FMC640 Carrier: Difference between revisions

From Teltonika Telematics Wiki
(Created page with "==Introduction== Usually cargo is equally as important as the vehicle itself, with temperature data you can be assured that goods which you are delivering will maintain high q...")
 
No edit summary
 
(3 intermediate revisions by 3 users not shown)
Line 5: Line 5:


SUPPORTED CARRIER REFRIGERATORS: <br>
SUPPORTED CARRIER REFRIGERATORS: <br>
MAXIMA 1300  |  SUPRA 850  |  VECTOR 1800  |  VECTOR 1850  |  VECTOR 1850 MT  |  VECTOR 1550
VECTOR 1800  |  VECTOR 1850  |  VECTOR 1850 MT  |  VECTOR 1550


==Installation guide==
==Installation guide==


Installation manual for Carrier Vector 1550 can be downloaded here:
Installation manual for Carrier Vector 1550 can be downloaded here:
[[File:Download_zip.png|x30px|link=Special:Redirect/file/How_to_connect_FMB6_to_carrier_freezers.pdf]]
[[File:Download_zip.png|x30px|link=Special:Redirect/file/How_to_connect_tracker_to_Carrier_reefers_V1.5.pdf]]<br>
Installation requires [https://teltonika-gps.com/product/carrier-reefer-cable/#description "Carrier reefer cable"]


==Configuration==
==Configuration==


Make sure FM6 device is configured to receive data from “Carrier Freezer”. To do this, enter the configurator window, select RS232 \ RS485 section displayed in the screenshot below and configure accordingly (COM1 Settings, Mode “Carrier Freezer”, Baudrate: 9600)
Make sure FMC6 device is configured to receive data from “Carrier Reefer”. To do this, enter the configurator window, select RS232 \ RS485 section displayed in the screenshot below and configure accordingly (COM1 Settings, Mode “Carrier Reefer”, Baudrate: 9600)


[[image:Carrier.png|center]]
[[image:Reefer.png|center]]


The screenshot below displays Freezer I/O parameters section, here you can set up your device to send
The screenshot below displays Reefer I/O parameters section, here you can set up your device to send required parameters
required parameters.


[[image:Carrier2.png|center]]
[[image:Reefer IO.png|center]]
[[Category: FMC640 Manual]]
 
[[Codec#Codec_8_Extended | Codec 8 Extended]] should be selected as the main data protocol in the “Protocol Settings” tab, which is located in “System” section.
 
[[image:Reefer3.png|center]]
[[Category: FMC640 Manual| 2]]

Latest revision as of 16:36, 7 December 2021

Main Page > EOL Products > FMC640 > FMC640 Manual > FMC640 Carrier

Introduction

Usually cargo is equally as important as the vehicle itself, with temperature data you can be assured that goods which you are delivering will maintain high quality, thus Teltonika is offering ability to monitor real-time information from Carrier Freezers. The Carrier Control box/ecu is connected via RS232 port of the professional FMC6 trackers. The solution is easy to install and to configure. This allows to monitor the main information of the freezer trailer such as Temperature, Fridge door status, Alarms etc. and generate events according to your needs. For more information please refer to the installation manual below.

Supported Carrier Refrigerators

SUPPORTED CARRIER REFRIGERATORS:
VECTOR 1800 | VECTOR 1850 | VECTOR 1850 MT | VECTOR 1550

Installation guide

Installation manual for Carrier Vector 1550 can be downloaded here:
Installation requires "Carrier reefer cable"

Configuration

Make sure FMC6 device is configured to receive data from “Carrier Reefer”. To do this, enter the configurator window, select RS232 \ RS485 section displayed in the screenshot below and configure accordingly (COM1 Settings, Mode “Carrier Reefer”, Baudrate: 9600)

The screenshot below displays Reefer I/O parameters section, here you can set up your device to send required parameters

Codec 8 Extended should be selected as the main data protocol in the “Protocol Settings” tab, which is located in “System” section.