Difference between revisions of "Template:FMM640 Authorized driving/Immobilizer"

From Wiki Knowledge Base | Teltonika GPS
(Created page with "==Authorized driving/Immobilizer== {{{pic_jamming|250px|right}}} *If DOUT Control is disabled, scenario will only generate events without di...")
Line 1: Line 1:
 
==Authorized driving/Immobilizer==
 
==Authorized driving/Immobilizer==
  
{{{pic_immobilizer|[[Image:FMB640_authorizedD.png|300px|right]]}}}
+
{{{pic_jamming|[[Image:FMB640_authorizedD.png|250px|right]]}}}
  
*If DOUT Control is disabled, the scenario will only generate events without digital output activation. If DOUT Control is enabled DOUT1/DOUT2 turns ON if ignition turns ON (Ignition Source is configured to 1).  
+
*If DOUT Control is disabled, scenario will only generate events without digital output activation. If DOUT Control is enabled DOUT1/DOUT2 turns ON if ignition turns ON (Ignition Source is configured to 1).  
 
* After any iButton ID is attached, DOUT1/DOUT2/DOUT3 turns OFF.  
 
* After any iButton ID is attached, DOUT1/DOUT2/DOUT3 turns OFF.  
* After iButton identification configured Ignition Source can be turned OFF (Ignition Source is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated.
+
* After iButton identification configured Ignition Source can be turned OFF (Ignition Source is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated. If * iButton List Check parameter is enabled, authorization will be successful only if the attached iButton is specified in iButton list. <br/>
* If iButton List Check parameter is enabled, the authorization will be successful only if the attached iButton is specified in the iButton list. <br/>
+
* Ignition off timeout parameter is used to set the duration after which authorization is activated, when ignition is turned off. <br/>
* Ignition off timeout parameter is used to set the duration after which authorization is activated when the ignition is turned off. <br/>
+
* Authorization off timeout parameter is used to set the duration how long the user has time to authorize after switching ignition on. <br/>
* Authorization off timeout parameter is used to set the duration of how long the user has time to authorize after switching the ignition ON. <br/>
+
* iButton list gives ability to use vehicle for 1000 specific iButton owners (specified in iButton list). Selected DOUT is controlled by scenario for user needs, to manage buzzer, LED etc.
* iButton list gives the ability to use the vehicle for 1000 specific iButton owners (specified in iButton list). Selected DOUT is controlled by scenario for user needs, to manage buzzer, LED, etc.
+
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
<!--
 
* Buzzer duration
 
New parameter implemented - Buzzer duration. Measured in minutes. <br>
 
After the ignition is turned ON, the configured immobilizer output control parameter turns ON (unless it's Disabled or configured as no DOUT control). DOUT can be deactivated by the iButton read from iButton1 or iButton2 readers or if the Buzzer duration parameter timeout occurs. Usage example: Driver or passenger enters the vehicle, turns the ignition ON (DIN1=1) and buzzer (DOUT2) is also turned ON. The buzzer will be ON as long as Buzzer Duration timeout occurs or until iButton will be successfully read.
 
* Passenger iButton
 
New IO element Passenger iButton added. <br>
 
New parameter Passenger iButton source implemented. Min: none (0); Max: DIN4 (4); Default: none (0). Parameter configuration id: 11714.
 
In order to distinguish driver and passenger iButtons while both iButton readers are on the same 1-wire line, special logic applied: if there is no voltage on configured Passenger iButton source DINX then it is taken that Passenger iButton is attached. The value of reading Passenger iButton ID is saved to Passenger iButton IO element. This functionality works with an immobilizer scenario only.
 
-->
 
{{{txt_br|<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>}}}
 

Revision as of 13:34, 22 August 2019

Authorized driving/Immobilizer

FMB640 authorizedD.png
  • If DOUT Control is disabled, scenario will only generate events without digital output activation. If DOUT Control is enabled DOUT1/DOUT2 turns ON if ignition turns ON (Ignition Source is configured to 1).
  • After any iButton ID is attached, DOUT1/DOUT2/DOUT3 turns OFF.
  • After iButton identification configured Ignition Source can be turned OFF (Ignition Source is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated. If * iButton List Check parameter is enabled, authorization will be successful only if the attached iButton is specified in iButton list.
  • Ignition off timeout parameter is used to set the duration after which authorization is activated, when ignition is turned off.
  • Authorization off timeout parameter is used to set the duration how long the user has time to authorize after switching ignition on.
  • iButton list gives ability to use vehicle for 1000 specific iButton owners (specified in iButton list). Selected DOUT is controlled by scenario for user needs, to manage buzzer, LED etc.