Difference between revisions of "Smart ignition"
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
+ | Smart Ignition detection is a functionality which detects ignition by sudden external voltage jumps instead of manually set High and Low voltage ranges. New configurable parameters were added under “Ignition Settings” (Figure 1): | ||
• Smart Ignition Enable/Disable – To enable functionality. Parameter is able to be configured if “Ignition Source” has “Power Voltage” configured. | • Smart Ignition Enable/Disable – To enable functionality. Parameter is able to be configured if “Ignition Source” has “Power Voltage” configured. | ||
− | |||
• Smart Ignition Delta (mV) – How much external voltage must change to detect ignition ON or OFF event. | • Smart Ignition Delta (mV) – How much external voltage must change to detect ignition ON or OFF event. | ||
− | |||
• Smart Ignition Duration (s) – Time interval used for comparing current external voltage against historical external voltage configured seconds ago. | • Smart Ignition Duration (s) – Time interval used for comparing current external voltage against historical external voltage configured seconds ago. | ||
− | [[File:Smart ignition.png|thumb | + | [[File:Smart ignition.png|thumb|alt=|left|Figure 1. “Smart Ignition” configurable parameters]] |
Line 41: | Line 17: | ||
− | + | “Smart Ignition Detection”– detects ignition “on” and “off” automatically by monitoring last “Smart Ignition Duration” seconds of external voltage and comparing it to current external voltage value. If current external voltage value is higher by “Smart Ignition Delta” than external voltage “Smart Ignition Duration” seconds ago, Ignition “on” event is detected. If current external voltage value is lower by “Smart Ignition Delta” than “Smart Ignition Duration” seconds ago Ignition “off” event is detected. | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− |
Revision as of 10:36, 10 July 2024
Smart Ignition detection is a functionality which detects ignition by sudden external voltage jumps instead of manually set High and Low voltage ranges. New configurable parameters were added under “Ignition Settings” (Figure 1): • Smart Ignition Enable/Disable – To enable functionality. Parameter is able to be configured if “Ignition Source” has “Power Voltage” configured. • Smart Ignition Delta (mV) – How much external voltage must change to detect ignition ON or OFF event. • Smart Ignition Duration (s) – Time interval used for comparing current external voltage against historical external voltage configured seconds ago.
“Smart Ignition Detection”– detects ignition “on” and “off” automatically by monitoring last “Smart Ignition Duration” seconds of external voltage and comparing it to current external voltage value. If current external voltage value is higher by “Smart Ignition Delta” than external voltage “Smart Ignition Duration” seconds ago, Ignition “on” event is detected. If current external voltage value is lower by “Smart Ignition Delta” than “Smart Ignition Duration” seconds ago Ignition “off” event is detected.