Changes

Line 1: Line 1:  +
__TOC__
 +
 
{{Template:FMU Data acquisition settings|model=FMU126|ctrGsm=[[FMU126 GSM Operators settings|GSM Operators settings]]|ctrSystem=[[FMU126 System settings|System settings]]}}
 
{{Template:FMU Data acquisition settings|model=FMU126|ctrGsm=[[FMU126 GSM Operators settings|GSM Operators settings]]|ctrSystem=[[FMU126 System settings|System settings]]}}
 +
 +
==Panic Mode==
 +
 +
Panic mode was introduced from FW version FMB.Ver.03.27.01.Rev.160+.
 +
 +
This mode has 3 main parameters:
 +
* „min period"
 +
* „send period“
 +
*„activation source“
 +
 +
[[image:Panic_Mode.png]]
 +
 +
Parameters are located in the „Data acquisition“ tab. It works by checking the configured activation sources for events. If any one of them occurs, it changes the minimum acquisition period for records as well as starts to try to send records to the server at a different rate. When in panic mode, exiting is possible once all of the configured activation source exit conditions are met.
 +
 +
Sending to the server is tried every „send period“ parameter amount of seconds both to main and backup server. The selected activation source scenarios should be configured as not “none priority” in order for them to work.
 +
{| class="wikitable sortable"
 +
|+'''Table 1.''' Activation source enter/exit conditions
 +
! style="background: #0054A6; color:white" | '''Activation source'''
 +
! style="background: #0054A6; color:white" | '''Enter conditions'''
 +
! style="background: #0054A6; color:white" | '''Exit conditions'''
 +
|-
 +
|'''Unplug'''
 +
|Device unplugged based on Unplug scenario
 +
|External power connected
 +
|-
 +
|'''Towing'''
 +
|Towing occurred based on configuration
 +
|Towing is not active anymore (no movement for timeout  amount of time reached or ignition activated)
 +
|-
 +
|'''Autogeofence'''
 +
|Device exited autogeofence zone or no fix with the movement  for activation timeout amount of time
 +
|When deactivation source is triggered
 +
|}
 +
{| class="wikitable sortable"
 +
|+
 +
'''Table 2.''' Panic mode related parameters
 +
|style="background: #0054A6; color:white" | '''Parameter  name'''
 +
|style="background: #0054A6; color:white" | '''Min  value'''
 +
|style="background: #0054A6; color:white" | '''Max  value'''
 +
|style="background: #0054A6; color:white" | '''Default  value'''
 +
|style="background: #0054A6; color:white" | '''Parameter  ID'''
 +
| style="background: #0054A6; color:white"; colspan="2" |'''Description, possible values'''                                                                                                                               
 +
|-
 +
|'''Min period'''
 +
|0
 +
|65535
 +
|5
 +
|65801
 +
| colspan="2" |seconds
 +
|-
 +
|'''Send period'''
 +
|0
 +
|65535
 +
|10
 +
|65802
 +
| colspan="2" |seconds
 +
|-
 +
| rowspan="8" |'''Activation  source'''
 +
| rowspan="8" |0
 +
| rowspan="8" |7
 +
| rowspan="8" |0
 +
| rowspan="8" |65803
 +
|0
 +
|None
 +
|-
 +
|1
 +
|Unplug
 +
|-
 +
|2
 +
|Towing
 +
|-
 +
|3
 +
|Unplug +  Towing
 +
|-
 +
|4
 +
|Autogeofence
 +
|-
 +
|5
 +
|Autogeofence  + Unplug
 +
|-
 +
|6
 +
|Autogeofence  + Towing
 +
|-
 +
|7
 +
|Autogeofence  + Unplug + Towing
 +
|}
 
[[Category:FMU126 Configuration]]
 
[[Category:FMU126 Configuration]]

Navigation menu