + | | style="text-align: left; vertical-align: top;" | - |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | TCP ASCII |
| + | | style="text-align: left; vertical-align: top;" | 115200 |
| + | | style="text-align: left; vertical-align: top;" | 57600 |
| + | |- |
| + | ! style="text-align: left; vertical-align: top;" | TCP Binary |
| + | | style="text-align: left; vertical-align: top;" | 115200 |
| + | | style="text-align: left; vertical-align: top;" | 57600 |
| + | |- |
| + | |} |
| + | |
| + | ====RS-232 TCP Binary mode settings==== |
| + | |
| + | [[Image:Fmb125_tcp_binary_mode.png|300px|right]] |
| + | RS-232 ''TCP Binary mode'' has additional configurable parameters for advanced data filtering as shown on the right hand side figure. |
| + | |
| + | ====RS-232 Garmin mode settings==== |
| + | |
| + | [[Image:Fmb125_garmin_mode.png|300px|right]] |
| + | ''Garmin FMI mode'' has addditional filtering capabilities. It is possible to filter Ping and Unicode packets. If <span style=color:#F6A83E>Ping Filter</span> is enabled, then Ping packets are blocked. When <span style=color:#F6A83E>Unicode Filter</span> is enabled Unicode packets are not sent to the server. Both filters may be enabled for simultaneous effect.<br/><br/><br/> |
| + | |
| + | ===RS-485 modes=== |
| + | ---- |
| + | RS-485 supports several modes: |
| + | * <span style=color:#F6A83E>Log Mode</span> – suitable for debugging/logging; |
| + | * <span style=color:#F6A83E>NMEA</span> – NMEA logs are transferred; |
| + | * <span style=color:#F6A83E>LLS</span> – LLS sensors support; |
| + | * <span style=color:#F6A83E>TCP ASCII</span> – for routing any input string from external device to the server; |
| + | * <span style=color:#F6A83E>TCP Binary</span> – for routing any binary input data from external device to the server. |
| + | |
| + | ====RS-485 baudrate==== |
| + | Every RS-485 mode supports different baudrates, but each mode has its own default baudrate value. Default baudrate values for each RS-485 mode are provided in the table above. |
| + | |
| + | ====RS-485 LLS sensors==== |
| + | |
| + | [[Image:Fmb125_lls_sensors.png|300px|right]] |
| + | LLS addresses may be configured for 5 LLS sensors. If at least one LLS sensor is connected to FMB125 when configuring device using configurator, LLS sensor ID will be entered automatically. |
| + | [[Category:FMB125 Configuration]] |