Difference between revisions of "Template:FMM130 Technical features"

From Wiki Knowledge Base | Teltonika GPS
 
(One intermediate revision by the same user not shown)
Line 68: Line 68:
 
         <tr>
 
         <tr>
 
         <td style="vertical-align:middle">Storage temperature (with battery)</td>
 
         <td style="vertical-align:middle">Storage temperature (with battery)</td>
         <td style="vertical-align:middle">5..95% (no condensation) </td>
+
         <td style="vertical-align:middle">0..+45 °C</td>
 
</tr>
 
</tr>
 
         <tr>
 
         <tr>
 
         <td style="vertical-align:middle">Operating humidity</td>
 
         <td style="vertical-align:middle">Operating humidity</td>
         <td style="vertical-align:middle">0..+45 °C</td>
+
         <td style="vertical-align:middle">5..95% (no condensation) </td>
 
     </tr>
 
     </tr>
 
         <tr>
 
         <tr>
Line 85: Line 85:
 
         <td style="vertical-align:middle">Battery discharge temperature</td>
 
         <td style="vertical-align:middle">Battery discharge temperature</td>
 
         <td>-20..+60 °C</td>
 
         <td>-20..+60 °C</td>
 +
</tr>
 +
        <tr>
 +
        <td style="vertical-align:middle">Internal fuse</td>
 +
        <td>3 A, 125 V</td>
 
     </tr>
 
     </tr>
 
         <tr>
 
         <tr>

Latest revision as of 15:52, 9 December 2021

Technical features


Part name Physical specification
Navigation indication LED
Modem indication LED
Socket Soldered inner socket
USB Micro USB socket
GNSS Internal GNSS antenna
GSM Internal GSM antenna



Technical details
2 W max.
Current consumption at 12 V (Power supply 6...30 V DC)
  • At 12V < 3 mA (Ultra Deep Sleep)
  • At 12V < 5 mA (Deep Sleep)
  • At 12V < 11 mA (Online Deep Sleep)
  • At 12V < 18 mA (GPS Sleep)
  • At 12V < 34 mA (nominal with no load)
  • At 12V < 2A Max. (with full Load / Peak)
Battery charge current Average 140 mA
Operating temperature (without battery) -20..+85 °C
Storage temperature (without battery) -20..+85 °C
Operating temperature (with battery) -20..+40 °C
Storage temperature (with battery) 0..+45 °C
Operating humidity 5..95% (no condensation)
Ingress Protection Rating IP41
Battery charge temperature 0..+45 °C
Battery discharge temperature -20..+60 °C
Internal fuse 3 A, 125 V
Device + case + battery weight 55 g


Dimension drawing:

FMB130 dimension.png