Difference between revisions of "FMA setdigout"

From Wiki Knowledge Base | Teltonika GPS
(One intermediate revision by the same user not shown)
Line 1: Line 1:
 
{{Template:FMB FW development notice}}
 
{{Template:FMB FW development notice}}
==<span>'''setdigout ## Y1 Y2:'''</span>==
 
  
 
Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row for OUT1 and OUT2 values.
 
Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row for OUT1 and OUT2 values.
Line 9: Line 8:
 
<br/><br/>
 
<br/><br/>
 
'''Example:'''<br/>"setdigout ?1" will set OUT2 to high level for indefinite period of time while OUT1 remains as it was set before.
 
'''Example:'''<br/>"setdigout ?1" will set OUT2 to high level for indefinite period of time while OUT1 remains as it was set before.
 
==<span>'''setdigout X Z Y:'''</span>==
 
 
Sets selected digital output to on or OFF state for a defined period of time.<br/>
 
'''Example:'''<br/>"setdigout2 1 5" will set DOUT2 to high level for 5 seconds.
 

Revision as of 15:12, 22 August 2018


Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row for OUT1 and OUT2 values.

Example:
"setdigout 01 0 5" will set OUT2 to high level for 5 seconds, while OUT1 to low level.

To ignore one digital output value and make ON/OFF state only to another digital output enter question mark.

Example:
"setdigout ?1" will set OUT2 to high level for indefinite period of time while OUT1 remains as it was set before.