Changes

no edit summary
Line 30: Line 30:  
* Warm environment (+22°C) : <6.6 V<br>
 
* Warm environment (+22°C) : <6.6 V<br>
 
* Cold environment (+3°C) : <6.5 V<br>
 
* Cold environment (+3°C) : <6.5 V<br>
* Very cold environment (~-22°C) : <6.3 V<br>
+
* Very cold environment (-22°C) : <6.3 V<br>
<br>
+
 
 
{| class="main-table" style="background: #E7F1FE; color: black;"
 
{| class="main-table" style="background: #E7F1FE; color: black;"
 
{| style="width: 800px;height: 60px; text-align: left; border: 1 px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;"
 
{| style="width: 800px;height: 60px; text-align: left; border: 1 px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;"
Line 38: Line 38:  
These are examples and recommendations of the low battery alarm concept only. <br>Actual battery discharge curves may differ in various conditions.
 
These are examples and recommendations of the low battery alarm concept only. <br>Actual battery discharge curves may differ in various conditions.
 
|}
 
|}
<br>
+
 
 
===Low Voltage Record===
 
===Low Voltage Record===
 
To identify and get a dedicated record telling that the voltage threshold has been exceeded, follow below instructions. <br>
 
To identify and get a dedicated record telling that the voltage threshold has been exceeded, follow below instructions. <br>
Line 53: Line 53:  
<br>
 
<br>
 
Above can also be configured by sending an SMS/GPRS command to a device that has already been deployed in the field. <br>
 
Above can also be configured by sending an SMS/GPRS command to a device that has already been deployed in the field. <br>
<code>setparam 50120:1;50123:0;50122:6600;50124:1;50121:1</code><br><br>
+
<code>setparam 50120:1;50123:0;50122:6600;50124:1;50121:1</code><br>
 
{| class="main-table" style="background: #E7F1FE; color: black;"
 
{| class="main-table" style="background: #E7F1FE; color: black;"
 
{| style="width: 800px;height: 60px; text-align: left; border: 1 px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;"
 
{| style="width: 800px;height: 60px; text-align: left; border: 1 px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;"
Line 59: Line 59:  
|| '''Please note:'''<br>  
 
|| '''Please note:'''<br>  
 
Device will only receive SMS/GPRS command when it wakes up for periodic or scheduled record.  
 
Device will only receive SMS/GPRS command when it wakes up for periodic or scheduled record.  
|}<br><br>
+
|}<br>
 
Every time device wakes up to send a new record battery voltage is measured. If the battery voltage is lower than configured threshold (6.6 V in this example), an Event Record will be generated and sent to the server. This record will have event number <b>"67"</b> indicating low voltage. <br>
 
Every time device wakes up to send a new record battery voltage is measured. If the battery voltage is lower than configured threshold (6.6 V in this example), an Event Record will be generated and sent to the server. This record will have event number <b>"67"</b> indicating low voltage. <br>
 
Example record content:<br>
 
Example record content:<br>