Changes

Line 4: Line 4:  
__TOC__
 
__TOC__
    +
==2024 July: PCB changes==
 +
We would like to inform you that starting from July, 2024, there will be changes in the PCB's modification of our FMC125 devices. These changes affect FMC125, FMC225, FMC130, FMC230 and FMC234 devices.
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Mechanical part changes
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Change of mechanical components within PCB:
 +
 +
# U4100 changed to APM32F003F6U6
 +
# Changed SWD pinout
 +
# Added QR to BOT side
 +
# Icreased TestPoint diameter
 +
# Added TestPoint for reset pin(clearly visible)
 +
# Removed modem USB TestPoint(clearly visible)
 +
# Removed RF socket and cutout (Major change, clearly visible)
 +
# Remade Palette just like in FMB1X0 project
 +
# Discrete DOUT -> DOUT chip (clearly visible)
 +
# Changed fuse to a smaller footprint (clearly visible)
 +
|-
 +
| style="text-align: left; background: white;" |Old version:<br><br>
 +
 +
[[File:C TOP -1.png|250px]]
 +
 +
[[File:C BOT -1.png|250px]]<br>
 +
<br>
 +
 +
| style="text-align: left; background: white;" |New version:<br>
 +
[[File:F TOP -3.png|250px]]<br>
 +
 +
[[File:F BOT -3.png|250px]]
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |The PCB shape in the afore-mentioned devices is updated to streamline the manufacturing process, making it more efficient.
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2024 July
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMC125
 +
| style="text-align: left; background: white;" |FMC125******* order codes
 +
| style="text-align: left; background: white;" |PCB's mechanical part changes
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" | No risk factors encountered with this change.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
 +
|-
 +
|}
 +
 +
==2024.05.13: Base firmware update==
 +
We would like to inform you about the base firmware update for FMC125 starting from June, 2024. New production firmware version will be '''03.29.00.Rev.18'''
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: [[FMC125 firmware errata]]
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> 03.29.00.Rev.13
 +
| style="text-align: left; background: white;" |New version: <br> 03.29.00.Rev.18
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMC125 base firmware version update for modifications with SLM320-L16A module, SLM320-PE2H module
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2024 June
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMC125
 +
| style="text-align: left; background: white;" |
 +
* FMC12547***** with 03.29.00.Rev.13 firmware
 +
* FMC125TL***** with 03.29.00.Rev.13 firmware
 +
* FMC125FR***** with 03.29.00.Rev.13 firmware
 +
| style="text-align: left; background: white;" |New firmware version
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
 +
==2024.01.26: Base firmware update==
 +
We would like to inform you about the base firmware update for FMC125 starting from January 26th, 2024. New production firmware version will be '''03.29.00.Rev.14'''
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: [[FMC125_firmware_errata]]
 +
|-
 +
| style="text-align: left; background: white;" |Old version:
 +
FMC125 03.27.13.Rev.443
 +
| style="text-align: left; background: white;" |New version:
 +
FMC125 03.29.00.Rev.14
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |FMC125 base firmware version update
 +
|-
 +
| style="text-align: left; background: white;" |Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2024 January
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" |Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMC125
 +
| style="text-align: left; background: white;" |FMC125******* order codes with base Firmware
 +
| style="text-align: left; background: white;" |Update firmware
 +
|-
 +
|}
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" |If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
 +
|-
 +
|}
 +
{| class="wikitable"
 +
! colspan="3" style="text-align: left; background: white;" |Acknowledgement of PCN receipt
 +
| colspan="1" style="width: 908px; text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
 +
|-
 +
|}
 
== 2023.07.01: SLM320 Modem Firware Update ==
 
== 2023.07.01: SLM320 Modem Firware Update ==
 
We would like to inform you, that SLM320 modem firmware has been updated for the FMC125 device and it is updated in factory from July, 2023.
 
We would like to inform you, that SLM320 modem firmware has been updated for the FMC125 device and it is updated in factory from July, 2023.

Navigation menu