Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11200 | Uint16 | 0 | 0 | 3 | 0 – Disable | Scenario Settings |
1 – Low Priority | ||||||
2 – High Priority | ||||||
3 – Panic Priority | ||||||
11203 | Uint16 | 1 | 0 | 1 | 0 – Disable | Eventual Records |
1 – Enable | ||||||
11205 | Uint8 | 300 | 0 | 3600 | Seconds | Time to Stopped |
11206 | Uint8 | 5 | 0 | 3600 | Seconds | Time to Moving |
11204 | Uint16 | 0 | 0 | 2 | 0 – None | Output Control |
1 – DOUT1 | ||||||
2 – DOUT2 | ||||||
11201 | Uint8 | 200 | 100 | 5000 | Miliseconds | DOUT ON Duration |
11202 | Uint8 | 200 | 100 | 5000 | Miliseconds | DOUT OFF Duration |
7033 | Uint16 | "" | 0 | 10 | Predefined number | Send SMS to |
8033 | String | Idling Event | 0 | 160 | Char | SMS text |
Towing Detection
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11600 | Uint16 | 0 | 0 | 3 | 0 – Disable | Scenario Settings |
1 – Low Priority | ||||||
2 – High Priority | ||||||
3 – Panic Priority | ||||||
11601 | Uint16 | 1 | 0 | 1 | 0 – Disable | Eventual Records |
1 – Enable | ||||||
11602 | Uint8 | 5 | 0 | 65535 | Minutes | Activation Timeout |
11605 | Uint8 | 0,22 | 0,1 | 5 | Minutes | Event Timeout |
11602 | Uint8 | 5 | 0 | 65535 | g | Threshold |
11606 | Uint8 | 1 | 0,1 | 30 | Degrees | Angle |
11605 | Uint8 | 1000 | 1 | 5000 | Miliseconds | Duration |
11604 | Uint16 | "" | 0 | 10 | Predefined number | Make Call to |
7035 | Uint16 | "" | 0 | 10 | Predefined number | Send SMS to |
8035 | String | Towing | 0 | 160 | Char | SMS text |
Crash Detection
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11400 | Uint16 | 0 | 0 | 3 | 0 – Disable | Scenario Settings |
1 – Low Priority | ||||||
2 – High Priority | ||||||
3 – Panic Priority | ||||||
11401 | Uint8 | 5 | 0 | 1000 | Miliseconds | Duration |
11401 | Uint8 | 1500 | 100 | 6000 | mg | Threshold |
7037 | Uint16 | "" | 0 | 10 | Predefined number | Send SMS to |
8037 | String | Crash | 0 | 160 | Char | SMS text |
11412 | Uint16 | 0 | 0 | 1 | 0 – Disable | Trace Filter |
1 – Enable | ||||||
11406 | Uint16 | 0 | 0 | 2 | 0 – Disable | Crash Filter |
1 – Trace Changes | ||||||
2 – Trace Full | ||||||
11401 | Uint8 | 100 | 20 | 200 | Hz | Trace ODR |
11401 | Uint8 | 5 | 2 | 15 | Seconds | Accel Duration |