Changes

no edit summary
Line 2: Line 2:  
| product_name  = FMC130 tracking device
 
| product_name  = FMC130 tracking device
 
}}
 
}}
 +
 +
==2024 June: PCB changes==
 +
We would like to inform you that starting from June, 2024, there will be changes in the PCB's modification of our FMC130 devices. These changes affect FMC125, FMC225, FMC130, FMC230 and FMC234 devices.
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Mechanical part changes
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Change of mechanical components within PCB:
 +
 +
# U4100 changed to APM32F003F6U6
 +
# Changed SWD pinout
 +
# Added QR to BOT side
 +
# Icreased TestPoint diameter
 +
# Added TestPoint for reset pin(clearly visible)
 +
# Removed modem USB TestPoint(clearly visible)
 +
# Removed RF socket and cutout (Major change, clearly visible)
 +
# Remade Palette just like in FMB1X0 project
 +
# Discrete DOUT -> DOUT chip (clearly visible)
 +
# Changed fuse to a smaller footprint (clearly visible)
 +
|-
 +
| style="text-align: left; background: white;" |Old version:<br><br>
 +
 +
[[File:C TOP -1.png|250px]]
 +
 +
[[File:C BOT -1.png|250px]]<br>
 +
<br>
 +
 +
| style="text-align: left; background: white;" |New version:<br>
 +
[[File:F TOP -3.png|250px]]<br>
 +
 +
[[File:F BOT -3.png|250px]]
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |The PCB shape in the afore-mentioned devices is updated to streamline the manufacturing process, making it more efficient.
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2024 June
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMC130
 +
| style="text-align: left; background: white;" |FMC130******* order codes
 +
| style="text-align: left; background: white;" |PCB's mechanical part changes
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" | No risk factors encountered with this change.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
 +
|-
 +
|}
 +
==2024.05.13: Base firmware update==
 +
We would like to inform you about the base firmware update for FMC130 starting from June, 2024. New production firmware version will be '''03.29.00.Rev.18'''
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMC130_firmware_errata
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> 03.29.00.Rev.13
 +
| style="text-align: left; background: white;" |New version: <br> 03.29.00.Rev.18
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMC130 base firmware version update for modifications with SLM320-LA module, SLM320-E1 module and SLM320-E2 module
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2024 June
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMC130
 +
| style="text-align: left; background: white;" |
 +
* FMC1304O***** with 03.29.00.Rev.13 firmware
 +
* FMC130KY***** with 03.29.00.Rev.13 firmware
 +
* FMC130LK***** with 03.29.00.Rev.13 firmware
 +
* FMC130NQ***** with 03.29.00.Rev.13 firmware
 +
* FMC130QL***** with 03.29.00.Rev.13 firmware
 +
| style="text-align: left; background: white;" |New firmware version
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
 +
==2024.01.05: GNSS antenna changes==
 +
We would like to inform you that starting from February 2024, there will be a change in the manufacturing process of our FMC130 devices. We will be transitioning to utilize Surface Mount Device (SMD) manufactured GNSS antennas, which will replace the existing Dual-In-line Package (DIP) technique.
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" | Mechanical part changes
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Change of the manufacturing process, transition from Dual-In-line Package (DIP) to Surface Mount Device (SMD) process.
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> Dual-In-Line Package (DIP) manufactured antennas [[File:GNSS antenna Dual-In-Line Package (DIP) v1.png|center]]<br>
 +
Antenna size: 25x25x4 mm<br>
 +
Center frequency: 1575.42 MHz, 1602 MHz<br>
 +
VSWR: <1.1<br>
 +
Average Gain: -2.6 dB<br>
 +
Return loss: <-25 dB<br>
 +
| style="text-align: left; background: white;" |New version: <br> Surface Mount Device (SMD) manufactured antennas [[File:GNSS antenna DSurface Mount Device (SMD) v1.png|center]]<br>
 +
Antenna size: 25x25x4 mm<br>
 +
Center frequency 1575.42 MHz, 1602 MHz<br>
 +
VSWR: <1.9<br>
 +
Average Gain: -2.5 dB<br>
 +
Return loss: <-9 dB<br>
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" | Standardization of GNSS antennas throughout device portfolio and manufacturing efficiency improvements.<br>
 +
|-
 +
| style="text-align: left; background: white;" |Release date
 +
| colspan="2" style="text-align: left; background: white;" |February, 2024.
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMC130
 +
| style="text-align: left; background: white;" |FMC130******* order codes
 +
| style="text-align: left; background: white;" |SMD manufactured antennas
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" | During transition period clients might receive devices with previous DIP manufactured antennas. The transition period can last from February to June.
 +
 +
Since the change of the GNSS antenna is visible visually on PCB, in order to avoid problems at the customs of certain countries, we suggest informing the relevant authorities about the change of the GNSS antenna. The new SMD GNSS antenna provides an equivalent track quality and performance level, as verified through testing. Testing results:
 +
{| class="wikitable"
 +
|+ Caption text
 +
|-
 +
! '''Device''' !! '''Antenna''' !! '''Avg. Difference from precise track [m]*'''
 +
|-
 +
| FMC130_211|| SMD|| 3.30
 +
|-
 +
| FMC130_264|| SMD|| 2.94
 +
|-
 +
| FMC130_351|| SMD|| 2.65
 +
|-
 +
| FMC130_476|| DIP|| 4.23
 +
|-
 +
| FMC130_640|| DIP|| 3.52
 +
|}
 +
 +
* Avg. Difference from precise track - measured by comparing positioning data from devices and RTK (Real-time kinematic positioning) system data which is considered precise data. The smaller avg. difference from precise track, means better track quality.
 +
 +
** Testing is done inside vehicle interior. Devices were placed on the carpet, with front passenger seat removed. It is worth noting that GNSS signal is heavily influenced by the exact location device(s) is(are) placed.
 +
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |No implementation plan is needed.
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="width: 1141px; text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
|-
 +
| colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
 +
|-
 +
|}
 +
 
==2023.12.15: Base firmware update==
 
==2023.12.15: Base firmware update==
 
We would like to inform you about the base firmware update for FMC130 starting from December 15th, 2023. New production firmware version will be '''03.29.00.Rev.13'''
 
We would like to inform you about the base firmware update for FMC130 starting from December 15th, 2023. New production firmware version will be '''03.29.00.Rev.13'''
Line 49: Line 260:  
|-
 
|-
 
|}
 
|}
 +
 
==2023.12.01: Certification Engraving Update==
 
==2023.12.01: Certification Engraving Update==
  