Difference between revisions of "Template:FM36 System Settings"
From Wiki Knowledge Base | Teltonika GPS
Simkunas.ma (talk | contribs) |
|||
(38 intermediate revisions by 2 users not shown) | |||
Line 10: | Line 10: | ||
**Digital Input (DIN1 ON – ignition on, DIN1 OFF – ignition off); | **Digital Input (DIN1 ON – ignition on, DIN1 OFF – ignition off); | ||
**Movement (if accelerometer/movement sensor detects movement then ignition is on, if movement stops – ignition is off). | **Movement (if accelerometer/movement sensor detects movement then ignition is on, if movement stops – ignition is off). | ||
− | |||
{| class="wikitable" | {| class="wikitable" | ||
Line 26: | Line 25: | ||
| style="text-align: left; vertical-align: top;" | Internal movement sensor detects movement | | style="text-align: left; vertical-align: top;" | Internal movement sensor detects movement | ||
|- | |- | ||
− | ! style="text-align: left; vertical-align: | + | ! style="text-align: left; vertical-align: top;" | GPS |
| style="text-align: left; vertical-align: top;" | GNSS fix is available and vehicle speed is lower than 5 km/h | | style="text-align: left; vertical-align: top;" | GNSS fix is available and vehicle speed is lower than 5 km/h | ||
| style="text-align: left; vertical-align: top;" | GNSS fix is available and vehicle speed is higher than 5 km/h | | style="text-align: left; vertical-align: top;" | GNSS fix is available and vehicle speed is higher than 5 km/h | ||
|- | |- | ||
− | + | |While GNSS fix is unavailable, Object Motion Detection Settings are working like in Msensor mode | |
|} | |} | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− |
Revision as of 12:29, 31 May 2018
System settings have 7 configurable parameters:
- Sleep settings, where user can turn GPS sleep/deep sleep on or off;
- Analog Input Settings, where user can choose analog input range 10 V or 30 V, depending on needed accuracy (lower range gives higher accuracy of measurements), and input voltage;
- Object Motion Detection Settings, where user can configure 3 ways how FM36YX will detect stopped movement, and change its working mode;
- Static navigation settings, where user can turn static navigation on or off;
- Records Settings, where user can enable or disable records when GPS is not available (no time synchronization);
- GNSS Settings, where user can choose satellite system and GNSS FIX Timeout Time (if after timeout there will not be synchronized time, it will be synchronized via NTP server);
- Ignition Source sets ignition triggered functionalities to be triggered by:
- Power Voltage (if voltage is between High Voltage Level and Low Voltage Level the ignition is considered to be turned on);
- Digital Input (DIN1 ON – ignition on, DIN1 OFF – ignition off);
- Movement (if accelerometer/movement sensor detects movement then ignition is on, if movement stops – ignition is off).
Stop Detection Source | Vehicle on Stop mode | Vehicle Moving mode |
---|---|---|
Ignition (recommended) | If ignition (configured Ignition Source) is logic low | If ignition (configured Ignition Source) is logic high |
Msensor (movement sensor) | Internal movement sensor does not detect movement | Internal movement sensor detects movement |
GPS | GNSS fix is available and vehicle speed is lower than 5 km/h | GNSS fix is available and vehicle speed is higher than 5 km/h |
While GNSS fix is unavailable, Object Motion Detection Settings are working like in Msensor mode |