FMB630 System info: Difference between revisions

From Teltonika Telematics Wiki
No edit summary
No edit summary
 
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Template:FMB630_System_Settings|model=FMB630|system=FM36_Sys_Settinxgs.jpg}}
{{Template:FMB630_System_Settings|model=FMB630|system=FMB630_Sys_Settings.png}}
[[Category:FMB630 Configuration]]

Latest revision as of 07:37, 17 October 2019

Main Page > EOL Products > FMB630 > FMB630 Configuration > FMB630 System info

System settings have 5 configurable parameters:

  • Sleep mode - where user can turn GPS sleep/deep sleep on or off;
  • Sleep timeout - timer which starts after every sleep condition is met and will end up with device going to sleep mode;
  • Ignition Source sets ignition triggered functionalities to be triggered by:
    • Power Voltage (if voltage is between High Voltage Level and Low Voltage Level the ignition is considered to be turned on);
    • Digital Input 1;
    • Digital Input 2;
    • Digital Input 3;
    • Digital Input 4;
    • Movement (if accelerometer/movement sensor detects movement then ignition is on, if movement stops – ignition is off).