Line 53: Line 53:     
When vecicle speed exeeds configured max speed value scenario is activated, record will be generated and digital output status will be changed to 1 (if configured).<br/>Scenario is activated until current speed decreases below parameter value.
 
When vecicle speed exeeds configured max speed value scenario is activated, record will be generated and digital output status will be changed to 1 (if configured).<br/>Scenario is activated until current speed decreases below parameter value.
 
+
<br/><br/><br/><br/><br/><br/><br/><br/><br/>
<br/>
      
==Jamming==
 
==Jamming==
Line 61: Line 60:     
When jamming is detected scenario is activated, record will be generated and digital output status will be changed to 1 (if configured).<br/>Jamming timeout time can be configures. After Jamming trigger count configured timeout (in seconds), digital output control and jamming event will be generated after this timeout. If Jamming ends during timeout counting no event will be generated and output will not be controlled.<br/>You can configure eventual records parameter: when he is disabled scenario status value will be appeared in each AVL record, and when he is enabled scenario status value will be appended only to eventual records.
 
When jamming is detected scenario is activated, record will be generated and digital output status will be changed to 1 (if configured).<br/>Jamming timeout time can be configures. After Jamming trigger count configured timeout (in seconds), digital output control and jamming event will be generated after this timeout. If Jamming ends during timeout counting no event will be generated and output will not be controlled.<br/>You can configure eventual records parameter: when he is disabled scenario status value will be appeared in each AVL record, and when he is enabled scenario status value will be appended only to eventual records.
 +
<br/><br/><br/><br/><br/>
    
== DOUT Control Via Call==
 
== DOUT Control Via Call==
Line 71: Line 71:  
* DOUT1/DOUT2 can be turned off by Duration timeout (s) or by digital input 1, digital input 2 or digital input 3 (DOUT deactivation settings).
 
* DOUT1/DOUT2 can be turned off by Duration timeout (s) or by digital input 1, digital input 2 or digital input 3 (DOUT deactivation settings).
 
* DOUT1/DOUT2 can be turned off before Duration timeout (s) by selected DIN (DOUT deactivation settings).
 
* DOUT1/DOUT2 can be turned off before Duration timeout (s) by selected DIN (DOUT deactivation settings).
* DOUT1/DOUT2 always will be ON, if DOUT deactivation set to DIN1 for example,
+
* DOUT1/DOUT2 always will be ON, if DOUT deactivation set to DIN1 for example, but DIN1 will be never turned ON or set Duration timeout to Max value (2147483647) it is about 68 years.
but DIN1 will be never turned ON or set Duration timeout to Max value (2147483647) it is about 68 years.
      
==Immobilizer==
 
==Immobilizer==
Line 79: Line 78:     
If Dout Control is disabled, scenario will only generate events without digital output activation. If Dout Control is enabled DOUT1/DOUT2 (optional) turns ON if Ignition turns ON (configured Ignition Source =1). After iButton ID is read (any iButton is attached), DOUT1/DOUT2 turns OFF. After iButton identification, Ignition (configured Ignition Source) can be turned OFF (configured Ignition Source = 0) for no longer than 30 seconds3, otherwise immobilizer must be repeated. If iButton list checking parameter is enabled, authorization will be successful only if attached iButton is specified in the iButton list.
 
If Dout Control is disabled, scenario will only generate events without digital output activation. If Dout Control is enabled DOUT1/DOUT2 (optional) turns ON if Ignition turns ON (configured Ignition Source =1). After iButton ID is read (any iButton is attached), DOUT1/DOUT2 turns OFF. After iButton identification, Ignition (configured Ignition Source) can be turned OFF (configured Ignition Source = 0) for no longer than 30 seconds3, otherwise immobilizer must be repeated. If iButton list checking parameter is enabled, authorization will be successful only if attached iButton is specified in the iButton list.
 +
<br/><br/><br/><br/><br/><br/><br/><br/><br/>
    
==iButton Read Notification==
 
==iButton Read Notification==
Line 85: Line 85:     
This functionality allows user to see when iButton is being readed. Selected DOUT1 turns on for configured duration, after DOUT ON duration ends configured DOUT don’t turns on, even if iButton is left attached.
 
This functionality allows user to see when iButton is being readed. Selected DOUT1 turns on for configured duration, after DOUT ON duration ends configured DOUT don’t turns on, even if iButton is left attached.
 +
<br/><br/><br/><br/>
    
==GPS Fuel Counter==
 
==GPS Fuel Counter==