Line 50: |
Line 50: |
| The second digit indicates the level of protection that the enclosure provides against harmful ingress of water. | | The second digit indicates the level of protection that the enclosure provides against harmful ingress of water. |
| | | |
− | {| class="wikitable" border=1 | + | {| class="wikitable" |
− | ! Level || Protection against || Effective against || Details | + | |+ |
| + | ! rowspan="1" style="width: 30px; background: #0054A6; color: white;" |'''Level''' |
| + | ! rowspan="1" style="width: 140px; background: #0054A6; color: white;" |'''Protection against''' |
| + | ! rowspan="1" style="width: 1000px; background: #0054A6; color: white;" |'''Effective against''' |
| + | ! rowspan="1" style="width: 330px; background: #0054A6; color: white;" |'''Details''' |
| |- | | |- |
− | ! 0
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |0 |
− | | None || — || — | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |None |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |— |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |— |
| |- | | |- |
− | ! 1
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |1 |
− | | Dripping water || Dripping water (vertically falling drops) shall have no harmful effect on the specimen when mounted in an upright position onto a turntable and rotated at 1 RPM. || Test duration: 10 minutes <br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Dripping water |
− | Water equivalent to 1 mm rainfall per minute<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Dripping water (vertically falling drops) shall have no harmful effect on the specimen when mounted in an upright position onto a turntable and rotated at 1 RPM. |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Test duration: 10 minutes |
| + | Water equivalent to 1 mm rainfall per minute |
| |- | | |- |
− | ! 2
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |2 |
− | | Dripping water when tilted at 15° || Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle of 15° from its normal position. A total of four positions are tested within two axes. || 2.5 minutes for every direction of tilt (10 minutes total) <br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Dripping water when tilted at 15° |
− | Water equivalent to 3 mm rainfall per minute<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle of 15° from its normal position. A total of four positions are tested within two axes. |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |2.5 minutes for every direction of tilt (10 minutes total) |
| + | Water equivalent to 3 mm rainfall per minute |
| |- | | |- |
− | ! 3
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |3 |
− | | Spraying water || Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield.<br />Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum. || For a Spray Nozzle:<br />Test duration: 1 minute per square meter for at least 5 minutes<br /> Water volume: 10 litres per minute<br /> Pressure: 50–150 kPa<br />For an oscillating tube:<br />Test duration: 10 minutes<br />Water Volume: 0.07 l/min per hole<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Spraying water |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Water falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield. |
| + | Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum. |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |For a Spray Nozzle: |
| + | Test duration: 1 minute per square meter for at least 5 minutes |
| + | Water volume: 10 litres per minute |
| + | Pressure: 50–150 kPa |
| + | For an oscillating tube: |
| + | Test duration: 10 minutes |
| + | Water Volume: 0.07 l/min per hole |
| |- | | |- |
− | ! 4
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |4 |
− | | Splashing of water || Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with no shield.<br />Test a) is conducted for 10 minutes. Test b) is conducted (without shield) for 5 minutes minimum. || Oscillating tube: Test duration: 10 minutes, or spray nozzle (same as IPX3 spray nozzle with the shield removed)<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Splashing of water |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with no shield. |
| + | Test a) is conducted for 10 minutes. Test b) is conducted (without shield) for 5 minutes minimum. |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Oscillating tube: Test duration: 10 minutes, or spray nozzle (same as IPX3 spray nozzle with the shield removed) |
| |- | | |- |
− | ! 5
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |5 |
− | | Water jets || Water projected by a nozzle (6.3 mm) against enclosure from any direction shall have no harmful effects. || Test duration: 1 minute per square meter for at least 15 minutes<br /> Water volume: 12.5 litres per minute Pressure: 30 kPa at distance of 3 m<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Water jets |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Water projected by a nozzle (6.3 mm) against enclosure from any direction shall have no harmful effects. |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Test duration: 1 minute per square meter for at least 15 minutes |
| + | Water volume: 12.5 litres per minute Pressure: 30 kPa at distance of 3 m |
| |- | | |- |
− | ! 6
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |6 |
− | | Powerful water jets || Water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects. || Test duration: 1 minute per square meter for at least 3 minutes<br />Water volume: 100 litres per minute<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Powerful water jets |
− | Pressure: 100 kPa at distance of 3 m<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Water projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects. |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Test duration: 1 minute per square meter for at least 3 minutes |
| + | Water volume: 100 litres per minute |
| + | Pressure: 100 kPa at distance of 3 m |
| |- | | |- |
− | ! 6K
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |6K |
− | | Powerful water jets with increased pressure || Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with no shield.<br />Test a) is conducted for 10 minutes. Test b) is conducted (without shield) for 5 minutes minimum. || Test duration: at least 3 minutes<br />Water volume: 75 litres per minute<br />Pressure: 1000 kPa at distance of 3 m<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Powerful water jets with increased pressure |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Water splashing against the enclosure from any direction shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with no shield. |
| + | Test a) is conducted for 10 minutes. Test b) is conducted (without shield) for 5 minutes minimum. |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Test duration: at least 3 minutes |
| + | Water volume: 75 litres per minute |
| + | Pressure: 1000 kPa at distance of 3 m |
| |- | | |- |
− | ! 7
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |7 |
− | | Immersion, up to 1 m depth || Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion). || Test duration: 30 minutes - ref IEC 60529, table 8.<br />Tested with the lowest point of the enclosure 1000 mm below the surface of the water, or the highest point 150 mm below the surface, whichever is deeper.<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Immersion, up to 1 m depth |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Ingress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion). |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Test duration: 30 minutes - ref IEC 60529, table 8. |
| + | Tested with the lowest point of the enclosure 1000 mm below the surface of the water, or the highest point 150 mm below the surface, whichever is deeper. |
| |- | | |- |
− | ! 8
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |8 |
− | | Immersion, 1 m or more depth || The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. The test depth and duration is expected to be greater than the requirements for IPx7, and other environmental effects may be added, such as temperature cycling before immersion || Test duration: Agreement with Manufacturer<br />Depth specified by manufacturer, generally up to 3 m<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Immersion, 1 m or more depth |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. The test depth and duration is expected to be greater than the requirements for IPx7, and other environmental effects may be added, such as temperature cycling before immersion |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Test duration: Agreement with Manufacturer |
| + | Depth specified by manufacturer, generally up to 3 m |
| |- | | |- |
− | ! 9K
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |9K |
− | | Powerful high temperature water jets || Protected against close-range high pressure, high temperature spray downs.<br />Smaller specimens rotate slowly on a turntable, from 4 specific angles. Larger specimens are mounted upright, no turntable required, and are tested freehand for at least 3 minutes at distance of 0.15–0.2 m.<br />There are specific requirements for the nozzle used for the testing.<br />This test is identified as IPx9 in IEC 60529. || Test duration: 30 seconds in each of 4 angles (2 minutes total)<br />Water volume: 14–16 litres per minute<br />Pressure: 8–10 MPa (80–100 bar) at distance of 0.10–0.15 m<br />Water temperature: 80 °C<br /> | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Powerful high temperature water jets |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Protected against close-range high pressure, high temperature spray downs. |
| + | Smaller specimens rotate slowly on a turntable, from 4 specific angles. Larger specimens are mounted upright, no turntable required, and are tested freehand for at least 3 minutes at distance of 0.15–0.2 m. |
| + | There are specific requirements for the nozzle used for the testing. |
| + | This test is identified as IPx9 in IEC 60529. |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Test duration: 30 seconds in each of 4 angles (2 minutes total) |
| + | Water volume: 14–16 litres per minute |
| + | Pressure: 8–10 MPa (80–100 bar) at distance of 0.10–0.15 m |
| + | Water temperature: 80 °C |
| |} | | |} |