Difference between revisions of "Template:FM36 Electrical characteristics"

From Wiki Knowledge Base | Teltonika GPS
 
(No difference)

Latest revision as of 01:39, 28 February 2020

Electrical characteristics

Characteristic description Value
Min. Typ. Max. Unit
Supply Voltage:
Supply Voltage (Recommended Operating Conditions) 10 30 V
Digital Output (Open Drain grade):
Drain current (Digital Output OFF) 120 µA
Drain current (Digital Output ON, Recommended Operating Conditions) 0.1 0.5 A
Static Drain-Source resistance (Digital Output ON) 300
Digital Input:
Input resistance (DIN1) 15
Input resistance (DIN2, DIN3) 20
Input resistance (DIN4) 120
Input voltage (Recommended Operating Conditions) 0 Supply voltage V
Input Voltage threshold (DIN1) 7.5 V
Input Voltage threshold (DIN2, DIN3, DIN4) 2.5 V
Analog Input:
Input voltage (Recommended Operating Conditions), Range 1 0 10 V
Input resistance, Range 1 120
Measurement error 0.47 %
Additional error ±17.3 mV
Input Voltage (Recommended Operating Conditions), Range 2 0 30 V
Input resistance, Range 2 150
Measurement error 1.01 %
Additional error ±139 0 mV
Bw nb.png Analog Input error margin can increase if temperature varies.