==2024.10.03: PCB changes==
We would like to inform you that starting from January, 2025, there will be changes in the PCB's modification of our FMM125 devices. These changes affect FMM130, FMM230 and FMM125 devices.
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change description
|-
| style="text-align: left; background: white;" |Change type
| colspan="2" style="text-align: left; background: white;" |Mechanical part changes
|-
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| colspan="2" style="width: 908px; text-align: left; background: white;" |Change of mechanical components within PCB:
#Replaced the LIS3DH accelerometer on the bottom layer with an LIS2DH12 on a neighbouring footprint. Additionally, the accompanying capacitors and resistors were replaced.
#The top layer remains unchanged.
|-
| style="text-align: left; background: white;" |Old Version: <br>  [[File:PCBOLD_FMM130_2024.10.04.png|center|250px]] [[File:PCBOLD1_FMM130_2024.10.04.png|center|250px]]
| style="text-align: left; background: white;" |New Version: <br>  [[File:PCBNEW_FMM130_2024.10.04.png|center|250px]] [[File:PCBNEW1_FMM130_2024.10.04.png|center|250px]]
|-
| style="text-align: left; background: white;" |Change reasons
| colspan="2" style="text-align: left; background: white;" |The PCB shape in the afore-mentioned devices is updated to streamline the manufacturing process, making it more efficient.
|-
| style="text-align: left; background: white;" | Product release date
| colspan="2" style="text-align: left; background: white;" |January, 2025
|-
|}
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Affected products
|-
| style="width: 221px; text-align: left; background: white;" |Model
| style="width: 448px; text-align: left; background: white;" |Affected order codes
| style="width: 448px; text-align: left; background: white;" |Order code changes
|-
| style="text-align: left; background: white;" |FMM125
| style="text-align: left; background: white;" |FMM125******* order codes
| style="text-align: left; background: white;" |PCB's mechanical part changes
|-
|}
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change impact
|-
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| colspan="2" style="width: 908px; text-align: left; background: white;" |No risk factors encountered with this change.
|-
| style="text-align: left; background: white;" |Suggested implementation plan
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
|-
|}
{| class="wikitable"
|+
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
|-
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
|-
|}
==2024.08.20: Base firmware update==
We would like to inform you about the base firmware update for FMM125 starting from September, 2024. New production firmware version will be '''03.29.00.Rev.21'''
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change description
|-
| style="text-align: left; background: white;" |Change type
| colspan="2" style="text-align: left; background: white;" |Firmware update
|-
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: [[FMM125 firmware errata]]
|-
| style="text-align: left; background: white;" |Old version: <br> 03.29.00.Rev.18
| style="text-align: left; background: white;" |New version: <br> 03.29.00.Rev.21
|-
| style="text-align: left; background: white;" |Change reasons
| colspan="2" style="text-align: left; background: white;" |FMM125 base firmware version update for modifications with BG95-M3 module
|-
| style="text-align: left; background: white;" | Product release date
| colspan="2" style="text-align: left; background: white;" |2024 September
|-
|}
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Affected products
|-
| style="width: 221px; text-align: left; background: white;" |Model
| style="width: 448px; text-align: left; background: white;" |Affected order codes
| style="width: 448px; text-align: left; background: white;" |Order code changes
|-
| style="text-align: left; background: white;" |FMM125
| style="text-align: left; background: white;" |
* FMM1252P***** with 03.29.00.Rev.18 firmware
| style="text-align: left; background: white;" |New firmware version
|-
|}
{| class="wikitable"
|+
! colspan="3" style="text-align: left; background: white;" |Change impact
|-
| style="width: 221px; text-align: left; background: white;" |Risk assessment
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
|-
| style="text-align: left; background: white;" |Suggested implementation plan
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
|-
|}
==2024.07.29: PCB changes==
==2024.07.29: PCB changes==
We would like to inform you that starting from August, 2024, there will be changes in the PCB's modification of our FMM125 devices. These changes affect FMM130, FMM230 and FMM125 devices.
We would like to inform you that starting from August, 2024, there will be changes in the PCB's modification of our FMM125 devices. These changes affect FMM130, FMM230 and FMM125 devices.
Line 41: Line 145:
|-
|-
| style="width: 221px; text-align: left; background: white;" |Model
| style="width: 221px; text-align: left; background: white;" |Model
| style="width: 448px; text-align: left; background: white;" |Affected order codes: '''FMM130'''******* order codes
| style="width: 448px; text-align: left; background: white;" |Affected order codes: '''FMM125'''******* order codes
| style="width: 448px; text-align: left; background: white;" |Affected order codes: '''FMM130'''******* order codes
| style="width: 448px; text-align: left; background: white;" |Affected order codes: '''FMM125'''******* order codes
|-
|-
| style="text-align: left; background: white;" |'''FMM130'''
| style="text-align: left; background: white;" |'''FMM125'''
| style="text-align: left; background: white;" |PCB's mechanical part changes
| style="text-align: left; background: white;" |PCB's mechanical part changes
| style="text-align: left; background: white;" |PCB's mechanical part changes
| style="text-align: left; background: white;" |PCB's mechanical part changes
Line 62: Line 166:
|-
|-
|}
|}
==2024.05.13: Base firmware update==
==2024.05.13: Base firmware update==
We would like to inform you about the base firmware update for FMM125 starting from June, 2024. New production firmware version will be '''03.29.00.Rev.18'''
We would like to inform you about the base firmware update for FMM125 starting from June, 2024. New production firmware version will be '''03.29.00.Rev.18'''