Difference between revisions of "Template:FMB2 Supply voltage"
From Wiki Knowledge Base | Teltonika GPS
Simkunas.ma (talk | contribs) (Created page with "{| class="wikitable" |+ ! style="width: 300px; background: black; color: white;" | Description ! style="width: 200px; background: black; color: white;" | Voltage ! style="widt...") |
|||
(3 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | + | <table class="nd-othertables" style="width:60%;"> | |
− | + | <tr> | |
− | + | <th style="width:30%; text-align:center; vertical-align:middle; color: black">Description</th> | |
− | + | <th style="width:15%; text-align:center; vertical-align:middle; color: black">Voltage</th> | |
− | + | <th style="width:15%; text-align:center; vertical-align:middle; color: black">Duration</th> | |
− | + | </tr> | |
− | + | <tr> | |
− | + | <td style="vertical-align:middle">Normal operation</td> | |
− | + | <td> {{{Voltage range|+6 ... +30 V}}} </td> | |
− | + | <td> Unlimited </td> | |
− | + | </tr> | |
− | + | <tr> | |
− | + | <td style="vertical-align:middle">Protection turns on, device turns off</td> | |
− | + | <td style="vertical-align:middle">34 V</td> | |
− | + | <td>Unlimited</td> | |
− | + | </tr> | |
− | + | <tr> | |
− | + | <td style="vertical-align:middle">Maximum voltage</td> | |
− | + | <td style="vertical-align:middle"> < 70 V</td> | |
− | + | <td>Unlimited</td> | |
− | + | </tr> | |
− | + | <tr> | |
− | + | <td style="vertical-align:middle">Maximum voltage impulse</td> | |
+ | <td>{{{maxvol|120}}} V</td> | ||
+ | <td>{{{maxvolDur|10}}} ms</td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br> |
Latest revision as of 11:25, 16 January 2020
Description | Voltage | Duration |
---|---|---|
Normal operation | +6 ... +30 V | Unlimited |
Protection turns on, device turns off | 34 V | Unlimited |
Maximum voltage | < 70 V | Unlimited |
Maximum voltage impulse | 120 V | 10 ms |