ATEX certification is given to equipment that has gone through rigorous testing outlined by European Union directives. Products that are ATEX compliant have been proved safe to use in specific environments with explosive atmospheres, according to the zone/s they are certified to be used in.
 
ATEX certification is given to equipment that has gone through rigorous testing outlined by European Union directives. Products that are ATEX compliant have been proved safe to use in specific environments with explosive atmospheres, according to the zone/s they are certified to be used in.
      
==Description==
 
==Description==
Line 21: Line 20:     
==Meanings of Letters and Numbers==
 
==Meanings of Letters and Numbers==
[[File:ATEX logo explanation.PNG|left|480px]]
+
[[File:ATEX logo explanation.PNG|thumb|left|Issued certification marking for devices|480px]]
    
'''II''' - Equipment Group <br>
 
'''II''' - Equipment Group <br>
Line 32: Line 31:  
'''Gb''' - Equipment Protection Level<br>
 
'''Gb''' - Equipment Protection Level<br>
   −
'''Issued certification marking added on devices:'''
+
<br><br>'''II''': There are two equipment groups - Group I, which concerns mines and is very restrictive due to the highly volatile methane gas and dust present, and Group II, which relates to all other above-ground industries.  
 
  −
'''II''': There are two equipment groups - Group I, which concerns mines and is very restrictive due to the highly volatile methane gas and dust present, and Group II, which relates to all other above-ground industries.  
      
'''2''': There are three area category types, with Category 1 requiring a very high level of protection and defined as an area having a permanent or prolonged risk of explosions (Zone 0), Category 2 which requires a high level of protection and has a frequent risk of an explosive mix being present in the air (Zone 1), and Category 3, specified as requiring a normal level of protection with a small chance of an explosive mix forming (Zone 2).  
 
'''2''': There are three area category types, with Category 1 requiring a very high level of protection and defined as an area having a permanent or prolonged risk of explosions (Zone 0), Category 2 which requires a high level of protection and has a frequent risk of an explosive mix being present in the air (Zone 1), and Category 3, specified as requiring a normal level of protection with a small chance of an explosive mix forming (Zone 2).  