Jump to content

Template:FMB Features settings: Difference between revisions

From Teltonika Telematics Wiki
Updating per 04 FW rewrite
No edit summary
 
(One intermediate revision by the same user not shown)
Line 72: Line 72:


Noise filter acceptance value is 50%, which means the shortest harsh driving event must last at least 500 ms. This filter generates only one record if harsh driving lasts longer than 1 second.
Noise filter acceptance value is 50%, which means the shortest harsh driving event must last at least 500 ms. This filter generates only one record if harsh driving lasts longer than 1 second.
===Advanced Eco Driving===
===Advanced Eco Driving===
Harsh driving event is detected when acceleration on a specific axis is above the configured threshold for the defined duration. Then, when acceleration on specific axis falls below the threshold for defined „event end duration, an eventual record is made as configured and an SMS message is sent (if configured).
Harsh driving event is detected when acceleration on a specific axis is above the configured threshold for the defined duration. Then, when acceleration on specific axis falls below the threshold for defined „event end duration, an eventual record is made as configured and an SMS message is sent (if configured).
Line 266: Line 265:


Authorized read notification feature allows the control of selected DOUT for a configured period, when '''Authorized ID''' is read using '''1-Wire, RFID Reader''' or when Authorized Beacon is detected. If Authorized ID List is empty or Beacon detection is set to All, then any detected ID or Beacon can control selected DOUT. Parameter '''Depend on Ignition''' allows to disable DOUT control, while Ignition is being detected. It is necessary to select at least one source for this functionality to work.
Authorized read notification feature allows the control of selected DOUT for a configured period, when '''Authorized ID''' is read using '''1-Wire, RFID Reader''' or when Authorized Beacon is detected. If Authorized ID List is empty or Beacon detection is set to All, then any detected ID or Beacon can control selected DOUT. Parameter '''Depend on Ignition''' allows to disable DOUT control, while Ignition is being detected. It is necessary to select at least one source for this functionality to work.
Authorized Read Notification parameters:
Authorized Read Notification parameters:
*'''Output Control''' – available scenario settings for module Digital output activation/deactivation
*'''Output Control''' – available scenario settings for module Digital output activation/deactivation

Latest revision as of 13:19, 28 May 2026