Changes

Line 68: Line 68:  
ELD functionality start to send data periodically via BT right after external BT device has been connected if OBD Feature (parameter ID 40000) is set to ELD (option 2). ELD data sending is paused if Configurator is connected. ELD data is resumed after configurator disconnects. ELD data sending resumes automatically when external BT device reconnects after connection loss.
 
ELD functionality start to send data periodically via BT right after external BT device has been connected if OBD Feature (parameter ID 40000) is set to ELD (option 2). ELD data sending is paused if Configurator is connected. ELD data is resumed after configurator disconnects. ELD data sending resumes automatically when external BT device reconnects after connection loss.
   −
===Parameters definitions===
+
===ELD J1939 Parameters definitions===
 +
 
 +
{| class="nd-othertables"
 +
|+
 +
! style="width:5%; text-align: center; vertical-align: middle;" | Parameter name
 +
! style="width:15%; text-align: center; vertical-align: middle;" | Parameter definition
 +
|-
 +
| style="text-align: center; vertical-align: middle;" | ''dashboard_mileage''
 +
| style="text-align: center; vertical-align: middle;" | Units in km, vehicle Total Distance PGN 65217 SPN 917
 +
|-
 +
| style="text-align: center; vertical-align: middle;" | ''obd_rpm''
 +
| style="text-align: center; vertical-align: middle;" | Vehicle RPM PGN 61444 SPN 19065217 SPN 917
 +
|-
 +
| style="text-align: center; vertical-align: middle;" |''obd_vin''
 +
| style="text-align: center; vertical-align: middle;" | Vehicle VIN PGN 65260 SPN 237
 +
|-
 +
| style="text-align: center; vertical-align: middle;" | ''ignition''
 +
| style="text-align: center; vertical-align: middle;" | Ignition state according to RPM, possible values: 0 – RPM=0 or 1– RPM>0
 +
|-
 +
| style="text-align: center; vertical-align: middle;" | ''loc''
 +
| style="text-align: center; vertical-align: middle;" | Current coordinates (longitude and latitude), example value "-10310092,3517679”, actual position is lon=-103.10092, lat=35.17679
 +
|-
 +
| style="text-align: center; vertical-align: middle;" | ''obd_speed''
 +
| style="text-align: center; vertical-align: middle;" | Units in km/h, wheel based speed PGN 65265 SPN 84
 +
|-
 +
| style="text-align: center; vertical-align: middle;" | ''engine_hours''
 +
| style="text-align: center; vertical-align: middle;" | Total Engine hours PGN 65253 SPN 247
 +
|-
 +
| style="text-align: center; vertical-align: middle;" | ''time''
 +
| style="text-align: center; vertical-align: middle;" | A point in time, defined as the number of seconds that have elapsed since 00:00:00 Coordinated Universal Time (UTC), Thursday, 1 January 1970. Current timestamp used in FM3001 record saving.
 +
|-
 +
| style="text-align: center; vertical-align: middle;" | ''Can_data''
 +
| style="text-align: center; vertical-align: middle;" | Shows whether CAN data is being read. 0 – CAN data is not being read; 1 – CAN data is being read.
 +
|}
 +
 
 +
<br>
 +
 
 +
{| class="wikitable" style="border-style: solid; border-width: 0px"
 +
|+
 +
|-
 +
| style="text-align: left; background: #F6F6FB;"        | [[Image:Bw_nb.png|50px]]
 +
| style="text-align: left; background: #F6F6FB;"        | Can_data parameter has been added from firmware version 03.18.00.
 +
|}