Changes

Line 2: Line 2:  
| product_name  = FMB130 tracking device
 
| product_name  = FMB130 tracking device
 
}}
 
}}
 +
==2024.05.24: PCB changes==
 +
We would like to inform you that starting from June, 2024, there will be changes in the PCB's modification of our FMB130 devices. These changes affect FMB110, FMB120, FMB130 and FMB230 devices.
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Mechanical part changes
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |The PCB shape has been modified for the following devices: FMB110, FMB120, FMB130, and FMB230. These changes will be implemented during the upcoming factory update.
 +
|-
 +
| style="text-align: left; background: white;" |Old Version: [[File:OLD front.png|center|250px]] [[File:OLD back.png|center|250px]]                                                         
 +
| style="text-align: left; background: white;" |New Version: [[File:NEW front.png|center|250px]] [[File:NEW back.png|center|250px]]
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |
 +
#Components which were too close (less than 1.5mm) to the testpoints were moved away to comply with this requirement.
 +
#Overvoltage protection mosfet changed to 2x mosfets with smaller footprint.
 +
#Accelerometer LIS2DH12 was moved to top layer and closer to existing LIS3DH accelerometer.
 +
#Positioning hole was moved from LTE to BLE antenna.
 +
#Components from GNSS antenna feed point were moved away to comply with manufacturing requirements.
 +
#Main fuse moved to TOP layer.
 +
#Added 1 positioning hole close to GNSS antenna.
 +
#Positioning hole near LED's was removed.
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2024 June
 +
|-
 +
|}
   −
<!-- ==2022.11.01: Base firmware update==
+
{| class="wikitable"
We would like to inform you about the base firmware update for FMB130 starting from August 1st, 2022. New production firmware version will be 03.27.13.Rev.03
+
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB130
 +
| style="text-align: left; background: white;" |FMB130******* order codes
 +
| style="text-align: left; background: white;" |New firmware version
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
 
 +
==2024.05.13: Base firmware update==
 +
We would like to inform you about the base firmware update for FMB130 starting from June, 2024. New production firmware version will be '''03.29.00.Rev.18'''
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: [[FMB130 firmware errata]]
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> 03.29.00.Rev.13
 +
| style="text-align: left; background: white;" |New version: <br> 03.29.00.Rev.18
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMB130 base firmware version update
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2024 June
 +
|-
 +
|}
 +
 
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB130
 +
| style="text-align: left; background: white;" |Order codes with base Firmware
 +
| style="text-align: left; background: white;" |New firmware version
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
 
 +
 
 +
==2023.11.27: Modifications of PCB shape ==
 +
 
 +
We would like to inform you, that shape of the PCB (Printed Circuit Board) for the FMB110, FMB120, FMB130, and FMB230 devices will be altered as part of an upcoming factory update from November, 2023.
 +
 
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Internal
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |The PCB shape has been modified for the following devices: FMB110, FMB120, FMB130, and FMB230. These changes will be implemented during the upcoming factory update.
 +
|-
 +
| style="text-align: left; background: white;" |Old Version: [[File:51 TOP OLD.png|center|250px]] [[File:51 BOT OLD.png|center|250px]]                                                         
 +
| style="text-align: left; background: white;" |New Version: [[File:64 TOP NEW.png|center|250px]] [[File:64 BOT NEW.png|center|250px]]                                                                                   
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |
 +
#The cutout has been removed as it is intended only for devices with an external antenna.
 +
#Replaced electrolytic capacitors with ceramic capacitors in order to increase manufacturing efficiency. The modifications made do not have any impact on the functionality of the devices.
 +
|-
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |November, 2023
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB130
 +
| style="text-align: left; background: white;" |FMB130 all codes
 +
| style="text-align: left; background: white;" |
 +
#PCB cutout intended for an external antenna has been removed.
 +
#Replaced electrolytic capacitors with ceramic capacitors.
 +
|-
 +
|}
 +
 
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |No risk factors encountered with this change.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
 +
|-
 +
|}
 +
 
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
|-
 +
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
 +
|}
 +
 
 +
==2023.02.02: Changes in side frame for the battery placement==
 +
 
 +
We would like to inform you that the side frame for the battery placement is included, helping to determine the exact location of the battery. Also, minor design changes are made to improve both case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices. The updates in the factory are being implemented in February, 2023.
 +
 
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Internal
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |The side frame for the battery placement is included, helping to determine the exact location of the battery. Also, minor design changes are made to improve both case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices.
 +
|-
 +
| style="text-align: left; background: white;" |Old Version: [[File:Old 1.png|center|250px]] [[File:Old 2.png|center|250px]] [[File:Old 3.png|center|250px]]
 +
| style="text-align: left; background: white;" |New Version: [[File:New 1.png|center|250px]] [[File:New 2.png|center|250px]] [[File:New 3.png|center|250px]]
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |The battery placement is improved with a side frame, helping to determine the exact location of the battery. Minor design changes are made for case production and case assembly. These changes affect FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, and FMM150 devices.
 +
 
 +
|-
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |February, 2023
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, FMM150
 +
| style="text-align: left; background: white;" |FMB110, FMB120, FMB122, FMB125, FMC125, FMM125, FMB130, FMC130, FMM130, FMB140, FMB150, FMC150, FMM150 all codes
 +
| style="text-align: left; background: white;" |Updated the battery placement with the side frame as well as minor design changes for case production and assembly
 +
|-
 +
|}
 +
 
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |During the transition period clients might receive devices with old case design used in manufacture
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
 +
|-
 +
|}
 +
 
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
|-
 +
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
 +
|-
 +
|}
 +
 
 +
 
 +
==2022.11.01: Base firmware update and PCB design changes==
 +
We would like to inform you about the base firmware update for FMB130 starting from November 1st, 2022. New production firmware version will be 03.27.14.Rev.00
 
{| class="wikitable"
 
{| class="wikitable"
 
|+
 
|+
Line 51: Line 278:  
| style="text-align: left; background: white;" |Suggested implementation plan
 
| style="text-align: left; background: white;" |Suggested implementation plan
 
| colspan="2" style="text-align: left; background: white;" | 1. We highly recommend updating the spec.firmware`s with the latest version in order to support new changes on FMB130 hardware.  
 
| colspan="2" style="text-align: left; background: white;" | 1. We highly recommend updating the spec.firmware`s with the latest version in order to support new changes on FMB130 hardware.  
2. For further assistance, including the updates of special firmware versions, please contact your Teltonika Telematics sales manager or fill query on VIP HelpDesk.
+
2. For further assistance, including the updates of special firmware versions, please contact your Teltonika Telematics sales manager or fill query on HelpDesk.
 
|-
 
|-
 
|}
 
|}
-->
      
==2022.08.01: Base firmware update==
 
==2022.08.01: Base firmware update==
Line 194: Line 420:       −
==2021.04.30: Bluetooth Improvement==
+
==2021.04.30: Bluetooth® Improvement==
We would like to inform you, that Bluetooth performance for the FMB130 device will be updated in the factory from October 2021.
+
We would like to inform you, that Bluetooth® performance for the FMB130 device will be updated in the factory from October 2021.
 
{| class="wikitable"
 
{| class="wikitable"
 
! colspan="2" style="text-align: left; background: white;" |Change description
 
! colspan="2" style="text-align: left; background: white;" |Change description
Line 203: Line 429:  
|-
 
|-
 
| style="width: 221px; text-align: left; background: white;" |Detailed description
 
| style="width: 221px; text-align: left; background: white;" |Detailed description
| style="width: 908px; text-align: left; background: white;" |Bluetooth antennas are improved for FMB130 device ensuring better signal strength. The efficiency of Bluetooth antennas is considerably increased when receiving or transferring data.
+
| style="width: 908px; text-align: left; background: white;" |Bluetooth® antennas are improved for FMB130 device ensuring better signal strength. The efficiency of Bluetooth® antennas is considerably increased when receiving or transferring data.
 
|-
 
|-
 
|Change reasons
 
|Change reasons
| style="text-align: left; background: white;" | Following the changes, the capabilities of our devices will be greatly improved to provide better performance when Bluetooth signal is obstructed or longer distance coverage is required
+
| style="text-align: left; background: white;" | Following the changes, the capabilities of our devices will be greatly improved to provide better performance when Bluetooth® signal is obstructed or longer distance coverage is required
 
|-
 
|-
 
| style="text-align: left; background: white;" |Product release date
 
| style="text-align: left; background: white;" |Product release date
Line 583: Line 809:  
|}
 
|}
   −
To download the pdf version of this notification, [[Media: PCN_TM2500_20190614_EN.pdf|click here]].
+
To download the pdf version of this notification, [[Media:PCN TM2500 20190614 EN.pdf|click here]].
    
[[Category:FMB130]]
 
[[Category:FMB130]]