Difference between revisions of "FMC130 Product Change Notifications"
m (Text replacement - "Bluetooth(?!®)" to "Bluetooth®") |
|||
(26 intermediate revisions by 4 users not shown) | |||
Line 2: | Line 2: | ||
| product_name = FMC130 tracking device | | product_name = FMC130 tracking device | ||
}} | }} | ||
+ | |||
+ | ==2024.09.10: PCB changes== | ||
+ | We would like to inform you that starting from December, 2024, there will be changes in the PCB's modification of our FMC130 devices. These changes affect FMC125, FMC225, FMC130, FMC230 and FMC234 devices. | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Change description | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Change type | ||
+ | | colspan="2" style="text-align: left; background: white;" |Mechanical part changes | ||
+ | |- | ||
+ | | rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description | ||
+ | | colspan="2" style="width: 908px; text-align: left; background: white;" |Change of mechanical components within PCB: | ||
+ | |||
+ | # The DOUT is derived from discrete components. | ||
+ | # No longer utilizes a dedicated part for the DOUT functionality. | ||
+ | # Features simple overvoltage protection for the RS485 interface. | ||
+ | # The microcontroller unit (MCU) has been upgraded from a Geehy MCU to an STM MCU. | ||
+ | |||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Old version:<br><br> | ||
+ | |||
+ | [[File:PCB1.png|250px]] | ||
+ | |||
+ | [[File:PCB2.png|250px]]<br> | ||
+ | <br> | ||
+ | |||
+ | | style="text-align: left; background: white;" |New version:<br> | ||
+ | [[File:PCB3.png|250px]]<br> | ||
+ | |||
+ | [[File:PCB4.png|250px]] | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Change reasons | ||
+ | | colspan="2" style="text-align: left; background: white;" |The PCB shape in the afore-mentioned devices is updated to streamline the manufacturing process, making it more efficient. | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" | Product release date | ||
+ | | colspan="2" style="text-align: left; background: white;" | December, 2024 | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Affected products | ||
+ | |- | ||
+ | | style="width: 221px; text-align: left; background: white;" |Model | ||
+ | | style="width: 448px; text-align: left; background: white;" |Affected order codes | ||
+ | | style="width: 448px; text-align: left; background: white;" |Order code changes | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |FMC130 | ||
+ | | style="text-align: left; background: white;" |FMC130******* order codes | ||
+ | | style="text-align: left; background: white;" |PCB's mechanical part changes | ||
+ | |- | ||
+ | |} | ||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Change impact | ||
+ | |- | ||
+ | | style="width: 221px; text-align: left; background: white;" |Risk assessment | ||
+ | | colspan="2" style="width: 908px; text-align: left; background: white;" | No risk factors encountered with this change. | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Suggested implementation plan | ||
+ | | colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process. | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt | ||
+ | |- | ||
+ | | colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | ==2024 June: PCB changes== | ||
+ | We would like to inform you that starting from June, 2024, there will be changes in the PCB's modification of our FMC130 devices. These changes affect FMC125, FMC225, FMC130, FMC230 and FMC234 devices. | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Change description | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Change type | ||
+ | | colspan="2" style="text-align: left; background: white;" |Mechanical part changes | ||
+ | |- | ||
+ | | rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description | ||
+ | | colspan="2" style="width: 908px; text-align: left; background: white;" |Change of mechanical components within PCB: | ||
+ | |||
+ | # U4100 changed to APM32F003F6U6 | ||
+ | # Changed SWD pinout | ||
+ | # Added QR to BOT side | ||
+ | # Icreased TestPoint diameter | ||
+ | # Added TestPoint for reset pin(clearly visible) | ||
+ | # Removed modem USB TestPoint(clearly visible) | ||
+ | # Removed RF socket and cutout (Major change, clearly visible) | ||
+ | # Remade Palette just like in FMB1X0 project | ||
+ | # Discrete DOUT -> DOUT chip (clearly visible) | ||
+ | # Changed fuse to a smaller footprint (clearly visible) | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Old version:<br><br> | ||
+ | |||
+ | [[File:C TOP -1.png|250px]] | ||
+ | |||
+ | [[File:C BOT -1.png|250px]]<br> | ||
+ | <br> | ||
+ | |||
+ | | style="text-align: left; background: white;" |New version:<br> | ||
+ | [[File:F TOP -3.png|250px]]<br> | ||
+ | |||
+ | [[File:F BOT -3.png|250px]] | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Change reasons | ||
+ | | colspan="2" style="text-align: left; background: white;" |The PCB shape in the afore-mentioned devices is updated to streamline the manufacturing process, making it more efficient. | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" | Product release date | ||
+ | | colspan="2" style="text-align: left; background: white;" |2024 June | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Affected products | ||
+ | |- | ||
+ | | style="width: 221px; text-align: left; background: white;" |Model | ||
+ | | style="width: 448px; text-align: left; background: white;" |Affected order codes | ||
+ | | style="width: 448px; text-align: left; background: white;" |Order code changes | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |FMC130 | ||
+ | | style="text-align: left; background: white;" |FMC130******* order codes | ||
+ | | style="text-align: left; background: white;" |PCB's mechanical part changes | ||
+ | |- | ||
+ | |} | ||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Change impact | ||
+ | |- | ||
+ | | style="width: 221px; text-align: left; background: white;" |Risk assessment | ||
+ | | colspan="2" style="width: 908px; text-align: left; background: white;" | No risk factors encountered with this change. | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Suggested implementation plan | ||
+ | | colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process. | ||
+ | |- | ||
+ | |} | ||
+ | ==2024.05.13: Base firmware update== | ||
+ | We would like to inform you about the base firmware update for FMC130 starting from June, 2024. New production firmware version will be '''03.29.00.Rev.18''' | ||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Change description | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Change type | ||
+ | | colspan="2" style="text-align: left; background: white;" |Firmware update | ||
+ | |- | ||
+ | | rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description | ||
+ | | colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Old version: <br> 03.29.00.Rev.13 | ||
+ | | style="text-align: left; background: white;" |New version: <br> 03.29.00.Rev.18 | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Change reasons | ||
+ | | colspan="2" style="text-align: left; background: white;" |FMC130 base firmware version update for modifications with SLM320-LA module, SLM320-E1 module and SLM320-E2 module | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" | Product release date | ||
+ | | colspan="2" style="text-align: left; background: white;" |2024 June | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Affected products | ||
+ | |- | ||
+ | | style="width: 221px; text-align: left; background: white;" |Model | ||
+ | | style="width: 448px; text-align: left; background: white;" |Affected order codes | ||
+ | | style="width: 448px; text-align: left; background: white;" |Order code changes | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |FMC130 | ||
+ | | style="text-align: left; background: white;" | | ||
+ | * FMC1304O***** with 03.29.00.Rev.13 firmware | ||
+ | * FMC130KY***** with 03.29.00.Rev.13 firmware | ||
+ | * FMC130LK***** with 03.29.00.Rev.13 firmware | ||
+ | * FMC130NQ***** with 03.29.00.Rev.13 firmware | ||
+ | * FMC130QL***** with 03.29.00.Rev.13 firmware | ||
+ | | style="text-align: left; background: white;" |New firmware version | ||
+ | |- | ||
+ | |} | ||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Change impact | ||
+ | |- | ||
+ | | style="width: 221px; text-align: left; background: white;" |Risk assessment | ||
+ | | colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Suggested implementation plan | ||
+ | | colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | ==2024.01.05: GNSS antenna changes== | ||
+ | We would like to inform you that starting from February 2024, there will be a change in the manufacturing process of our FMC130 devices. We will be transitioning to utilize Surface Mount Device (SMD) manufactured GNSS antennas, which will replace the existing Dual-In-line Package (DIP) technique. | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Change description | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Change type | ||
+ | | colspan="2" style="text-align: left; background: white;" | Mechanical part changes | ||
+ | |- | ||
+ | | rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description | ||
+ | | colspan="2" style="width: 908px; text-align: left; background: white;" |Change of the manufacturing process, transition from Dual-In-line Package (DIP) to Surface Mount Device (SMD) process. | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Old version: <br> Dual-In-Line Package (DIP) manufactured antennas [[File:GNSS antenna Dual-In-Line Package (DIP) v1.png|center]]<br> | ||
+ | Antenna size: 25x25x4 mm<br> | ||
+ | Center frequency: 1575.42 MHz, 1602 MHz<br> | ||
+ | VSWR: <1.1<br> | ||
+ | Average Gain: -2.6 dB<br> | ||
+ | Return loss: <-25 dB<br> | ||
+ | | style="text-align: left; background: white;" |New version: <br> Surface Mount Device (SMD) manufactured antennas [[File:GNSS antenna DSurface Mount Device (SMD) v1.png|center]]<br> | ||
+ | Antenna size: 25x25x4 mm<br> | ||
+ | Center frequency 1575.42 MHz, 1602 MHz<br> | ||
+ | VSWR: <1.9<br> | ||
+ | Average Gain: -2.5 dB<br> | ||
+ | Return loss: <-9 dB<br> | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Change reasons | ||
+ | | colspan="2" style="text-align: left; background: white;" | Standardization of GNSS antennas throughout device portfolio and manufacturing efficiency improvements.<br> | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Release date | ||
+ | | colspan="2" style="text-align: left; background: white;" |February, 2024. | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Affected products | ||
+ | |- | ||
+ | | style="width: 221px; text-align: left; background: white;" |Model | ||
+ | | style="width: 448px; text-align: left; background: white;" |Affected order codes | ||
+ | | style="width: 448px; text-align: left; background: white;" |Order code changes | ||
+ | |- | ||
+ | | style="text-align: left; background: white;" |FMC130 | ||
+ | | style="text-align: left; background: white;" |FMC130******* order codes | ||
+ | | style="text-align: left; background: white;" |SMD manufactured antennas | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="text-align: left; background: white;" |Change impact | ||
+ | |- | ||
+ | | style="width: 221px; text-align: left; background: white;" |Risk assessment | ||
+ | | colspan="2" style="width: 908px; text-align: left; background: white;" | During transition period clients might receive devices with previous DIP manufactured antennas. The transition period can last from February to June. | ||
+ | |||
+ | Since the change of the GNSS antenna is visible visually on PCB, in order to avoid problems at the customs of certain countries, we suggest informing the relevant authorities about the change of the GNSS antenna. The new SMD GNSS antenna provides an equivalent track quality and performance level, as verified through testing. Testing results: | ||
+ | {| class="wikitable" | ||
+ | |+ Caption text | ||
+ | |- | ||
+ | ! '''Device''' !! '''Antenna''' !! '''Avg. Difference from precise track [m]*''' | ||
+ | |- | ||
+ | | FMC130_211|| SMD|| 3.30 | ||
+ | |- | ||
+ | | FMC130_264|| SMD|| 2.94 | ||
+ | |- | ||
+ | | FMC130_351|| SMD|| 2.65 | ||
+ | |- | ||
+ | | FMC130_476|| DIP|| 4.23 | ||
+ | |- | ||
+ | | FMC130_640|| DIP|| 3.52 | ||
+ | |} | ||
+ | |||
+ | * Avg. Difference from precise track - measured by comparing positioning data from devices and RTK (Real-time kinematic positioning) system data which is considered precise data. The smaller avg. difference from precise track, means better track quality. | ||
+ | |||
+ | ** Testing is done inside vehicle interior. Devices were placed on the carpet, with front passenger seat removed. It is worth noting that GNSS signal is heavily influenced by the exact location device(s) is(are) placed. | ||
+ | |||
+ | |- | ||
+ | | style="text-align: left; background: white;" |Suggested implementation plan | ||
+ | | colspan="2" style="text-align: left; background: white;" |No implementation plan is needed. | ||
+ | |- | ||
+ | |} | ||
+ | |||
+ | {| class="wikitable" | ||
+ | |+ | ||
+ | ! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt | ||
+ | |- | ||
+ | | colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. | ||
+ | |- | ||
+ | |} | ||
+ | |||
==2023.12.15: Base firmware update== | ==2023.12.15: Base firmware update== | ||
We would like to inform you about the base firmware update for FMC130 starting from December 15th, 2023. New production firmware version will be '''03.29.00.Rev.13''' | We would like to inform you about the base firmware update for FMC130 starting from December 15th, 2023. New production firmware version will be '''03.29.00.Rev.13''' | ||
Line 49: | Line 332: | ||
|- | |- | ||
|} | |} | ||
+ | |||
==2023.12.01: Certification Engraving Update== | ==2023.12.01: Certification Engraving Update== | ||
Latest revision as of 14:09, 8 October 2024
Main Page > Advanced Trackers > FMC130 > FMC130 Product Change NotificationsProduct change notifications (PCN) is the way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, firmware changes, changes to package contents, etc. This page stores information regarding changes to the FMC130 tracking device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).
2024.09.10: PCB changes
We would like to inform you that starting from December, 2024, there will be changes in the PCB's modification of our FMC130 devices. These changes affect FMC125, FMC225, FMC130, FMC230 and FMC234 devices.
Change description | ||
---|---|---|
Change type | Mechanical part changes | |
Detailed description | Change of mechanical components within PCB:
| |
Old version: |
New version: | |
Change reasons | The PCB shape in the afore-mentioned devices is updated to streamline the manufacturing process, making it more efficient. | |
Product release date | December, 2024 |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes | PCB's mechanical part changes |
Change impact | ||
---|---|---|
Risk assessment | No risk factors encountered with this change. | |
Suggested implementation plan | Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process. |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. |
2024 June: PCB changes
We would like to inform you that starting from June, 2024, there will be changes in the PCB's modification of our FMC130 devices. These changes affect FMC125, FMC225, FMC130, FMC230 and FMC234 devices.
Change description | ||
---|---|---|
Change type | Mechanical part changes | |
Detailed description | Change of mechanical components within PCB:
| |
Old version: |
New version: | |
Change reasons | The PCB shape in the afore-mentioned devices is updated to streamline the manufacturing process, making it more efficient. | |
Product release date | 2024 June |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes | PCB's mechanical part changes |
Change impact | ||
---|---|---|
Risk assessment | No risk factors encountered with this change. | |
Suggested implementation plan | Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process. |
2024.05.13: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from June, 2024. New production firmware version will be 03.29.00.Rev.18
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: 03.29.00.Rev.13 |
New version: 03.29.00.Rev.18 | |
Change reasons | FMC130 base firmware version update for modifications with SLM320-LA module, SLM320-E1 module and SLM320-E2 module | |
Product release date | 2024 June |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 |
|
New firmware version |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2024.01.05: GNSS antenna changes
We would like to inform you that starting from February 2024, there will be a change in the manufacturing process of our FMC130 devices. We will be transitioning to utilize Surface Mount Device (SMD) manufactured GNSS antennas, which will replace the existing Dual-In-line Package (DIP) technique.
Change description | ||
---|---|---|
Change type | Mechanical part changes | |
Detailed description | Change of the manufacturing process, transition from Dual-In-line Package (DIP) to Surface Mount Device (SMD) process. | |
Old version: Dual-In-Line Package (DIP) manufactured antennas Antenna size: 25x25x4 mm |
New version: Surface Mount Device (SMD) manufactured antennas Antenna size: 25x25x4 mm | |
Change reasons | Standardization of GNSS antennas throughout device portfolio and manufacturing efficiency improvements. | |
Release date | February, 2024. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes | SMD manufactured antennas |
Change impact | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Risk assessment | During transition period clients might receive devices with previous DIP manufactured antennas. The transition period can last from February to June.
Since the change of the GNSS antenna is visible visually on PCB, in order to avoid problems at the customs of certain countries, we suggest informing the relevant authorities about the change of the GNSS antenna. The new SMD GNSS antenna provides an equivalent track quality and performance level, as verified through testing. Testing results:
* Avg. Difference from precise track - measured by comparing positioning data from devices and RTK (Real-time kinematic positioning) system data which is considered precise data. The smaller avg. difference from precise track, means better track quality. ** Testing is done inside vehicle interior. Devices were placed on the carpet, with front passenger seat removed. It is worth noting that GNSS signal is heavily influenced by the exact location device(s) is(are) placed. | |||||||||||||||||||
Suggested implementation plan | No implementation plan is needed. |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. |
2023.12.15: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from December 15th, 2023. New production firmware version will be 03.29.00.Rev.13
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: 03.27.13.Rev.443 |
New version: 03.29.00.Rev.13 | |
Change reasons | FMC130 base firmware version update for modifications with SLM320-LA module, SLM320-E1 module and SLM320-E2 module | |
Product release date | 2023 December |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* with 03.27.13.Rev.443 will be replaced to FMC130******* with base firmware | New firmware version |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2023.12.01: Certification Engraving Update
Change description | ||
---|---|---|
Change type | Internal | |
Detailed description | The specifications of laser engraving devices have undergone modifications subsequent to their certification by Anatel and Bluetooth® SIG, ensuring compliance with rigorous standards. These changes affect FMC130-MCIB0 and FMC230-MCIB0 devices. | |
Old laser engraving: |
New laser engraving: | |
Change reasons | The devices have received approval from both Anatel certification and compliance with the Bluetooth® SIG standard. These changes affect FMC130-MCIB0 and FMC230-MCIB0 devices. | |
Release date | December, 2023 |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130-MCIB0 | Updated laser engraving. |
Change impact | ||
---|---|---|
Risk assessment | During the transition period clients might receive devices with old laser engraving. | |
Suggested implementation plan | No implementation plan is needed. |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. |
2023.07.01: SLM320 Modem Firware Update
We would like to inform you, that SLM320 modem firmware has been updated for the FMC130 device and it is updated in factory from July, 2023.
Change description | ||
---|---|---|
Change type | SLM320 modem firmware update | |
Detailed description | SLM320 modem firmware has been improved for FMC130, FMC125, FMC230, FMC225 devices. | |
Old version:
V51_U07 |
New version:
V51_U09 | |
Change reasons |
| |
Product release date | July, 2023 |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes which support SLM320 modem | Updated SLM320 modem firmware |
Change impact | ||
---|---|---|
Risk assessment | During transition period clients might receive devices with previous SLM320 modem firmware version used in manufacture. | |
Suggested implementation plan | No implementation plan is needed. | |
Acknowledgement of PCN receipt | ||
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. |
2023.02.02: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from March 1st, 2023. New production firmware version will be 03.27.13.Rev.443
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: 03.27.13.Rev.54 |
New version: 03.27.13.Rev.443 | |
Change reasons | FMC130 base firmware version update for modifications with SLM320-LA module, SLM320-E1 module and SLM320-E2 module | |
Product release date | 2023 March |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* with 03.27.13.Rev.54 will be replaced to FMC130******* with base firmware | New firmware version |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2023.02.02: Changes in side frame for the battery placement
We would like to inform you that the side frame for the battery placement is included, helping to determine the exact location of the battery. Also, minor design changes are made to improve both case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices. The updates in the factory are being implemented in February, 2023.
Change description | ||
---|---|---|
Change type | Internal | |
Detailed description | The side frame for the battery placement is included, helping to determine the exact location of the battery. Also, minor design changes are made to improve both case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices. | |
Old Version: | New Version: | |
Change reasons | The battery placement is improved with a side frame, helping to determine the exact location of the battery. Minor design changes are made for case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices. | |
Product release date | February, 2023 |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, FMM150 | FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, FMM150 all codes | Updated the battery placement with the side frame as well as minor design changes for case production and assembly |
Change impact | ||
---|---|---|
Risk assessment | During the transition period clients might receive devices with old case design used in manufacture | |
Suggested implementation plan | Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process. |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. |
2022.11.16: SLM320 Modem Firmware Update
We would like to inform you, that SLM320 modem firmware has been updated for the FMC130 device and it is updated in factory from November, 2022.
Change description | ||
---|---|---|
Change type | SLM320 modem firmware update | |
Detailed description | SLM320 modem firmware has been improved for FMC130, FMC125, FMC230, FMC225 devices. | |
Old version: V51_U03 |
New version: V51_U07 | |
Change reasons | 1. Fixed issue with time synchronization 2. Resolved issue that module cannot connect to IP with end of .0 3. Resolved private APN issue to make TCP connection | |
Product release date | November, 2022 |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes which support SLM320 modem | Updated SLM320 modem firmware |
Change impact | ||
---|---|---|
Risk assessment | During transition period clients might receive devices with previous SLM320 modem firmware version used in manufacture. | |
Suggested implementation plan | No implementation plan is needed. | |
Acknowledgement of PCN receipt | ||
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. |
2022.10.01: Bluetooth® Improvement
We would like to inform you, that Bluetooth® performance for the FMC130 device will be updated in the factory from October, 2022.
Change description | ||
---|---|---|
Change type | Internal | |
Detailed description | BLE antenna has been improved FMC125, FMC225, FMC230 and FMC130 devices. | |
Old version: |
New version: | |
Change reasons | Bluetooth® antennas are improved for FMC125, FMC225, FMC230 and FMC130 devices ensuring better signal strength. | |
Product release date | October, 2022 |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FCM130 all codes | Updated BLE antenna |
Change impact | ||
---|---|---|
Risk assessment | No risk factors encountered with this change. | |
Suggested implementation plan | Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process. | |
Acknowledgement of PCN receipt | ||
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above. |
2022.03.18: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from March 18th, 2022. New production firmware version will be 03.27.13.Rev.54
Change description | ||
---|---|---|
Change type | Firmware update and order codes changes | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: FMC130 03.27.07.Rev.252 |
New version: FMC130 03.27.13.Rev.54 | |
Change reasons | FMC130 base firmware version update for modifications with SLM320-L module and SLM320-E2 module | |
Product release date | 2022 March |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC13064***** order will be replaced to FMC1304O**** with base firmware FMC1305X***** order will be replaced to FMC130KY**** with base firmware |
New firmware version |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2021.08.19: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from August 19th, 2021. New production firmware version will be 03.27.07.Rev.00
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: FMC130 03.27.04.Rev.01 |
New version: FMC130 03.27.07.Rev.00 | |
Change reasons | FMC130 base firmware version update | |
Product release date | 2021 August |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2021.03.16: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from March 16th, 2021. The new production firmware version will be 03.27.04.Rev.01.
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: FMC130 03.27.03.Rev.02 |
New version: FMC130 03.27.04.Rev.01 | |
Change reasons | FMC130 base firmware version update | |
Product release date | 2021 March 16th. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2021.02.18: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from February 18th, 2021. The new production firmware version will be 03.27.03.Rev.02.
Change description | ||
---|---|---|
Change type | Firmware update | |
Detailed description | Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata | |
Old version: FMC130 03.27.02.Rev.00 |
New version: FMC130 03.27.03.Rev.02 | |
Change reasons | FMC130 base firmware version update | |
Product release date | 2021 February 18th. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130******* order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2020.09.25: Base firmware update
We would like to inform you about the base firmware update for FMC130 starting from September 25th, 2020. The new production firmware version will be 03.27.02.Rev.01.
Change description | ||
---|---|---|
Change type | Firmware update. | |
Detailed description | Key improvements from last production firmware are listed in errata: FMC130 firmware errata | |
Old version:
FMC130 03.25.10.Rev.175 |
New version:
FMC130 03.27.02.Rev.01 | |
Change reasons | FMC130 base firmware version update for EMEA region. | |
Product release date | 2020 September 25th. |
Affected products | ||
---|---|---|
Model | Affected order codes | Order code changes |
FMC130 | FMC130C5**** order codes with base Firmware | Update firmware |
Change impact | ||
---|---|---|
Risk assessment | Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. | |
Suggested implementation plan | If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager. |
2019.11.28: Top Device Marking Changes
We would like to inform you, that tampography of the FMC130 device was updated to engraving in the factory.
Change description | ||
---|---|---|
Change type | External/visual | |
Detailed description | Device marking changed from tampography to laser printing. Information provided on module will remain the same | |
Old Version: |
New Version: | |
Change reasons | To improve manufacturing speed, efficiency and reliability
To increase quality, precision and durability of marking. | |
Product release date | Planned date: 2019 December |
Affected products | ||
---|---|---|
Model | all codes with standard marking | Order code changes |
FMC130 | FMC130******* | No changes |
Change impact | ||
---|---|---|
Risk assessment | No risk factors encountered with this change | |
Suggested implementation plan | No implementation plan needed |
Acknowledgement of PCN receipt | ||
---|---|---|
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above |