Changes

m
no edit summary
Line 37: Line 37:  
     </tr>
 
     </tr>
 
</table>
 
</table>
{{{pic_accelerometerposition|[[Image:FMB640accelerometerposition.png|300px|right]]}}} [[FMC640]] Device accelerometer position. (With positive Z axis pointing to Ground and antennas face forward in the vehicle). Before operation with the vehicle on level ground user must send “setacc” SMS.
      +
{{#switch: {{{model|}}}
 +
  | FMC640 = {{{pic_accelerometerposition|[[Image:fmx6_axis.jpg|300px|right]]}}} [[{{{model|FMC}}}]] Device accelerometer position. (With positive Z axis pointing to Ground and antennas face forward in the vehicle). Before operation with the vehicle on level ground user must send “setacc” SMS.
 +
 +
 +
  | FMM640 = {{{pic_accelerometerposition|[[Image:fmx6_axis.jpg|300px|right]]}}} [[{{{model|FMM}}}]] Device accelerometer position. (With positive Z axis pointing to Ground and antennas face forward in the vehicle). Before operation with the vehicle on level ground user must send “setacc” SMS.
 +
 +
 +
  | FMC650 = {{{pic_accelerometerposition|[[Image:fmx6_axis.jpg|300px|right]]}}} [[{{{model|FMC}}}]] Device accelerometer position. (With positive Z axis pointing to Ground and antennas face forward in the vehicle). Before operation with the vehicle on level ground user must send “setacc” SMS.
 +
 +
 +
  | FMM650 = {{{pic_accelerometerposition|[[Image:fmx6_axis.jpg|300px|right]]}}} [[{{{model|FMM}}}]] Device accelerometer position. (With positive Z axis pointing to Ground and antennas face forward in the vehicle). Before operation with the vehicle on level ground user must send “setacc” SMS.
 +
 +
 +
  | #default = {{{pic_accelerometerposition|[[Image:FMB640accelerometerposition.png|300px|right]]}}} [[{{{model|FMC}}}]] Device accelerometer position. (With positive Z axis pointing to Ground and antennas face forward in the vehicle). Before operation with the vehicle on level ground user must send “setacc” SMS.
 +
 +
}}
 
===Auto calibration===
 
===Auto calibration===
 
----
 
----
Line 44: Line 59:  
# The vehicle is stopped.
 
# The vehicle is stopped.
 
# There is a straight road ahead.
 
# There is a straight road ahead.
# Send SMS ''"auto_calibrate:set"'' to the {{{model_2|FMB}}} device.
+
# Send SMS ''"auto_calibrate:set"'' to the {{{model|FMB}}} device.
 
# Accelerate to >30 km/h for 5 sec.
 
# Accelerate to >30 km/h for 5 sec.
# {{{model_2|FMB}}} will send a response when calibration is completed successfully.
+
# {{{model|FMB}}} will send a response when calibration is completed successfully.
 
Calibration is saved to internal flash memory, which means it will stay after a reset.
 
Calibration is saved to internal flash memory, which means it will stay after a reset.
To check auto-calibration status send a following short text message to the {{{model_2|FMB}}} device: ''"auto_calibrate:get"''.
+
To check auto-calibration status send a following short text message to the {{{model|FMB}}} device: ''"auto_calibrate:get"''.
    
==Over Speeding==
 
==Over Speeding==
Line 72: Line 87:  
The scenario is activated and digital output is ON when a call is received from a number which is in authorized numbers list.
 
The scenario is activated and digital output is ON when a call is received from a number which is in authorized numbers list.
 
Call control functionality: <br/>
 
Call control functionality: <br/>
* When FMB64 is configured to control DOUT1/DOUT2/DOUT3/DOUT4 device waits for an incoming call from the configured secure number. If the call is received FMB64 turns on DOUT1/DOUT2/ DOUT3/DOUT4 for user-defined Duration timeout (s). If the Duration timeout set to „0“(s), DOUT1/DOUT2/ DOUT3/DOUT4 will be OFF. <br/>
+
* When {{{model|FMB}}} is configured to control DOUT1/DOUT2/DOUT3/DOUT4 device waits for an incoming call from the configured secure number. If the call is received {{{model|FMB}}} turns on DOUT1/DOUT2/ DOUT3/DOUT4 for user-defined Duration timeout (s). If the Duration timeout set to „0“(s), DOUT1/DOUT2/ DOUT3/DOUT4 will be OFF. <br/>
 
* DOUT1/ DOUT2/DOUT3/DOUT4 can be turned off by Duration timeout (s) or by digital input 1, digital input 2, digital input 3, or digital input 4 (DOUT deactivation settings). <br/>
 
* DOUT1/ DOUT2/DOUT3/DOUT4 can be turned off by Duration timeout (s) or by digital input 1, digital input 2, digital input 3, or digital input 4 (DOUT deactivation settings). <br/>
 
* DOUT1/DOUT2/DOUT3/DOUT4 can be turned off before Duration timeout (s) by selected DIN (DOUT deactivation settings).<br/>
 
* DOUT1/DOUT2/DOUT3/DOUT4 can be turned off before Duration timeout (s) by selected DIN (DOUT deactivation settings).<br/>
Line 136: Line 151:       −
'''''Save/Send period''''' configures how long will FMB device wait after losing the signal to generate SBD packet. If the signal is not recovered, it will send it indefinitely (or till the SBD Upload limit is reached, if such is set).
+
'''''Save/Send period''''' configures how long will {{{model|FMB}}} device wait after losing the signal to generate SBD packet. If the signal is not recovered, it will send it indefinitely (or till the SBD Upload limit is reached, if such is set).
    
'''''SBD Upload Limit''''' is configurable and resets every month. This option can ensure that no additional data is used so that no unexpected costs are experienced by the customer. The default value is 8000 (for 8KB plan). This option can be disabled by setting the Upload limit to 0. The monthly data usage counter can be reset by using the SMS/GPRS command - '''sbdlimitsreset'''.
 
'''''SBD Upload Limit''''' is configurable and resets every month. This option can ensure that no additional data is used so that no unexpected costs are experienced by the customer. The default value is 8000 (for 8KB plan). This option can be disabled by setting the Upload limit to 0. The monthly data usage counter can be reset by using the SMS/GPRS command - '''sbdlimitsreset'''.

Navigation menu