Template:Teltonika FTXXX1 Data Sending Parameters ID: Difference between revisions
(3 intermediate revisions by one other user not shown) | |||
Line 382: | Line 382: | ||
| style="vertical-align: middle; text-align: center;" |205 | | style="vertical-align: middle; text-align: center;" |205 | ||
| style="vertical-align: middle; text-align: center;" |GSM Cell ID | | style="vertical-align: middle; text-align: center;" |GSM Cell ID | ||
| style="vertical-align: middle; text-align: center;" | | | style="vertical-align: middle; text-align: center;" |4 | ||
| style="vertical-align: middle; text-align: center;" |Unsigned | | style="vertical-align: middle; text-align: center;" |Unsigned | ||
| style="vertical-align: middle; text-align: center;" |0 | | style="vertical-align: middle; text-align: center;" |0 | ||
| style="vertical-align: middle; text-align: center;" | | | style="vertical-align: middle; text-align: center;" |2147483647 | ||
| style="vertical-align: middle; text-align: center;" | - | | style="vertical-align: middle; text-align: center;" | - | ||
| style="vertical-align: middle; text-align: center;" | - | | style="vertical-align: middle; text-align: center;" | - | ||
Line 580: | Line 580: | ||
| style="vertical-align: middle;" | | | style="vertical-align: middle;" | | ||
Value of SIM ICCID | Value of SIM ICCID | ||
| style="vertical-align: middle; text-align: center;" | | |||
<div class="mw-customtoggle-" style="margin:0 auto; vertical-align: middle; text-align: center; overflow:auto;"> | |||
FTXXXX | |||
<span class="mw-collapsible mw-collapsed">{{Template:FTXXXX HW}}</span> | |||
</div> | |||
| style="vertical-align: middle; text-align: center;" |Permanent I/O elements | |||
|- | |||
| style="vertical-align: middle; text-align: center;" |70 | |||
| style="vertical-align: middle; text-align: center;" |PCB temperature | |||
| style="vertical-align: middle; text-align: center;" |2 | |||
| style="vertical-align: middle; text-align: center;" |Signed | |||
| style="vertical-align: middle; text-align: center;" |-550 | |||
| style="vertical-align: middle; text-align: center;" |1150 | |||
| style="vertical-align: middle; text-align: center;" |0,1 | |||
| style="vertical-align: middle; text-align: center;" |°C | |||
| style="vertical-align: middle;" | | |||
Degrees ( °C ) | |||
| style="vertical-align: middle; text-align: center;" | | | style="vertical-align: middle; text-align: center;" | | ||
<div class="mw-customtoggle-" style="margin:0 auto; vertical-align: middle; text-align: center; overflow:auto;"> | <div class="mw-customtoggle-" style="margin:0 auto; vertical-align: middle; text-align: center; overflow:auto;"> |
Latest revision as of 15:16, 16 December 2024
FTC AVL ID's consist of these parameters groups:
Permanent I/O elements
style="vertical-align: middle; text-align: center;"
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
239 | Ignition | 1 | Unsigned | 0 | 1 | - | - |
0 – Ignition Off |
Permanent I/O Elements | |
240 | Movement | 1 | Unsigned | 0 | 1 | - | - |
0 – Movement Off |
Permanent I/O Elements | |
303 | Instant Movement | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 returns movement value | Permanent I/O elements | |
21 | GSM Signal | 1 | Unsigned | 0 | 5 | - | - |
Value in range 1-5 |
Permanent I/O Elements | |
800 | External Voltage | 4 | Unsigned | 0 | 150000 | 0.001 | V |
Voltage |
Permanent I/O elements | |
205 | GSM Cell ID | 4 | Unsigned | 0 | 2147483647 | - | - |
GSM base station ID |
Permanent I/O elements | |
206 | GSM Area Code | 2 | Unsigned | 0 | 65535 | - | - |
Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. |
Permanent I/O elements | |
237 | Network Type | 1 | Unsigned | 0 | 1 | - | - | 0 - 3G
1 - GSM |
Permanent I/O elements | |
67 | Battery Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
68 | Battery Current | 2 | Unsigned | 0 | 65535 | 0.001 | A |
Current |
Permanent I/O elements | |
199 | Trip Odometer | 4 | Unsigned | 0 | 2147483647 | - | m |
Trip Odometer value |
Permanent I/O elements | |
16 | Total Odometer | 4 | Unsigned | 0 | 2147483647 | - | - |
Total Odometer value in meters |
Permanent I/O elements | |
1 | Digital Input 1 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
9 | Analog Input 1 | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
249 | Digital Output 1 Overcurrent | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
641 | ICCID | 22 | ASCII | 0 | 22 | - | - |
Value of SIM ICCID |
Permanent I/O elements | |
70 | PCB temperature | 2 | Signed | -550 | 1150 | 0,1 | °C |
Degrees ( °C ) |
Permanent I/O elements |
Eventual I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
249 | Jamming detection | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Eventual I/O elements | |
250 | Trip | 1 | Unsigned | 0 | 1 | - | - |
0 – trip stop |
Eventual I/O elements | |
255 | Over Speeding | 1 | Unsigned | 0 | 255 | - | km/h |
At over speeding start km/h, at over speeding end km/h |
||
251 | Idling | 1 | Unsigned | 0 | 1 | - | - |
0 – moving |
Eventual I/O elements | |
253 | Green driving type | 1 | Unsigned | 1 | 3 | - | - |
1 – harsh acceleration |
Eventual I/O elements | |
254 | Green Driving Value | 1 | Unsigned | 0 | 255 | acc and braking: 0.01 | G or rad |
Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g). If Green driving source is „GPS“ – harsh cornering value is rad/s*100. If source is „Accelerometer“ – g*100. |
|