Changes

90 bytes added ,  14:54, 27 September 2021
m
no edit summary
Line 9: Line 9:  
Beacon are sent to server in a variable length Beacon IO '''(Teltonika data transfer ID 385)'''.  
 
Beacon are sent to server in a variable length Beacon IO '''(Teltonika data transfer ID 385)'''.  
   −
Beacon records are generated according to Beacon Record parameter. When Eventual mode is used, record is generated when BLE scan finishes. This mode does not work with '''non stop scan, as it never finishes scanning procedure'''. When Periodic mode is selected, beacon records are generated according to Period settings. When where is no visible beacons, empty beacon record will be generated.
+
Beacon records are generated according to Beacon Record parameter. When Eventual mode is used, record is generated when BLE scan finishes. This mode does not work with '''non stop scan, as it never finishes scanning procedure'''. When Periodic mode is selected, beacon records are generated according to Period settings. When there is no visible beacons, empty beacon record will be generated.
    
[[Image:Universal Beacon Simple.gif]]
 
[[Image:Universal Beacon Simple.gif]]
Line 24: Line 24:     
Beacon ID source can be selected.
 
Beacon ID source can be selected.
*When Beacon ID is used, source is used as configured in Beacon ID offset and Beacon ID size columns. When Beacon MAC address is selected, *Beacon ID will be replaced with MAC address. IO structure remains the same, but Beacon ID size will always be reported as 0x06.
+
*When Beacon ID is used, source is used as configured in Beacon ID offset and Beacon ID size columns.
 +
*When Beacon MAC address is selected, Beacon ID will be replaced with MAC address. IO structure remains the same, but Beacon ID size will always be reported as 0x06.
    
==Universal Beacons and Beacon On Change==
 
==Universal Beacons and Beacon On Change==
Line 32: Line 33:  
* On change mode - device will not create Beacon record after every scan procedure is completed unless scanned Beacon list will change.
 
* On change mode - device will not create Beacon record after every scan procedure is completed unless scanned Beacon list will change.
 
* Periodic - records will be saved according configuration settings.
 
* Periodic - records will be saved according configuration settings.
 +
[[Image:Universal Beacon On Change.gif]]
    
==Beacon Record Priority==
 
==Beacon Record Priority==
    
This selection defines what priority generated Beacon record will have, there is an exception for priority „None“ – if selected, no record will be generated. If value “Low” is selected, then Beacon record will be generated and sent once link with the server is established. If value “High” is selected, then Beacon record will be generated and sent immediately. This feature can be used with Beacon On Change or Periodic mode.
 
This selection defines what priority generated Beacon record will have, there is an exception for priority „None“ – if selected, no record will be generated. If value “Low” is selected, then Beacon record will be generated and sent once link with the server is established. If value “High” is selected, then Beacon record will be generated and sent immediately. This feature can be used with Beacon On Change or Periodic mode.
 +
 +
[[Image:Universal Beacon Records Priority.gif]]

Navigation menu