===Scenario settings===
 +
* '''Disable''' - disable scenario.
 +
* '''Low Priority''' - when low priority event is triggered, device '''makes additional record''' with indication of event cause.
 +
* '''High Priority''' - module makes additional record with High priority flag and '''sends event packet immediately''' to the server by
 +
'''GPRS'''.
 +
* '''Panic Priority''' - triggers same actions as High priority, but if '''GPRS fails''', it sends AVL packet using '''SMS mode''' if SMS is enabled in [[FMB965_SMS/Call_settings#SMS_Data_Sending|SMS Data Sending]] settings.
 +
 +
 +
* '''Angle''' - this parameter defines the angle that needs to be exceeded for fall detection to start counting Alarm Delay. The zero point angle (ground vector) is updated every time the device goes from movement state 1 to 0. It is also updated just before going to sleep.
 +
* '''Alarm Delay''' - this parameter sets time for how long the configured angle needs to be exceeded for the alarm event to trigger. The angle is checked every 1 second, so if during the alarm delay time the device is put back into vertical position (device angle is less than configured detection angle) the alarm delay resets.
 +
* '''Active Time''' - the scenario will stay active and scan for Alarm Delay start conditions for a configurable amount of time. If no Alarm Delay start is triggered during this time, the scenario stops working until the next sleep occurs. Zero angle will only be updated in this passive scenario state.