+ | ==<span>'''setdigout ## Y1 Y2:'''</span>== | ||
Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row for OUT1 and OUT2 values. | Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row for OUT1 and OUT2 values. | ||
<br/><br/> | <br/><br/> | ||
− | Example:<br/>"setdigout 01 0 5" will set OUT2 to high level for 5 seconds, while OUT1 to low level. | + | '''Example:'''<br/>"setdigout 01 0 5" will set OUT2 to high level for 5 seconds, while OUT1 to low level. |
<br/><br/> | <br/><br/> | ||
To ignore one digital output value and make ON/OFF state only to another digital output enter question mark. | To ignore one digital output value and make ON/OFF state only to another digital output enter question mark. | ||
<br/><br/> | <br/><br/> | ||
− | Example:<br/>"setdigout ?1" will set OUT2 to high level for indefinite period of time while OUT1 remains as it was set before. | + | '''Example:'''<br/>"setdigout ?1" will set OUT2 to high level for indefinite period of time while OUT1 remains as it was set before. |
+ | |||
+ | ==<span>'''setdigout X Z Y:'''</span>== | ||
+ | |||
+ | Sets selected digital output to on or OFF state for a defined period of time.<br/> | ||
+ | '''Example:'''<br/>"setdigout2 1 5" will set DOUT2 to high level for 5 seconds. |
Latest revision as of 15:35, 22 August 2018
setdigout ## Y1 Y2:
Sets digital outputs to ON or OFF state (for some time if needed). Value is written as a row for OUT1 and OUT2 values.
Example:
"setdigout 01 0 5" will set OUT2 to high level for 5 seconds, while OUT1 to low level.
To ignore one digital output value and make ON/OFF state only to another digital output enter question mark.
Example:
"setdigout ?1" will set OUT2 to high level for indefinite period of time while OUT1 remains as it was set before.
setdigout X Z Y:
Sets selected digital output to on or OFF state for a defined period of time.
Example:
"setdigout2 1 5" will set DOUT2 to high level for 5 seconds.