Difference between revisions of "Template:FMX640 Short Burst Data"
m |
|||
(18 intermediate revisions by one other user not shown) | |||
Line 109: | Line 109: | ||
| 0 | | 0 | ||
| 1440 | | 1440 | ||
− | | | + | | 1440 |
| This parameter lets to configure Iridium Edge sending period | | This parameter lets to configure Iridium Edge sending period | ||
|- | |- | ||
Line 130: | Line 130: | ||
| 1 | | 1 | ||
| 5 | | 5 | ||
− | | | + | | 0 |
| Device DOUT which can control ON/OFF pin of the Iridium Edge | | Device DOUT which can control ON/OFF pin of the Iridium Edge | ||
|- | |- | ||
Line 143: | Line 143: | ||
<br></br> | <br></br> | ||
'''*''' SBD IO source parameter is configured with bitmasks (used for configuring I/O source elements via SMS/GPRS command) : | '''*''' SBD IO source parameter is configured with bitmasks (used for configuring I/O source elements via SMS/GPRS command) : | ||
− | * | + | *eSBD_IO_Bit_Disabled = 0x00, |
− | * | + | *eSBD_IO_Bit_Din1 = 0x01, |
− | * | + | *eSBD_IO_Bit_Din2 = 0x02, |
− | * | + | *eSBD_IO_Bit_Din3 = 0x04, |
− | * | + | *eSBD_IO_Bit_Din4 = 0x08, |
− | * | + | *eSBD_IO_Bit_Do1 = 0x10, |
− | * | + | *eSBD_IO_Bit_Do2 = 0x20, |
− | * | + | *eSBD_IO_Bit_Do3 = 0x40, |
− | * | + | *eSBD_IO_Bit_Do4 = 0x80, |
− | * | + | *eSBD_IO_Bit_Speed = 0x100 |
<br></br> | <br></br> | ||
− | For example: to enable Din1, Din3 and | + | For example: to enable Din1, Din3 and Do4: 0x01 + 0x04 + 0x80 = 0x85 convert to decimal --> 133. |
===Setting up Alarm priority records=== | ===Setting up Alarm priority records=== | ||
Line 266: | Line 266: | ||
==SBD packet example== | ==SBD packet example== | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− |
Revision as of 17:23, 14 November 2022
Introduction
Since 00.02.05 firmware version device supports Iridium devices - TSM-232 and Iridium Edge which can send short burst data (SBD) to the server. This means some data can be sent from the FM device to the server through satellites. From firmware version - 01.02.22.Rev.02, support for Iridium Edge is added. Iridium Edge features an all-in-one SBD module and antenna, with a power supply. The plug-and-play satellite IoT terminal can be easily paired with device in order to expand its functionality to no GSM coverage zones. Current Iridium implementation offers the ability to generate and send SBD records after a set period after the GSM signal is lost. This ensures constant connectivity as the Iridium network is available globally.
Connecting Iridium device to
In order to properly connect the Iridium device to , Iridium has to be connected to the device via RS-232 - COM1 or COM2 (with RJ-45 connector, where 4 pin is GND, 5 pin is RS232 Rx and 6 PIN is RS232 Tx). Additionally Pin No. 6 - power control (reference in the image below) must be connected to one of the DOUTs (1/2/3/4), in order to allow the device to power ON/OFF Iridium device on demand.
Iridium Edge pinout and RS232 COM 1/2 connection:
Pin. No |
Signal name |
Signal direction (with respect to Iridium Edge) |
Description |
---|---|---|---|
1 |
Spare |
- |
Unused |
2 |
Ground |
Input |
Signal and power GND |
3 |
RS232_RX |
Input |
RS232 input |
4 |
RS232_TX |
Output |
RS232 output |
5 |
Power |
Input |
9-32 V positive terminal |
6 |
ON/OFF |
Input |
Optional line to power down Iridium edge |
7 |
Network available |
Output |
|
8 |
Power Detection |
Output |
Active high then Iridium Edge is powered |
Configuring
In order to properly configure to get SBD records, first it is necessary to select correct RS232 mode in RS-232 / RS 485 TAB - “Satellite backup” mode must be selected in COM1/COM2 settings. Baudrate should be set to 19200.
Furthermore, in the Features TAB in Short burst data settings, TSM232 and Iridium Edge must be enabled. Power control DOUT configures DOUT pin which can control Iridium Edge ON/OFF pin. Configure if DOUT pin is connected. Respective power control DOUT to which Iridium device's PIN6 is connect must be selected.
Save/Send period configures how long will FMB device wait after losing the signal to generate SBD packet. If the signal is not recovered, it will send it indefinitely (or till the SBD Upload limit is reached, if such is set).
SBD Upload Limit is configurable and resets every month. This option can ensure that no additional data is used so that no unexpected costs are experienced by the customer. The default value is 8000 (for 8KB plan). This option can be disabled by setting the Upload limit to 0. The monthly data usage counter can be reset by using the SMS/GPRS command - sbdlimitsreset.
SBD IO source configures IO source which can trigger SBD record saving. 9 elements can generate Alarm for SDB sending. These elements are:
- Digital input 1
- Digital input 2
- Digital input 3
- Digital input 4
- Digital output 1
- Digital output 2
- Digital output 3
- Digital output 4
- Speed
Configurator parameter IDs and their explanation:
Parameter ID |
Parameter name | Values | Explanation | ||
---|---|---|---|---|---|
Min | Max | Default | |||
99420 | Iridium Edge | 0 | 1 | 0 | This parameter enables or disables Iridium Edge functionality |
99421 | Save/Send period | 0 | 1440 | 1440 | This parameter lets to configure Iridium Edge sending period |
99422 | SBD IO source* | 0 | 8 | 0 | SBD IO elements which when enabled are included into the SBD record |
99423 | SBD UploadLimit | 0 | 30000 | 8000 | Limit to save user from exceeding the monthly plan. Max limit of 30000 due to 30KB plan. If set to 0 – limit will be off. |
99424 | Power control DOUT | 1 | 5 | 0 | Device DOUT which can control ON/OFF pin of the Iridium Edge |
151 | RS232 Mode | 0 | 23 | 0 | RS-232 mode selection. "Satellite backup" - 15 |
* SBD IO source parameter is configured with bitmasks (used for configuring I/O source elements via SMS/GPRS command) :
- eSBD_IO_Bit_Disabled = 0x00,
- eSBD_IO_Bit_Din1 = 0x01,
- eSBD_IO_Bit_Din2 = 0x02,
- eSBD_IO_Bit_Din3 = 0x04,
- eSBD_IO_Bit_Din4 = 0x08,
- eSBD_IO_Bit_Do1 = 0x10,
- eSBD_IO_Bit_Do2 = 0x20,
- eSBD_IO_Bit_Do3 = 0x40,
- eSBD_IO_Bit_Do4 = 0x80,
- eSBD_IO_Bit_Speed = 0x100
For example: to enable Din1, Din3 and Do4: 0x01 + 0x04 + 0x80 = 0x85 convert to decimal --> 133.
Setting up Alarm priority records
In addition, you can select which IO element can generate Alarm priority record. The configurable IO parameters are listed as SBD IO source in list above. In order to do that you need to configure these IO elements as Panic priority. If properly configured SBD records are generated and sent if there is no GSM connection.
In the scenario shown in the above picture when panic record is made (generated by Digital Input 1 or Digital Input 2) internal 90 seconds timer will start to tick and if in that timeout device will not send the record through GPRS network it will be sent with Iridium satellites.
SDB record structure
SDB Record which will be sent through the Iridium satellites network will be different than the regular record. It will contain 4 bytes timestamp, 3 bytes longitude, 3 bytes latitude, 1 byte record generation info, 1 byte DIN,DOUT info, 1 byte Speed value.
Timestamp | Longitude | Latitude | SDB AVL ID and flags | DIN/DOUT info | Reserved | Speed |
---|---|---|---|---|---|---|
4B | 3B | 3B | 1B | 1B | 1B | 1B |
Timestamp - Indicates when record was generated.
Longitude - In this packet is encoded in 3 bytes data. The server that gets this data should divide the result from 46603,375 and subtract 180 to get the actual longitude value. This coefficient is got in the following way: 16777215(maximum 3 bytes value) divided by 360 (maximum longitude value then 180 is added). This calculation is used to fit negative and positive values to 3 bytes width variable.
Latitude - Is calculated in the same way as longitude but since latitude maximum value is two times smaller than longitude it can produce a bit more accurate data. The coefficient for latitude is 93206,75. This coefficient is got in the following way: 16777215(maximum 3 bytes value) divided by 180 (maximum latitude value then 90 is added). This calculation is used to fit negative and positive values to 3 bytes width variable.
SBD AVL ID and flags – Custom ID that will indicate what caused the record to be generated (final ID will (as only periodic records are generated, ID is not used)).
This byte is divided in two parts of four bits, as shown in table below:
Flags (not used yet) |
SBD AVL ID | ||||||
---|---|---|---|---|---|---|---|
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
SBD AVL ID is used to show which IO element generated the Panic element. The list of currently implemented possible values is described below:
ID |
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
---|---|---|---|---|---|---|---|---|---|---|
IO element |
Periodic rec. |
Digital Input 1 |
Digital input 2 |
Digital input 3 |
Digital input 4 |
Digital output 1 |
Digital output 2 |
Digital output 3 |
Digital output 4 |
Speed |
Data from Bit 7 to Bit 4 are not used at the moment. The server should ignore this data part.
DIN/DOUT info - Displays configured IO elements values of enabled IO elements in SBD IO source settings - (parameter ID 99422). Since digital inputs can contain only logic 1 or 0 they are bit masked in one byte.
DIN1 |
DIN2 |
DIN3 |
DIN4 |
DOUT1 |
DOUT2 |
DOUT3 |
DOUT4 |
---|---|---|---|---|---|---|---|
Bit 7 |
Bit 6 |
Bit 5 |
Bit 4 |
Bit 3 |
Bit 2 |
Bit 1 |
Bit 0 |
Reserved - Not used.
Speed – Indicates the speed of the vehicle if configured. If not (or in case of no GPS) – it will display 255.