| Below is a detailed explanation of configurable parameters for each scenario. | | Below is a detailed explanation of configurable parameters for each scenario. |
| | | |
− | {| class="wikitable" style="text-align:center; width:100%;" | + | {| class="wikitable" style="text-align:left; width:100%;" |
− | ! Parameter ID !! Parameter Name !! Value Range !! Default Value !! Description | + | ! Parameter ID !! Parameter Name !! Min Value !! Max Value !! Default Value !! Description |
| |- | | |- |
− | | 19100, 19130, 19160 || Output Control || 0–3 || 0 || Determines which DOUT is controlled: | + | | 19100, 19130, 19160 || Output Control || 0 || 3 || 0 || Specifies the DOUT controlled by the scenario: |
| * 0 – None | | * 0 – None |
| * 1 – DOUT1 | | * 1 – DOUT1 |
Line 33: |
Line 33: |
| * 3 – DOUT3 | | * 3 – DOUT3 |
| |- | | |- |
− | | 19101, 19131, 19161 || Priority || 0–3 || 0 || Sets the priority level: | + | | 19101, 19131, 19161 || Priority || 0 || 3 || 0 || Sets the scenario priority: |
| * 0 – None | | * 0 – None |
| * 1 – Low | | * 1 – Low |
Line 39: |
Line 39: |
| * 3 – Panic | | * 3 – Panic |
| |- | | |- |
− | | 19124, 19154, 19184 || Permanent Output Control || 0–1 || 0 || Keeps the DOUT ON while the scenario is active, ignoring ON/OFF durations. | + | | 19124, 19154, 19184 || Permanent Output Control || 0 || 1 || 0 || Enables continuous DOUT control as long as conditions are met. |
| |- | | |- |
− | | 19102, 19132, 19162 || DOUT ON Duration || 100–65,000,000 ms || 200 ms || Defines the duration DOUT remains ON when activated. | + | | 19102, 19132, 19162 || DOUT ON Duration || 100 ms || 65,000,000 ms || 200 ms || Duration for which DOUT remains ON when the scenario is active. |
| |- | | |- |
− | | 19103, 19133, 19163 || DOUT OFF Duration || 0–65,000,000 ms || 200 ms || Defines the duration DOUT remains OFF for blinking behavior. | + | | 19103, 19133, 19163 || DOUT OFF Duration || 0 || 65,000,000 ms || 200 ms || Duration for which DOUT remains OFF. A value of 0 means the DOUT stays ON continuously. |
| |- | | |- |
− | | 19105, 19135, 19165 || Source || I/O Element ID || N/A || Specifies the I/O source to monitor (e.g., fuel level, ignition). | + | | 19105, 19135, 19165 || Source #1 || Device-specific || Device-specific || IO element ID || The primary I/O source for the trigger. Cannot be ignored. |
| |- | | |- |
− | | 19106, 19136, 19166 || Operand || 0–6 || 0 || Determines the evaluation logic for source values: | + | | 19110, 19140, 19170 || Source #2 || Device-specific || Device-specific || Ignored || The secondary I/O source. Can be ignored. |
| + | |- |
| + | | 19116, 19146, 19176 || Source #3 || Device-specific || Device-specific || Ignored || The tertiary I/O source. Can be ignored. |
| + | |- |
| + | | 19106, 19136, 19166 || Operand || 0 || 6 || 0 || Defines the condition logic for the trigger: |
| * 0 – On Exit | | * 0 – On Exit |
| * 1 – On Entrance | | * 1 – On Entrance |
Line 56: |
Line 60: |
| * 6 – Is | | * 6 – Is |
| |- | | |- |
− | | 19107, 19137, 19167 || Low Level || Dynamic || 0 || Sets the lower threshold for source trigger activation. | + | | 19107, 19137, 19167 || Low Level || Dynamic || Dynamic || 0 || Sets the lower threshold value for the source trigger. |
| |- | | |- |
− | | 19108, 19138, 19168 || High Level || Dynamic || 0 || Sets the upper threshold for source trigger activation. | + | | 19108, 19138, 19168 || High Level || Dynamic || Dynamic || 0 || Sets the upper threshold value for the source trigger. |
| |- | | |- |
− | | 19109, 19139, 19169 || Activation Delay Timer || 0–65,535 s || 0 || Time the condition must be true before the trigger activates. | + | | 19109, 19139, 19169 || Activation Delay Timer || 0 s || 65,535 s || 0 || Time (in seconds) the condition must remain true for activation. |
| |- | | |- |
− | | 19115, 19145, 19175 || Logic || 0–1 || 1 || Determines how triggers are evaluated: | + | | 19115, 19145, 19175 || Logic || 0 || 1 || 1 || Determines trigger evaluation logic: |
| * 0 – OR (any trigger activates the scenario) | | * 0 – OR (any trigger activates the scenario) |
− | * 1 – AND (all triggers must be true to activate) | + | * 1 – AND (all triggers must be true to activate the scenario) |
| |} | | |} |
| | | |
− | === Configuration Steps === | + | === Configuration Process === |
− | 1. **Define Output Control**: | + | |
− | - Select the DOUT to be controlled when the scenario is active. | + | 1. **Define Output Control**: |
− | 2. **Set Triggers**: | + | - Assign the DOUT (DOUT1, DOUT2, or DOUT3) to be controlled by the scenario. |
− | - Configure up to three sources, each with unique thresholds, operands, and delay timers. | + | |
− | - Sources must differ for each scenario. | + | 2. **Configure Triggers**: |
− | 3. **Configure Timing**:
| + | - Select up to three I/O sources (e.g., ignition, fuel level, temperature). |
− | - Set DOUT ON and OFF durations or enable Permanent Output Control for continuous activation. | + | - Define operands to specify logic (e.g., "On Entrance," "Is"). |
− | 4. **Save Settings**:
| + | - Set Low and High threshold values for each source. |
− | - Verify the configuration and save. The device evaluates all scenarios every second. | + | - Adjust the Activation Delay Timer for precise control. |
| + | |
| + | 3. **Set Priority**: |
| + | - Choose the priority level for the scenario. Higher-priority scenarios override lower-priority ones for the same DOUT. |
| + | |
| + | 4. **Adjust DOUT Control Settings**: |
| + | - Configure DOUT ON/OFF durations or enable Permanent Output Control for continuous activation. |
| + | |
| + | 5. **Save Configuration**: |
| + | - Verify all parameters and save the configuration. The device evaluates scenario conditions every second. |
| | | |
− | === Operational Details === | + | === Example Use Cases === |
− | - Scenarios are evaluated every second. When all triggers are true:
| |
− | - The scenario activates, toggling the DOUT and optionally creating a record.
| |
− | - Deep sleep compatibility: Scenarios operate in low-power modes if sources support it.
| |
− | - Priority management ensures higher-priority scenarios override lower-priority ones for DOUT control.
| |
| | | |
− | === Example Applications ===
| + | - **Scenario 1**: Control a relay when fuel level drops below 10%. |
− | - Activating an alarm if RPM exceeds a threshold while the ignition is on. | + | - **Scenario 2**: Trigger a buzzer if RPM exceeds 3000 while ignition is ON. |
− | - Triggering a relay when the fuel level drops below a critical point. | + | - **Scenario 3**: Activate an alarm when GSM signal strength drops below 20%. |
− | - Enabling a buzzer for temperature out-of-range conditions.
| |