! style="text-align: left; vertical-align: top;" | Fuel sensor connection to {{{model|FM36YX}}}
 
! style="text-align: left; vertical-align: top;" | Fuel sensor connection to {{{model|FM36YX}}}
 
|-
 
|-
| style="text-align: left; vertical-align: top;" | A fuel tank level sensor exists in most cars, which shows the approximate fuel level in the driver’s indicator panel. It is possible to connect Analog input to {{{model|FM36YX}}} (if sensor returns analogue signal proportional to fuel level). Figure 10 shows the connection scheme to the {{{model|FM36YX}}} and fuel tank sensor through Analog input 1. After the connection to the tank fuel level sensor, calibration is needed. Calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage dependence on volume of fuel in tank.
+
| style="text-align: left; vertical-align: top;" | A fuel tank level sensor which indicates the approximate fuel level on the driver's indicator panel exists in most cars. If the sensor returns analogue signal proportional to fuel level it can be connected to {{{model|FM36YX}}} Analog input. After connection to the tank fuel level sensor a calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage values resulting from the volume of fuel in tank.
| style="text-align: left; vertical-align: top;" | [[Image:fuel sensor for FM36M1.png|250px|center]]
+
| style="text-align: left; vertical-align: top;" | [[Image:Sch_fmb1yx_lls.png|250px|center]]
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" | Alarm buttons, door sensors etc.
 
! style="text-align: left; vertical-align: top;" | Alarm buttons, door sensors etc.
Line 24: Line 24:
 
|-
 
|-
 
| style="text-align: left; vertical-align: top;" | Alarm buttons, door sensors, ignition, etc. have two output states: high or low. {{{model|FM36YX}}} Digital inputs are used to detect these states.
 
| style="text-align: left; vertical-align: top;" | Alarm buttons, door sensors, ignition, etc. have two output states: high or low. {{{model|FM36YX}}} Digital inputs are used to detect these states.
| style="text-align: left; vertical-align: top;" | [[Image:FM36M1_panic_buttont_connection.png|400px|center]]
+
| style="text-align: left; vertical-align: top;" | [[Image:Sch_fmb1yx_panic.png|400px|center]]
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" | Relays
 
! style="text-align: left; vertical-align: top;" | Relays
Line 30: Line 30:
 
|-
 
|-
 
| style="text-align: left; vertical-align: top;" | In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive.
 
| style="text-align: left; vertical-align: top;" | In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive.
| style="text-align: left; vertical-align: top;" | [[Image:inverting_relay_FM36.png|400px|center]]  
+
| style="text-align: left; vertical-align: top;" | [[Image:Sch_fmb1yx_inv_relay.png|400px|center]]  
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" | Immobilizer relay
 
! style="text-align: left; vertical-align: top;" | Immobilizer relay
Line 49: Line 49:
 
|-
 
|-
 
| style="text-align: left; vertical-align: top;" rowspan=5 | {{{oneWire|One of the implemented features on {{{model|FM36YX}}} is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A. }}}
 
| style="text-align: left; vertical-align: top;" rowspan=5 | {{{oneWire|One of the implemented features on {{{model|FM36YX}}} is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A. }}}
| style="text-align: left; vertical-align: top;" | {{{oneWire| {{{pic_ds1820|[[Image:DS1820_FM36M1.png|400px|center]]}}} }}}
+
| style="text-align: left; vertical-align: top;" | {{{oneWire| {{{pic_ds1820|[[Image:Sch_fmb120_ds1820.png|400px|center]]}}} }}}
 
|-  
 
|-  
 
| style="text-align: left; vertical-align: top;" | {{{oneWire| TTJ sensor pinout }}}
 
| style="text-align: left; vertical-align: top;" | {{{oneWire| TTJ sensor pinout }}}
 
|-
 
|-
| style="text-align: left; vertical-align: top;" | {{{oneWire| [[Image:Ttj_pinout_FM36.png|400px|center]] }}}
+
| style="text-align: left; vertical-align: top;" | {{{oneWire| [[Image:Ttj_pinout.png|400px|center]] }}}
 
|-
 
|-
 
! style="text-align: left; vertical-align: top;" | {{{oneWire| I-Button DS1990A connection to {{{model|FM36YX}}} }}}
 
! style="text-align: left; vertical-align: top;" | {{{oneWire| I-Button DS1990A connection to {{{model|FM36YX}}} }}}
 
|-
 
|-
| style="text-align: left; vertical-align: top;" | {{{oneWire| [[Image:Ibutton_FM36M1.png|400px|center]] }}}
+
| style="text-align: left; vertical-align: top;" | {{{oneWire| [[Image:Sch_fmb1yx_ibutton.png|400px|center]] }}}
 
|-
 
|-
 
|}
 
|}

Revision as of 07:36, 9 August 2018

Pages with broken file links > Template:FM36M1 Accessories
Bw nb.png Please order accessories separately as they are not included into device package.


Accessory and its description Accessory connection schematic
Fuel tank sensors Fuel sensor connection to FM36YX
A fuel tank level sensor which indicates the approximate fuel level on the driver's indicator panel exists in most cars. If the sensor returns analogue signal proportional to fuel level it can be connected to FM36YX Analog input. After connection to the tank fuel level sensor a calibration is needed because most fuel tank sensors are not linear. Calibration is performed by measuring voltage values resulting from the volume of fuel in tank.
Sch fmb1yx lls.png
Alarm buttons, door sensors etc. Panic button connection to FM36YX
Alarm buttons, door sensors, ignition, etc. have two output states: high or low. FM36YX Digital inputs are used to detect these states.
Sch fmb1yx panic.png
Relays Inverting relay connection to FM36YX
In cases when sensor output signal is negative, an additional relay has to be installed to convert negative signal to positive.
Sch fmb1yx inv relay.png
Immobilizer relay Immobilizer relay connection to FM36YX output
When connected as shown on the right hand side, FM36YX disables engine starter when output is ON.
Sch fmb1yx imb relay.png
Automotive relay Automotive relay pinout
An ordinary automotive relay is used to invert input signal or to immobilize engine starter. Note that relays can be 12 V or 24 V capable.
Pic relay.png
Sch ord relay.png
1-Wire devices Digital thermometer DS1820 and TTJ100 connection to FM36YX
One of the implemented features on FM36YX is 1-Wire® data protocol, which enables connection to devices such as thermometer (DS1820, DS18S20 and DS18B20) and I-Button DS1990A.
Sch fmb120 ds1820.png
TTJ sensor pinout
Ttj pinout.png
I-Button DS1990A connection to FM36YX
Sch fmb1yx ibutton.png