| The digit 0 is used where no protection is provided. The digit is replaced with the letter X when insufficient data has been gathered to assign a protection level. Below is | | The digit 0 is used where no protection is provided. The digit is replaced with the letter X when insufficient data has been gathered to assign a protection level. Below is |
| + | |
| + | ==The First Digit: Solid particle protection== |
| | | |
| The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects. | | The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects. |
Line 13: |
Line 15: |
| |- | | |- |
| ! 0 | | ! 0 |
− | | — || No protection against contact and ingress of objects | + | | — || No protection against contact and ingress of objects. |
| |- | | |- |
| ! 1 | | ! 1 |
− | | >50 mm || Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part | + | | >50 mm || Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part. |
| |- | | |- |
| ! 2 | | ! 2 |
− | | >12.5 mm || Fingers or similar objects | + | | >12.5 mm || Fingers or similar objects. |
| |- | | |- |
| ! 3 | | ! 3 |
Line 32: |
Line 34: |
| ! 6 | | ! 6 |
| | Dust tight || No ingress of dust; complete protection against contact (dust tight). A vacuum must be applied. Test duration of up to 8 hours based on air flow. | | | Dust tight || No ingress of dust; complete protection against contact (dust tight). A vacuum must be applied. Test duration of up to 8 hours based on air flow. |
| + | |} |
| + | |
| + | ==The Second digit: Liquid ingress protection== |
| + | |
| + | The second digit indicates the level of protection that the enclosure provides against harmful ingress of water. |
| + | |
| + | {| class="wikitable" border=1 |
| + | ! Level || Protection against || Effective against || Details |
| + | |- |
| + | ! 0 | None || — || — |
| + | |- |
| + | ! 1 | >50 mm || Dripping water || Dripping water (vertically falling drops) shall have no harmful effect on the specimen when mounted in an upright position onto a turntable and rotated at 1 RPM. | Test duration: 10 minutes <br /> |
| + | Water equivalent to 1 mm rainfall per minute<br /> |
| + | |- |
| + | ! 2 | >12.5 mm || Dripping water when tilted at 15° || Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle of 15° from its normal position. A total of four positions are tested within two axes. || 2.5 minutes for every direction of tilt (10 minutes total) <br /> |
| + | Water equivalent to 3 mm rainfall per minute<br /> |
| + | |
| |} | | |} |