Difference between revisions of "Template:FMB125 Electrical characteristics"
From Wiki Knowledge Base | Teltonika GPS
(9 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
+ | ==Electrical characteristics== | ||
+ | <br> | ||
+ | <table class="nd-othertables" style="width: 72%;"> | ||
+ | <tr> | ||
+ | <th rowspan="2" style="width: 40%; text-align:center; vertical-align:middle; color:black">Characteristic description</th> | ||
+ | <th colspan="4" style="width: 32%; text-align:center; vertical-align:middle; color:black">Value</th> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="width: 8%; text-align:left"><b>Min.</b></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle"><b>Typ.</b></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle"><b>Max.</b></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle"><b>Unit</b></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td colspan="5" style="vertical-align:middle">Supply Voltage:</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Supply Voltage<br>(Recommended Operating Conditions)</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">+10</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">+30</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td colspan="5" style="vertical-align:middle">Digital Output (Open Drain grade):</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Drain current (Digital Output OFF)</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">120</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">µA</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Drain current<br>(Digital Output ON, Recommended Operating Conditions)</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">0.1</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">0.5</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">A</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Static Drain-Source resistance<br>(Digital Output ON)</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">400</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">600</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">mΩ</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td colspan="5" style="vertical-align:middle">Digital Input:</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Input resistance (DIN1)</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">47</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">kΩ</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Input voltage<br>(Recommended Operating Conditions)</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">0</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">Supply voltage</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Input Voltage threshold (DIN1)</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">7.5</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td colspan="5" style="vertical-align:middle">Analog Input:</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Input voltage<br>(Recommended Operating Conditions), Range 1</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">0</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">+10</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Input resistance, Range 1</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">150</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">kΩ</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Measurement error on 12V, Range 1</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">3</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">%</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Additional error on 12 V, Range 1</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">360</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">mV</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Measurement error on 30 V, Range 1</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">3</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">%</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Additional error on 30 V, Range 1</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">900</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">mV</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Input Voltage<br>(Recommended Operating Conditions), Range 2</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">0</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">+30</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Input resistance, Range 2</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">150</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">kΩ</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Measurement error on 12V, Range 2</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">3</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">%</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Additional error on 12 V, Range 2</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">360</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">mV</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Measurement error on 30 V, Range 2</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">3</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">%</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Additional error on 30 V, Range 2</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">900</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">mV</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td colspan="5" style="vertical-align:middle">Output Supply Voltage 1-Wire:</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Supply voltage</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">+4.5</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">+4.7</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Output inner resistance</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">7</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">Ω</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Output current (U<sub>out</sub> > 3.0 V)</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">30</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">mA</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">Short circuit current (U<sub>out</sub> = 0)</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">75</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">mA</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td colspan="5" style="vertical-align:middle">RS232/RS485 Input Voltage:</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">RS232 input voltage range (common-mode voltage)</td> | ||
+ | <td style="width: 8%; text-align:left">-15</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle"></td> | ||
+ | <td style="width: 8%; text-align:left">+15</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">RS485 input voltage range on A or B pin (common-mode voltage)</td> | ||
+ | <td style="width: 8%; text-align:left">-7</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle"></td> | ||
+ | <td style="width: 8%; text-align:left">+12</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br> | ||
+ | {| | ||
+ | |[[File:Alert.png|left|link=|50px]]||<b>Analog Input error margin can increase if temperature varies.</b> | ||
+ | |} | ||
+ | |||
==Absolute maximum ratings== | ==Absolute maximum ratings== | ||
− | + | <table class="nd-othertables" style="width: 72%;"> | |
− | + | <tr> | |
− | + | <th rowspan="2" style="width: 40%; text-align:center; vertical-align:middle; color:black">Characteristic description</th> | |
− | + | <th colspan="4" style="width: 32%; text-align:center; vertical-align:middle; color:black">Value</th> | |
− | + | </tr> | |
− | + | <tr> | |
− | + | <td style="width: 8%; text-align:left">Min.</td> | |
− | + | <td style="width: 8%; text-align:left"><b>Typ.</b></td> | |
− | + | <td style="width: 8%; text-align:left"><b>Max.</b></td> | |
− | + | <td style="width: 8%; text-align:left"><b>Unit</b></td> | |
− | + | </tr> | |
− | + | <tr> | |
− | + | <td style="text-align:left">Supply Voltage<br>(Absolute Maximum Ratings)</td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle">-32</td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle"></td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle">+32</td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | |
− | + | </tr> | |
− | + | <tr> | |
− | + | <td style="text-align:left">Drain-Source clamp threshold voltage<br>(Absolute Maximum Ratings), (I<sub>drain</sub> = 2 mA) </td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle"></td> | |
− | + | <td style="width: 8%; text-align:left"></td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle">+36</td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | |
− | + | </tr> | |
− | + | <tr> | |
− | + | <td style="text-align:left">Digital Input Voltage<br>(Absolute Maximum Ratings)</td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle">-32</td> | |
− | + | <td style="width: 8%; text-align:left"></td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle">+32</td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | |
− | + | </tr> | |
− | + | <tr> | |
− | + | <td style="text-align:left">Analog Input Voltage<br>(Absolute Maximum Ratings)</td> | |
− | + | <td style="width: 8%; text-align:left; vertical-align:middle">-32</td> | |
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">+32</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td style="text-align:left">RS232 Input Voltage<br>(Absolute Maximum Ratings)</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">-25</td> | ||
+ | <td style="width: 8%; text-align:left"></td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">+25</td> | ||
+ | <td style="width: 8%; text-align:left; vertical-align:middle">V</td> | ||
+ | </tr> | ||
+ | </table> |
Latest revision as of 15:14, 2 March 2022
Electrical characteristics
Characteristic description | Value | |||
---|---|---|---|---|
Min. | Typ. | Max. | Unit | |
Supply Voltage: | ||||
Supply Voltage (Recommended Operating Conditions) |
+10 | +30 | V | |
Digital Output (Open Drain grade): | ||||
Drain current (Digital Output OFF) | 120 | µA | ||
Drain current (Digital Output ON, Recommended Operating Conditions) |
0.1 | 0.5 | A | |
Static Drain-Source resistance (Digital Output ON) |
400 | 600 | mΩ | |
Digital Input: | ||||
Input resistance (DIN1) | 47 | kΩ | ||
Input voltage (Recommended Operating Conditions) |
0 | Supply voltage | V | |
Input Voltage threshold (DIN1) | 7.5 | V | ||
Analog Input: | ||||
Input voltage (Recommended Operating Conditions), Range 1 |
0 | +10 | V | |
Input resistance, Range 1 | 150 | kΩ | ||
Measurement error on 12V, Range 1 | 3 | % | ||
Additional error on 12 V, Range 1 | 360 | mV | ||
Measurement error on 30 V, Range 1 | 3 | % | ||
Additional error on 30 V, Range 1 | 900 | mV | ||
Input Voltage (Recommended Operating Conditions), Range 2 |
0 | +30 | V | |
Input resistance, Range 2 | 150 | kΩ | ||
Measurement error on 12V, Range 2 | 3 | % | ||
Additional error on 12 V, Range 2 | 360 | mV | ||
Measurement error on 30 V, Range 2 | 3 | % | ||
Additional error on 30 V, Range 2 | 900 | mV | ||
Output Supply Voltage 1-Wire: | ||||
Supply voltage | +4.5 | +4.7 | V | |
Output inner resistance | 7 | Ω | ||
Output current (Uout > 3.0 V) | 30 | mA | ||
Short circuit current (Uout = 0) | 75 | mA | ||
RS232/RS485 Input Voltage: | ||||
RS232 input voltage range (common-mode voltage) | -15 | +15 | V | |
RS485 input voltage range on A or B pin (common-mode voltage) | -7 | +12 | V |
Analog Input error margin can increase if temperature varies. |
Absolute maximum ratings
Characteristic description | Value | |||
---|---|---|---|---|
Min. | Typ. | Max. | Unit | |
Supply Voltage (Absolute Maximum Ratings) |
-32 | +32 | V | |
Drain-Source clamp threshold voltage (Absolute Maximum Ratings), (Idrain = 2 mA) |
+36 | V | ||
Digital Input Voltage (Absolute Maximum Ratings) |
-32 | +32 | V | |
Analog Input Voltage (Absolute Maximum Ratings) |
-32 | +32 | V | |
RS232 Input Voltage (Absolute Maximum Ratings) |
-25 | +25 | V |