Difference between revisions of "FMC225 Product Change Notifications"

From Wiki Knowledge Base | Teltonika GPS
(22 intermediate revisions by 6 users not shown)
Line 5: Line 5:
 
__TOC__
 
__TOC__
  
==2024.09.10: PCB changes==
 
We would like to inform you that starting from December, 2024, there will be changes in the PCB's modification of our FMC225 devices. These changes affect FMC125, FMC225, FMC130, FMC230 and FMC234 devices.
 
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
| style="text-align: left; background: white;" |Change type
 
| colspan="2" style="text-align: left; background: white;" |Mechanical part changes
 
|-
 
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |Change of mechanical components within PCB:
 
 
# The DOUT is derived from discrete components.
 
# No longer utilizes a dedicated part for the DOUT functionality.
 
# Features simple overvoltage protection for the RS485 interface.
 
# The microcontroller unit (MCU) has been upgraded from a Geehy MCU to an STM MCU.
 
 
|-
 
| style="text-align: left; background: white;" |Old version:<br><br>
 
 
[[File:PCB1.png|250px]]
 
 
[[File:PCB2.png|250px]]<br>
 
<br>
 
 
| style="text-align: left; background: white;" |New version:<br>
 
[[File:PCB3.png|250px]]<br>
 
 
[[File:PCB4.png|250px]]
 
|-
 
| style="text-align: left; background: white;" |Change reasons
 
| colspan="2" style="text-align: left; background: white;" |The PCB shape in the afore-mentioned devices is updated to streamline the manufacturing process, making it more efficient.
 
|-
 
| style="text-align: left; background: white;" | Product release date
 
| colspan="2" style="text-align: left; background: white;" | December, 2024
 
|-
 
|}
 
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Model
 
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
| style="text-align: left; background: white;" |FMC225
 
| style="text-align: left; background: white;" |FMC225******* order codes
 
| style="text-align: left; background: white;" |PCB's mechanical part changes
 
|-
 
|}
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 
| colspan="2" style="width: 908px; text-align: left; background: white;" | No risk factors encountered with this change.
 
|-
 
| style="text-align: left; background: white;" |Suggested implementation plan
 
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
 
|-
 
|}
 
 
{| class="wikitable"
 
|+
 
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 
|-
 
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
 
|-
 
|}
 
 
==2024.08.19: Base firmware update==
 
We would like to inform you about the base firmware update for FMC225 starting from September, 2024. New production firmware version will be '''03.29.00.Rev.21'''
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
| style="text-align: left; background: white;" |Change type
 
| colspan="2" style="text-align: left; background: white;" |Firmware update
 
|-
 
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: [[FMC225 firmware errata]]
 
|-
 
| style="text-align: left; background: white;" |Old version: <br> 03.29.00.Rev.18
 
| style="text-align: left; background: white;" |New version: <br> 03.29.00.Rev.21
 
|-
 
| style="text-align: left; background: white;" |Change reasons
 
| colspan="2" style="text-align: left; background: white;" |FMC225 base firmware version update
 
|-
 
| style="text-align: left; background: white;" | Product release date
 
| colspan="2" style="text-align: left; background: white;" |2024 September
 
|-
 
|}
 
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Model
 
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
| style="text-align: left; background: white;" |FMC225
 
| style="text-align: left; background: white;" |Order codes with base Firmware
 
| style="text-align: left; background: white;" |New firmware version
 
|-
 
|}
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 
|-
 
| style="text-align: left; background: white;" |Suggested implementation plan
 
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 
|-
 
|}
 
 
==2024 June: PCB changes==
 
We would like to inform you that starting from June, 2024, there will be changes in the PCB's modification of our FMC225 devices. These changes affect FMC125, FMC225, FMC130, FMC230 and FMC234 devices.
 
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
| style="text-align: left; background: white;" |Change type
 
| colspan="2" style="text-align: left; background: white;" |Mechanical part changes
 
|-
 
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |Change of mechanical components within PCB:
 
 
# U4100 changed to APM32F003F6U6
 
# Changed SWD pinout
 
# Added QR to BOT side
 
# Icreased TestPoint diameter
 
# Added TestPoint for reset pin(clearly visible)
 
# Removed modem USB TestPoint(clearly visible)
 
# Removed RF socket and cutout (Major change, clearly visible)
 
# Remade Palette just like in FMB1X0 project
 
# Discrete DOUT -> DOUT chip (clearly visible)
 
# Changed fuse to a smaller footprint (clearly visible)
 
|-
 
| style="text-align: left; background: white;" |Old version:<br><br>
 
 
[[File:C TOP -1.png|250px]]
 
 
[[File:C BOT -1.png|250px]]<br>
 
<br>
 
 
| style="text-align: left; background: white;" |New version:<br>
 
[[File:F TOP -3.png|250px]]<br>
 
 
[[File:F BOT -3.png|250px]]
 
|-
 
| style="text-align: left; background: white;" |Change reasons
 
| colspan="2" style="text-align: left; background: white;" |The PCB shape in the afore-mentioned devices is updated to streamline the manufacturing process, making it more efficient.
 
|-
 
| style="text-align: left; background: white;" | Product release date
 
| colspan="2" style="text-align: left; background: white;" |2024 June
 
|-
 
|}
 
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Model
 
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
| style="text-align: left; background: white;" |FMC225
 
| style="text-align: left; background: white;" |FMC225******* order codes
 
| style="text-align: left; background: white;" |PCB's mechanical part changes
 
|-
 
|}
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 
| colspan="2" style="width: 908px; text-align: left; background: white;" | No risk factors encountered with this change.
 
|-
 
| style="text-align: left; background: white;" |Suggested implementation plan
 
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
 
|-
 
|}
 
 
==2024.05.13: Base firmware update==
 
We would like to inform you about the base firmware update for FMC225 starting from June, 2024. New production firmware version will be '''03.29.00.Rev.18'''
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
| style="text-align: left; background: white;" |Change type
 
| colspan="2" style="text-align: left; background: white;" |Firmware update
 
|-
 
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: [[FMC225 firmware errata]]
 
|-
 
| style="text-align: left; background: white;" |Old version: <br> 03.29.00.Rev.13
 
| style="text-align: left; background: white;" |New version: <br> 03.29.00.Rev.18
 
|-
 
| style="text-align: left; background: white;" |Change reasons
 
| colspan="2" style="text-align: left; background: white;" |FMC225 base firmware version update
 
|-
 
| style="text-align: left; background: white;" | Product release date
 
| colspan="2" style="text-align: left; background: white;" |2024 June
 
|-
 
|}
 
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Model
 
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
| style="text-align: left; background: white;" |FMC225
 
| style="text-align: left; background: white;" |Order codes with base Firmware
 
| style="text-align: left; background: white;" |New firmware version
 
|-
 
|}
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 
|-
 
| style="text-align: left; background: white;" |Suggested implementation plan
 
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 
|-
 
|}
 
 
==2024.01.22: Modified battery placement within the casing==
 
We would like to inform you that starting from January 2024, there will be a small change in the FMC225 devices casing. We have adjusted the battery placement and increased PCB guide height within casing. This modification was essential to enhance our manufacturing process.
 
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
| style="text-align: left; background: white;" |Change type
 
| colspan="2" style="text-align: left; background: white;" |Optimizing robotic battery placement process within casing
 
|-
 
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |The modifications will not impact the place of the battery or PCB within the FMC225 device.
 
|-
 
| style="text-align: left; background: white;" |Old Version: [[File:FMX - OLD.jpg|center|250px]]                                                     
 
| style="text-align: left; background: white;" |New Version: [[File:FMX - NEW.jpg|center|250px]] [[File:FMX - NEW 2.jpg|center|250px]]                                                                                   
 
|-
 
| style="text-align: left; background: white;" |Change reasons
 
| colspan="2" style="text-align: left; background: white;" |
 
# Modified battery placement within the casing.
 
# PCB guide height increased for easier assembly.
 
# Improved manufacturing process.
 
|-
 
| style="text-align: left; background: white;" |Product release date
 
| colspan="2" style="text-align: left; background: white;" |January, 2024
 
|-
 
|}
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Model
 
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
| style="text-align: left; background: white;" |FMC225
 
| style="text-align: left; background: white;" |FMC225 all codes
 
| style="text-align: left; background: white;" | Modified battery placement and PCB guide height within the casing.
 
|-
 
|}
 
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |During transition period clients might receive devices with previous casing design. The transition period can last from January to February inclusive.
 
|-
 
| style="text-align: left; background: white;" |Suggested implementation plan
 
| colspan="2" style="text-align: left; background: white;" |No implementation plan is needed.
 
|-
 
|}
 
 
{| class="wikitable"
 
|+
 
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 
|-
 
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
 
|}
 
 
==2024.01.26: Base firmware update==
 
We would like to inform you about the base firmware update for FMC225 starting from January 26th, 2024. New production firmware version will be '''03.29.00.Rev.14'''
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
| style="text-align: left; background: white;" |Change type
 
| colspan="2" style="text-align: left; background: white;" |Firmware update
 
|-
 
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: [[FMC225_firmware_errata]]
 
|-
 
| style="text-align: left; background: white;" |Old version:
 
FMC225 03.27.13.Rev.443
 
| style="text-align: left; background: white;" |New version:
 
FMC225 03.29.00.Rev.14
 
|-
 
| style="text-align: left; background: white;" |Change reasons
 
| colspan="2" style="text-align: left; background: white;" |FMC2125 base firmware version update
 
|-
 
| style="text-align: left; background: white;" |Product release date
 
| colspan="2" style="text-align: left; background: white;" |2024 January
 
|-
 
|}
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Model
 
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
| style="text-align: left; background: white;" |FMC225
 
| style="text-align: left; background: white;" |FMC225******* order codes with base Firmware
 
| style="text-align: left; background: white;" |Update firmware
 
|-
 
|}
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 
|-
 
| style="text-align: left; background: white;" |Suggested implementation plan
 
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 
|-
 
|}
 
{| class="wikitable"
 
! colspan="3" style="text-align: left; background: white;" |Acknowledgement of PCN receipt
 
| colspan="1" style="width: 908px; text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 
|-
 
|}
 
 
==2023.07.01: SLM320 Modem Firware Update==
 
We would like to inform you, that SLM320 modem firmware has been updated for the FMC225 device and it is updated in factory from July, 2023.
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
| style="text-align: left; background: white;" |Change type
 
| colspan="2" style="text-align: left; background: white;" |SLM320 modem firmware update
 
|-
 
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |SLM320 modem firmware has been improved for FMC130, FMC125, FMC230, FMC225 devices.
 
|-
 
| style="text-align: left; background: white;" |Old version:
 
V51_U07
 
| style="text-align: left; background: white;" | New version:
 
V51_U09
 
|-
 
| style="text-align: left; background: white;" |Change reasons
 
| colspan="2" style="text-align: left; background: white;" |
 
#IMSI problem and special SIM card detection fixed
 
#IPv6 implementation
 
#General stability enhancements
 
|-
 
| style="text-align: left; background: white;" |Product release date
 
| colspan="2" style="text-align: left; background: white;" |July, 2023
 
|-
 
|}
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" |Affected products
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Model
 
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
| style="text-align: left; background: white;" |FMC225
 
| style="text-align: left; background: white;" |FMC225******* order codes which support SLM320 modem
 
| style="text-align: left; background: white;" |Updated SLM320 modem firmware
 
|-
 
|}
 
{| class="wikitable"
 
|+
 
! colspan="3" style="text-align: left; background: white;" | Change impact
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |During transition period clients might receive devices with previous SLM320 modem firmware version used in manufacture.
 
|-
 
| style="text-align: left; background: white;" | Suggested implementation plan
 
| colspan="2" style="text-align: left; background: white;" |No implementation plan is needed.
 
|-
 
! colspan="3" style="text-align: left; background: white;" |Acknowledgement of PCN receipt
 
|-
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
 
|-
 
|}
 
== 2023.03.14: Base firmware update ==
 
We would like to inform you about the base firmware update for FMC225 starting from March 14<sup>th</sup>, 2023. New production firmware version will be '''03.27.13.Rev.443.'''
 
{| class="wikitable"
 
! colspan="3" style="text-align: left; background: white;" |Change description
 
|-
 
| style="text-align: left; background: white;" |Change type
 
| colspan="2" style="text-align: left; background: white;" | Firmware update and order codes changes
 
|-
 
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC225_firmware_errata
 
|-
 
| style="text-align: left; background: white;" |Old version:
 
03.27.13.Rev.57
 
| style="text-align: left; background: white;" |New version:
 
03.27.13.Rev.443
 
|-
 
| style="text-align: left; background: white;" |Change reasons
 
| colspan="2" style="text-align: left; background: white;" |FMC225 base firmware version update for modifications with SLM320-LA module and SLM320-E2 module
 
|-
 
| style="text-align: left; background: white;" |Product release date
 
| colspan="2" style="text-align: left; background: white;" |2023 March
 
|}
 
{| class="wikitable"
 
! colspan="3" style="text-align: left; background: white;" | Affected products
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Model
 
| style="width: 448px; text-align: left; background: white;" | Affected order codes
 
| style="width: 448px; text-align: left; background: white;" |Order code changes
 
|-
 
| style="text-align: left; background: white;" | FMC125
 
| style="text-align: left; background: white;" |FMC225******* with 03.27.13.Rev.57 will be replaced to FMC225******* with base firmware
 
| style="text-align: left; background: white;" |New firmware version
 
|}
 
{| class="wikitable"
 
! colspan="3" style="text-align: left; background: white;" |Change impact
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client’s special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 
|-
 
| style="text-align: left; background: white;" |Suggested implementation plan
 
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 
|}
 
 
==2022.11.16: SLM320 Modem Firmware Update==
 
==2022.11.16: SLM320 Modem Firmware Update==
 
We would like to inform you, that SLM320 modem firmware has been updated for the FMC225 device and it is updated in factory from November, 2022.
 
We would like to inform you, that SLM320 modem firmware has been updated for the FMC225 device and it is updated in factory from November, 2022.
Line 507: Line 60:
  
  
==2022.10.01: Bluetooth® Improvement==
+
==2022.10.01: Bluetooth Improvement==
We would like to inform you, that Bluetooth® performance for the FMC225 device will be updated in the factory from October, 2022.
+
We would like to inform you, that Bluetooth performance for the FMC225 device will be updated in the factory from October, 2022.
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 524: Line 77:
 
|-
 
|-
 
| style="text-align: left; background: white;" |Change reasons
 
| style="text-align: left; background: white;" |Change reasons
| colspan="2" style="text-align: left; background: white;" |Bluetooth® antennas are improved for FMC125, FMC225, FMC230 and FMC130 devices ensuring better signal strength.
+
| colspan="2" style="text-align: left; background: white;" |Bluetooth antennas are improved for FMC125, FMC225, FMC230 and FMC130 devices ensuring better signal strength.
 
|-
 
|-
 
| style="text-align: left; background: white;" | Product release date
 
| style="text-align: left; background: white;" | Product release date

Revision as of 11:13, 17 November 2022

Main Page > Professional Trackers > FMC225 > FMC225 Product Change Notifications

Product change notifications (PCN) is the way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, firmware changes, changes to package contents, etc. This page stores information regarding changes to the FMC225 tracking device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).

2022.11.16: SLM320 Modem Firmware Update

We would like to inform you, that SLM320 modem firmware has been updated for the FMC225 device and it is updated in factory from November, 2022.

Change description
Change type SLM320 modem firmware update
Detailed description SLM320 modem firmware has been improved for FMC130, FMC125, FMC230, FMC225 devices.
Old version:
V51_U03
New version:
V51_U07
Change reasons 1. Fixed issue with time synchronization
2. Resolved issue that module cannot connect to IP with end of .0
3. Resolved private APN issue to make TCP connection
Product release date November, 2022
Affected products
Model Affected order codes Order code changes
FMC225 FMC225******* order codes which support SLM320 modem Updated SLM320 modem firmware
Change impact
Risk assessment During transition period clients might receive devices with previous SLM320 modem firmware version used in manufacture.
Suggested implementation plan No implementation plan is needed.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.


2022.10.01: Bluetooth Improvement

We would like to inform you, that Bluetooth performance for the FMC225 device will be updated in the factory from October, 2022.

Change description
Change type Internal
Detailed description BLE antenna has been improved FMC125, FMC225, FMC230 and FMC130 devices.
Old version:
FMC125old.png
FMC125old.1.png
New version:
FMC125new.png
FMC125new.1.png
Change reasons Bluetooth antennas are improved for FMC125, FMC225, FMC230 and FMC130 devices ensuring better signal strength.
Product release date October, 2022
Affected products
Model Affected order codes Order code changes
FMC225 FCM225 all codes Updated BLE antenna
Change impact
Risk assessment No risk factors encountered with this change.
Suggested implementation plan Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.