Changes

Line 82: Line 82:  
From the version, 03.28.XX this new functionality includes new parameters:
 
From the version, 03.28.XX this new functionality includes new parameters:
   −
*'''Periodic Wakeup''' – if value is greater than zero, device while being in Deep Sleep or Online Deep Sleep, will wake up after defined period for beacon collection. This is mainly should be used when Bluetooth is disabled in sleep.
+
*'''Periodic Wakeup''' – if value is greater than zero, device while being in Deep Sleep or Online Deep Sleep, will wake up after defined period for beacon collection. This is mainly should be used when Bluetooth® is disabled in sleep.
*'''Bluetooth On While In Sleep'''- by default this parameter value is set to Enable and BT will work as in base functionality. If this value is set to Disable, Bluetooth will be turned off when device goes to Deep Sleep or Online Deep Sleep and will be turned on during Periodic Wakeup or if device enters normal state.
+
*'''Bluetooth® On While In Sleep'''- by default this parameter value is set to Enable and BT will work as in base functionality. If this value is set to Disable, Bluetooth® will be turned off when device goes to Deep Sleep or Online Deep Sleep and will be turned on during Periodic Wakeup or if device enters normal state.
 
[[Image:PWU.jpg|right|300px]]
 
[[Image:PWU.jpg|right|300px]]
 
</br></br>
 
</br></br>
   −
Note: In case when during scan after wakeup no BLE devices will be found FMB will be active for configured scan duration time in Bluetooth 4.0 tab. After that timeout FMB will go to sleep state.
+
Note: In case when during scan after wakeup no BLE devices will be found FMB will be active for configured scan duration time in Bluetooth® 4.0 tab. After that timeout FMB will go to sleep state.
 
<br>
 
<br>
   Line 103: Line 103:  
{{{ignition_source|Possible ignition sources:
 
{{{ignition_source|Possible ignition sources:
 
* '''Power Voltage''' - if voltage is between High Voltage Level and Low Voltage Level (below ''Ignition Settings'' options) - ignition is ON; if voltage is higher than High Voltage Level or lower than Low Voltage Level - ignition is OFF.
 
* '''Power Voltage''' - if voltage is between High Voltage Level and Low Voltage Level (below ''Ignition Settings'' options) - ignition is ON; if voltage is higher than High Voltage Level or lower than Low Voltage Level - ignition is OFF.
{{{txt_engine_rpm|* '''Engine RPM''' - if ''RPM'' from OBD II or CAN is higher than 0 - ignition is ON; if ''RPM'' from OBD II or CAN is equal to 0 - ignition is OFF;}}}
+
{{{txt_engine_rpm|* '''Engine RPM''' - if ''RPM'' from OBDII dongle is higher than 0 - ignition is ON; if ''RPM'' from OBD II or CAN is equal to 0 - ignition is OFF;}}}
 
* '''Accelerometer''' - if movement sensor detects movement - ignition is ON; if movement is not detected - ignition is OFF;
 
* '''Accelerometer''' - if movement sensor detects movement - ignition is ON; if movement is not detected - ignition is OFF;
 
More than one ignition source can be selected at the same moment. When there are 2 or more sources selected, at least one condition has to be met to change Ignition status.<br></br> }}}
 
More than one ignition source can be selected at the same moment. When there are 2 or more sources selected, at least one condition has to be met to change Ignition status.<br></br> }}}