Difference between revisions of "Template:FMB630 AutoCAN"
m (Text formatting) |
|||
(3 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | AutoCAN function allows user to automatically scan for available messages on CAN bus and configure CAN data sending to server. In order to configure AutoCAN connect | + | AutoCAN function allows user to automatically scan for available messages on CAN bus and configure CAN data sending to server. In order to configure AutoCAN connect {{model=FMB630}} to computer with Port ½ cable. Launch FMB630 configurator version 1.1.1.7 or higher. Push “Connect“ button, then „CAN“ button. CAN configuration menu will be opened. |
{{{image1|[[Image:FMB630_autoCAN1.png|center|200px]]}}} | {{{image1|[[Image:FMB630_autoCAN1.png|center|200px]]}}} | ||
− | * SCAN | + | * SCAN scans once for available messages on CAN bus; |
* Monitoring – toggles scanning of messages on CAN bus every 3 seconds; | * Monitoring – toggles scanning of messages on CAN bus every 3 seconds; | ||
− | * Offline Configuration – enables CAN configuration when | + | * Offline Configuration – enables CAN configuration when {{model=FMB630}} is not connected to CAN bus; |
* Auto CAN tab – configure CAN by selecting available messages from CAN bus; | * Auto CAN tab – configure CAN by selecting available messages from CAN bus; | ||
* Manual CAN tab – Configure CAN by manually entering CAN message ID and data mask; | * Manual CAN tab – Configure CAN by manually entering CAN message ID and data mask; | ||
Line 11: | Line 11: | ||
{{{image2|[[Image:FMB630_autoCAN2.png|center|250px]]}}} | {{{image2|[[Image:FMB630_autoCAN2.png|center|250px]]}}} | ||
− | To start CAN configuration push “SCAN“ button. A table of all available CAN messages will appear. Description of columns: | + | To start CAN configuration push “SCAN“ button. A table of all available CAN messages will appear (Figure 100). Description of columns: |
* Category – shows CAN message; | * Category – shows CAN message; | ||
* Parameter – shows configurable parameter name; | * Parameter – shows configurable parameter name; | ||
* Value – shows scanned value of parameter; | * Value – shows scanned value of parameter; | ||
* Send data to server – allows to choose the type of data when it‘s generated: | * Send data to server – allows to choose the type of data when it‘s generated: | ||
− | + | o Disabled – Data will not be collected | |
− | + | o On low priority – records will be generated as low priority events; | |
− | + | o On high priority – records will be generated as high priority events and immediately sent to server via GPRS (if GPRS is available); | |
− | + | o On panic - records will be generated as panic priority events and immediately sent to server via GPRS, if GPRS is not available records will be sent via SMS messages; | |
* Data acquisition type – allows to choose when records are generated: | * Data acquisition type – allows to choose when records are generated: | ||
− | + | oMonitoring – monitors data; | |
− | + | oOn change – record is generated when parameter value is changed; | |
− | + | oHysteresis – record is generated when increasing parameter value becomes higher than High value, and decreasing becomes less than Low value | |
− | + | oEvent on exit – record is generated when parameter value becomes higher than High value or lower than Low value; | |
− | + | oEvent on entrance – record is generated when parameter value becomes between High and Low values; | |
− | + | oEvent on both – record is generated when parameter value crosses High or Low values; | |
* Low – allows to choose low value for Data acquisition; | * Low – allows to choose low value for Data acquisition; | ||
* High – allows to choose High level for Data acquisition; | * High – allows to choose High level for Data acquisition; | ||
Line 40: | Line 40: | ||
Monitoring filters menu allows choosing which data will be shown in configuration menu. To enable/disable particular data monitoring use checkbox next to data name. To enable all data monitoring click Select all, to disable all data monitoring click Select none. | Monitoring filters menu allows choosing which data will be shown in configuration menu. To enable/disable particular data monitoring use checkbox next to data name. To enable all data monitoring click Select all, to disable all data monitoring click Select none. | ||
− | Note: CAN monitoring is | + | Note: CAN monitoring is {{model=FMB630}} configurator function; it does not enable data sending to server. In order to configure data sending to server refer to Configuration section. |
Revision as of 11:21, 1 June 2018
AutoCAN function allows user to automatically scan for available messages on CAN bus and configure CAN data sending to server. In order to configure AutoCAN connect Template:Model=FMB630 to computer with Port ½ cable. Launch FMB630 configurator version 1.1.1.7 or higher. Push “Connect“ button, then „CAN“ button. CAN configuration menu will be opened.
- SCAN scans once for available messages on CAN bus;
- Monitoring – toggles scanning of messages on CAN bus every 3 seconds;
- Offline Configuration – enables CAN configuration when Template:Model=FMB630 is not connected to CAN bus;
- Auto CAN tab – configure CAN by selecting available messages from CAN bus;
- Manual CAN tab – Configure CAN by manually entering CAN message ID and data mask;
To start CAN configuration push “SCAN“ button. A table of all available CAN messages will appear (Figure 100). Description of columns:
- Category – shows CAN message;
- Parameter – shows configurable parameter name;
- Value – shows scanned value of parameter;
- Send data to server – allows to choose the type of data when it‘s generated:
o Disabled – Data will not be collected o On low priority – records will be generated as low priority events; o On high priority – records will be generated as high priority events and immediately sent to server via GPRS (if GPRS is available); o On panic - records will be generated as panic priority events and immediately sent to server via GPRS, if GPRS is not available records will be sent via SMS messages;
- Data acquisition type – allows to choose when records are generated:
oMonitoring – monitors data; oOn change – record is generated when parameter value is changed; oHysteresis – record is generated when increasing parameter value becomes higher than High value, and decreasing becomes less than Low value oEvent on exit – record is generated when parameter value becomes higher than High value or lower than Low value; oEvent on entrance – record is generated when parameter value becomes between High and Low values; oEvent on both – record is generated when parameter value crosses High or Low values;
- Low – allows to choose low value for Data acquisition;
- High – allows to choose High level for Data acquisition;
CAN monitoring
To start CAN bus monitoring mark Monitoring check box. Table of available CAN messages will appear. Data from CAN bus will be updated every 3 seconds. In order to see only desired data open “Monitoring filters” menu.
Monitoring filters
Monitoring filters menu allows choosing which data will be shown in configuration menu. To enable/disable particular data monitoring use checkbox next to data name. To enable all data monitoring click Select all, to disable all data monitoring click Select none.
Note: CAN monitoring is Template:Model=FMB630 configurator function; it does not enable data sending to server. In order to configure data sending to server refer to Configuration section.