Essential fields in ''SMS/Call settings'' are ''Login'' and ''Password''. The login and password are used with every SMS sent to {{{model|FMB640}}}. If login and password are not set, in every SMS sent to {{{model|FMB640}}} device two spaces before command have to be used (<space><space><command>).<br/>Command structure with set login and password:<br/><login><space><password><space><command>, for example: "asd 123 getgps"<br/>Phone numbers have to be written in international standard, using "+" is optional but not necessary (in both cases number will be recognized, but when number is without "+" symbol, IDD Prefix will not be generated, which depends on location of the phone). If no numbers are entered, configuration and sending commands over SMS are allowed from all GSM numbers.<br/>SMS data sending settings allow sending AVL data using binary SMS. AVL data will be sent by SMS only when there is no GPRS connection. This setting does not affect replies to SMS request messages – answers are always sent back to the sender's telephone number.
+
__TOC__
{{{pic_call_settings|[[Image:FMB640_smscall_settings.png|800px|centre]]}}}
+
==SMS commands==
 +
Essential fields in ''SMS/Call settings'' are ''Login'' and ''Password''. The login and password are used with every SMS sent to {{{model|FMB640}}}. If login and password are not set, in every SMS sent to {{{model|FMB640}}} device two spaces before command have to be used '''"<space><space><command>"'''.<br/>Command structure with set login and password:<br/>
 +
'''"<login><space><password><space><command>"''', for example: "asd 123 getgps"<br/>
 +
Phone numbers have to be written in international standard, using "+" is optional but not necessary (in both cases number will be recognized, but when number is without "+" symbol, IDD Prefix will not be generated, which depends on location of the phone). If no numbers are entered, configuration and sending commands over SMS are allowed from all GSM numbers.<br/>SMS data sending settings allow sending AVL data using binary SMS. AVL data will be sent by SMS only when there is no GPRS connection. This setting does not affect replies to SMS request messages – answers are always sent back to the sender's telephone number.
 +
{{{pic_call_settings|[[Image:Sms_call_settings_new.png|800px|centre]]}}}
  
 +
==Incoming Call settings==
 +
{{{pic_incoming|[[Image:Incoming_call_settings.png|300px|right]]}}}
 
''Incoming call settings'' parameter defines device action during incoming call:
 
''Incoming call settings'' parameter defines device action during incoming call:
* <span style=color:#F6A83E>Do Nothing</span>.
+
* <span style=color:#F6A83E>Hangup</span> – automatically hang up an incoming call.
* <span style=color:#F6A83E>Hang-up</span> – automatically hang up an incoming call.
+
* <span style=color:#F6A83E>Report Position</span> – report position to calling number via SMS.
* <span style=color:#F6A83E>Report Position</span> – Report position to calling number via SMS.
 
* <span style=color:#F6A83E>Auto Answer (HF)</span> – Auto answer an incoming call if hands-free device is connected. If hands-free device is not connected, then an incoming call will be hung up.
 
  
When {{{model|FMB640}}} is connected to a hands-free headset, it can call to user defined GSM numbers.
 
 
{{{pic_handsfree|[[Image:FMB640_handsfree.png|300px|right]]}}}
 
 
{{{text_din|''Outgoing Call Trigger'' parameter determines which event will trigger a call. {{{model|FMB640}}} supports eight call trigger settings:
 
* None selected – disables call trigger functionality.
 
* <span style=color:#F6A83E>DIN1</span> – first digital input event triggers a call to user selected GSM number.
 
* <span style=color:#F6A83E>Crash Event</span> – crash event triggers a call to user selected GSM number.
 
* <span style=color:#F6A83E>DIN1</span> and <span style=color:#F6A83E>Crash Event</span> – both events trigger a call to user selected GSM number.
 
* <span style=color:#F6A83E>DIN2</span> – second digital input event triggers a call to user selected GSM number.
 
* <span style=color:#F6A83E>DIN1</span> and <span style=color:#F6A83E>DIN2</span> Event – both events trigger a call to user selected GSM number.
 
* <span style=color:#F6A83E>DIN2</span> and <span style=color:#F6A83E>Crash Event</span> – both events trigger a call to user selected GSM number.
 
* <span style=color:#F6A83E>DIN1</span>, <span style=color:#F6A83E>DIN2</span> and <span style=color:#F6A83E>Crash Event</span> – all events trigger a call to user selected GSM number.<br/><br/>}}}
 
 
{{{model|FMB640}}} works in synchronized GPS time which is UTC+0, with this option customer can configure the time zone and get SMS messages with correct time.
 
  
 
{| class="wikitable" style="border-style: solid; border-width: 0px"
 
{| class="wikitable" style="border-style: solid; border-width: 0px"
Line 31: Line 20:
 
|-
 
|-
 
| style="text-align: left; background: #F6F6FB;"        | [[Image:Bw_nb.png|50px]]
 
| style="text-align: left; background: #F6F6FB;"        | [[Image:Bw_nb.png|50px]]
| style="text-align: left; background: #F6F6FB;"        | SMS login and password and authorized numbers list are used to protect {{{model|FMB640}}} module from unauthorized access. Module accepts messages only from a list of authorized numbers and with proper module login and password. Phone numbers have to be written in international standard using "+" or without using it (in both cases the number will be recognized). If no authorized numbers are entered, module accepts messages from all numbers.
+
| style="text-align: left; background: #F6F6FB;"        | SMS login and password and authorized numbers list are used to protect {{{model|FMB640}}} module from unauthorized access. Module accepts messages only from a list of authorized numbers and with proper module login and password. Phone numbers have to be written in international standard using "+" or without using it (in both cases the number will be recognized). If no authorized numbers are entered, the module accepts messages from all numbers.
 
|}
 
|}

Latest revision as of 09:38, 4 October 2023

SMS commands

Essential fields in SMS/Call settings are Login and Password. The login and password are used with every SMS sent to FMB640. If login and password are not set, in every SMS sent to FMB640 device two spaces before command have to be used "<space><space><command>".
Command structure with set login and password:
"<login><space><password><space><command>", for example: "asd 123 getgps"
Phone numbers have to be written in international standard, using "+" is optional but not necessary (in both cases number will be recognized, but when number is without "+" symbol, IDD Prefix will not be generated, which depends on location of the phone). If no numbers are entered, configuration and sending commands over SMS are allowed from all GSM numbers.
SMS data sending settings allow sending AVL data using binary SMS. AVL data will be sent by SMS only when there is no GPRS connection. This setting does not affect replies to SMS request messages – answers are always sent back to the sender's telephone number.

Sms call settings new.png

Incoming Call settings

Incoming call settings.png

Incoming call settings parameter defines device action during incoming call:

  • Hangup – automatically hang up an incoming call.
  • Report Position – report position to calling number via SMS.


Bw nb.png Please do not set Data Send Number to some cell phone number, because it will not understand binary SMS. When sending a binary SMS to a phone number, which is a server phone number, the server can interpret and understand binary code, so the data can be read and you can view it on the server.
Bw nb.png SMS login and password and authorized numbers list are used to protect FMB640 module from unauthorized access. Module accepts messages only from a list of authorized numbers and with proper module login and password. Phone numbers have to be written in international standard using "+" or without using it (in both cases the number will be recognized). If no authorized numbers are entered, the module accepts messages from all numbers.